Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 15, 2015 FBO #5013
DOCUMENT

65 -- UPS System including installation - Attachment

Notice Date
8/13/2015
 
Notice Type
Attachment
 
NAICS
335999 — All Other Miscellaneous Electrical Equipment and Component Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Activity 8;Commerce Building;300 E. University Ave. Ste. 180;Gainesville FL 32601-3460
 
ZIP Code
32601-3460
 
Solicitation Number
VA24815Q1871
 
Response Due
8/19/2015
 
Archive Date
9/18/2015
 
Point of Contact
BRIAN SHEA
 
E-Mail Address
1-5719<br
 
Small Business Set-Aside
Total Small Business
 
Description
The VA Medical Center in Gainesville, FL has a requirement for an Uninterrupted Power Source (UPS) for a Carl Zeiss LSM 710 Confocal Microscope. To ensure compatibility with the existing equipment and proper functioning thereof, the following are the required specifications: The LSM 710 and LSM 780 systems and ConfoCor 3 come with a main power supply cord and plug, NEMA L 14-30P (2/N/Ground 120/240V/30A), and with the matching main socket outlet. The mains socket outlet must be equipped with a fuse having minimum tripping characteristic C according to IEC/EN 60898. Line voltage 2/N/Ground 240/120 V AC ( ±10 %) Line frequency50...60 Hz Max. current power2 phases at 25 A Phase 1=800 VA Max Phase 2=1600VA max Power Consumption:2100 VA max Power Consumption Ti:Sa Laser 1800 VA max Ti:Sa Laser 2800 VA max OPO600 VA max Class of ProtectionI Type of ProtectionIP 20 Overvoltage categoryII Pollution degree2 Heat emission2000 W max EMC test according to DIN EN 61326-1 (05/2010) 1. Noise emission according to CISPR 11 / DIN EN 55011 (04/2011) 2. Noise immunity according to table 2 (industrial sector) The Ti:Sa laser(s) and OPO need to have a separate electrical connection according to the instructions of the manufacturer. When operating the main switch of the LSM 710 NLO or LSM 780 NLO the Ti:Sa lasers are not switched on or off. Due to the sensitive equipment this UPS will service, quote must include initial start-up and inspection by factory certified technician. Vendors should submit warranty information with quote. Failure to include this information may result in not receiving full credit for same during evaluation. The GE 51002Y UPS has been identified as meeting the above specifications. Vendors may submit offers for other items meeting the above specifications but must include with their offer documentation which clearly establishes in the opinion of the USG Contracting Officer that the item(s) offered meet or exceed all of the stated specifications in all relevant form, fit and function. This solicitation is set-aside for Small Businesses.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANFSGHS/DVANoFSoGHS/VA24815Q1871/listing.html)
 
Document(s)
Attachment
 
File Name: VA248-15-Q-1871 VA248-15-Q-1871_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2251420&FileName=VA248-15-Q-1871-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2251420&FileName=VA248-15-Q-1871-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: MALCOM RANDALL VA MEDICAL CENTER;1601 SW ARCHER RD;GAINESVILLE FL
Zip Code: 32608
 
Record
SN03837463-W 20150815/150813235523-294d1e6f6d905225e43ab05641d647f1 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.