Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 12, 2015 FBO #4979
SOLICITATION NOTICE

66 -- Ultra Focus Digital Radiography System with DXA

Notice Date
7/10/2015
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334517 — Irradiation Apparatus Manufacturing
 
Contracting Office
Department of Health and Human Services, National Institutes of Health, National Heart, Lung and Blood Institute, Rockledge Dr. Bethesda, MD, Office of Acquisitions, 6701 Rockledge Dr RKL2/6100 MSC 7902, Bethesda, Maryland, 20892-7902
 
ZIP Code
20892-7902
 
Solicitation Number
NHLBI-CSB-DE-2015-162-KEW
 
Archive Date
8/8/2015
 
Point of Contact
Kyle Wisor, Phone: 3014023670, Rashida Ferebee,
 
E-Mail Address
Kyle.Wisor@nih.gov, rashida.ferebee@nih.gov
(Kyle.Wisor@nih.gov, rashida.ferebee@nih.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
(1) Action Code: Combined Synopsis/Solicitation (2) Date: July 10th, 2015 (3) Year: 2015 (4) Contracting Office Zip Code: 20892 (5) Classification Code: 6640 (6) Contracting Office Address: 6701 Rockledge Drive Rockledge II Bethesda, MD 20892 (7) Subject/Title: Ultra Focus Digital Radiography System with DXA (8) Proposed Solicitation Number: NHLBI-CSB-DE-2015-162-KEW (9) Closing Response Date: July 24th, 2015 (10) Contact Point: Kyle Wisor, Contract Specialist (11) Contract Award and Solicitation Number: TBD (12) Contract Award Dollar Amount: UKN (13) Contract Line Item Number(s): TBD (14) Contractor Award Date: TBD (15) Contractor Name: TBD (16) Description: The National Institute of Dental and Craniofacial Research (NIDCR) Molecular Biology of Bones and Teeth Section (MBTS), Craniofacial and Skeletal Diseases Branch (CSDB) require an UltraFocus DXA (brand name only) to analyze tissues from mice genetically or surgically engineered to acquire human bone diseases such as osteopenia or bone fracture. (i) "This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued." (ii) The solicitation number is NHLBI-CSB-DE-2015-162-KEW and the solicitation is issued as a request for quote (RFQ). (iii) The solicitation document, the incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-83 effective 02 JUL 2015. (iv) This is a small business set aside. The associated NAICS code is 334517, Irradiations Apparatus Manufacturing, and the small business size standard is 500 Employees. The acquisition is being conducted in accordance with the procedures of FAR Part 12 and FAR Part 13. (v) The Contractor Requirements are listed below: (vi) The Contractor Shall: 1. Provide (quantity 1) Faxitron Ultra Focus DXA, specifications as follows; a. In DXA mode the system automatically calculates BMD, BMC, and lean and fat mass percentages. Both whole body and region of interest (ROI) data is presented. b. Magnification shelf with field of view guides and automatic position detection c. Single click calibration with auto object detect d. One button operation with Automatic Exposure Control (AEC) e. Easily switch between high resolution imaging and DXA mode f. Select from bone, lean and fat tissue maps for detailed ROI DXA analysis g. Images instantaneously displayed on 22" high resolution 2.3MP monitor h. Remote diagnostic and support over the web i. Sample imaging size 10cm x 15cm (4" x 6") j. Pixel pitch 48μm k. Spatial resolution 8μm at 6X geometric magnification l. Energy range 10 - 100kV m. Tube current 0.3mA max (isowatt limited to 12W from 41-60kV) n. Focal spot size, nominal 8μm o. Window filtration 0.25mm Be, tungsten source p. Power 100-240VAC ±10%, 50/60Hz, 150VA q. Dimensions external 23" W x 21" D x 36" H (59cm x 54cm x 90cm) r. Dimensions internal 15.4" W x 15.4" D x 22" H (39cm x 39cm x 56cm s. Ultrafocus Cart t. (1) One year warranty, Installation and (1) One day in-Service training by a factory trained representative (vii) Date of Delivery: Shipping 30 days after receipt of order Place of Delivery: National Institute of Health, NIDCR 30 Convent Drive Building 30, Room 225 Bethesda, MD 20892 (viii) The provision at FAR clause 52.212-1, Instructions to Offerors - Commercial Items, applies to this acquisition. (ix) The provision at FAR clause 52.212-2, Evaluation - Commercial Items, is applicable. The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: Contract award shall be made to the responsible Offeror whose offer, in conforming to this RFQ, provides the overall best value to the Government, technical evaluation factors, and cost considered. The Government's objective is to obtain the highest technical quality considered necessary to achieve the project objectives, with a realistic and reasonable cost. Technical evaluation factors are more important than cost. 1: Technical Evaluation Factor (90 points) The vendor must provide the following product to the specifications below; Provide (quantity 1) Faxitron Ultra Focus DXA a. In DXA mode the system automatically calculates BMD, BMC, and lean and fat mass percentages. Both whole body and region of interest (ROI) data is presented. b. Magnification shelf with field of view guides and automatic position detection c. Single click calibration with auto object detect d. One button operation with Automatic Exposure Control (AEC) e. Easily switch between high resolution imaging and DXA mode f. Select from bone, lean and fat tissue maps for detailed ROI DXA analysis g. Images instantaneously displayed on 22" high resolution 2.3MP monitor h. Remote diagnostic and support over the web i. Sample imaging size 10cm x 15cm (4" x 6") j. Pixel pitch 48μm k. Spatial resolution 8μm at 6X geometric magnification l. Energy range 10 - 100kV m. Tube current 0.3mA max (isowatt limited to 12W from 41-60kV) n. Focal spot size, nominal 8μm o. Window filtration 0.25mm Be, tungsten source p. Power 100-240VAC ±10%, 50/60Hz, 150VA q. Dimensions external 23" W x 21" D x 36" H (59cm x 54cm x 90cm) r. Dimensions internal 15.4" W x 15.4" D x 22" H (39cm x 39cm x 56cm s. Ultrafocus Cart t. (1) One year warranty, Installation and (1) One day in-Service training by a factory trained representative 2: Price (10 points) (x) FAR clause 52.212-3, Offeror Representations and Certifications - Commercial Items, is applicable. An offeror shall complete only paragraphs (b) of this provision if the offeror has completed the annual representations and certificates electronically via http://www.acquisition.gov. If an offeror has not completed the annual representations and certifications electronically at the System for Award Management (SAM) website, the offeror shall complete only paragraphs (c) through (p) of this provision. (xi) FAR clause at 52.212-4, Contract Terms and Conditions - Commercial Items, applies to this acquisition. (xii) FAR clause at 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items, applies to this acquisition. Including the following clauses and Prohibitions: i. 52.223-18, Encouraging Contractor Policies to Ban Text Messaging while Driving (AUG 2011) ii. 52.225-13, Restrictions on Certain Foreign Purchases iii. 52.244-6, Subcontracts for Commercial Items iv. 52.2232-39, Unenforceability of Unauthorized Obligations v. 52.219-6, Notice of Total Small Business Set-Aside vi. 52.222-3, Convict Labor vii. 52.222-19, Child Labor--Cooperation with Authorities and Remedies viii. 52.222-26, Equal Opportunity ix. 52.222-35, Equal Opportunity for Veterans x. 52.222-36, Equal Opportunity for Workers with Disabilities xi. 52.222-37, Employment Reports on Veterans xii. 52.222-50 Combating Trafficking in Persons xiii. 52.232-33, Payment by Electronic Funds Transfer-System for Award Management xiv. 52.222-21, Prohibition of Segregated Facilities (xiii) Additional Contract Requirements: None (xiv) The Defense Priorities and Allocations System (DPAS) and assigned rating are not applicable. (xv) All responses must be received by July 24th, 2015 at 9:00 AM and must reference number NHLBI-CSB-DE-2015-162-KEW. Responses may be submitted electronically to Kyle.Wisor@nih.gov or by U.S. mail to the National Heart, Lung, and Blood Institute, Office of Acquisitions, COAC Services Branch, 6701 Rockledge Drive, Suite 6150B, Bethesda, MD 20892-7902, Attention: Kyle Wisor. Phone: 301-402-3670; Fax responses will not be accepted
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/NIH/NHLBI/NHLBI-CSB-DE-2015-162-KEW/listing.html)
 
Place of Performance
Address: National Institute of Health, NIDCR, Building 30, Room 225, 30 Convent Drive, Bethesda, Maryland, 20892, United States
Zip Code: 20892
 
Record
SN03793232-W 20150712/150710235243-1e20697ed05369e9a15a2473b9db2d09 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.