Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 18, 2015 FBO #4985
MODIFICATION

66 -- Cryogen Free Cryostat

Notice Date
7/16/2015
 
Notice Type
Modification/Amendment
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B130, Gaithersburg, Maryland, 20899-1410, United States
 
ZIP Code
20899-1410
 
Solicitation Number
SB1341-15-RQ-0608
 
Archive Date
8/15/2015
 
Point of Contact
Joni L. Laster, Phone: 3019756205, Patrick K Staines, Phone: (301)975-6335
 
E-Mail Address
joni.laster@nist.gov, patrick.staines@nist.gov
(joni.laster@nist.gov, patrick.staines@nist.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
Amendment I: The purpose of this amendment is revise the minimum required specification on specification 11 and to extend the due date for quotes as follows: Specification 11 is hereby revised as follows: FROM: 11. Must include a cryogenic and vacuum compatible XYZ nanopositioning stage mounted to cryostat cold plate. The stage must have at least 3mm of travel in each direction with 10 nm scale resolution at cryogenic temperatures. The positioners must supply at least 25 g of force in each direction. All wiring inside the cryostat, electrical feedthrough connections, and air-side cabling must be provided. An electronic controller capable of controlling all three axes must be provided. The stage controller must be computer controllable. The footprint of the stage must take up less than one half of the cryostat cold plate area. TO: 11. Must include a cryogenic and vacuum compatible XYZ nanopositioning stage mounted to cryostat cold plate. In two directions (X and Y) the stage must have at least 3mm of travel in each direction with 50 nm scale resolution at cryogenic temperatures and supply at least 25 g of force. In the third direction (Z) the stage must have at least 2.5mm of travel with 50 nm scale resolution at cryogenic temperatures and supply at least 25 g of force. All wiring inside the cryostat, electrical feedthrough connections, and air-side cabling must be provided. An electronic controller capable of controlling all three axes must be provided. The stage controller must be computer controllable. The footprint of the stage must take up less than one half of the cryostat cold plate. The due date for quotes has been extended as follows: FROM: July 14, 2015 at 12 pm ET TO: July 22, 2015 at 12 pm ET All other terms and conditions and minimum required specifications remain unchanged.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/SB1341-15-RQ-0608/listing.html)
 
Place of Performance
Address: 100 Bureau Drive, Gaithersburg, Maryland, 20899, United States
Zip Code: 20899
 
Record
SN03799865-W 20150718/150716235610-b67c5ae75d63d06acc3fb3036f0eb769 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.