SOURCES SOUGHT
41 -- 180 Ton Water Cooler
- Notice Date
- 8/22/2015
- Notice Type
- Sources Sought
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- Department of the Air Force, Air Force Space Command, 45CONS (Bldg 423), 1201 Edward H White II St MS 7200, Patrick AFB, Florida, 32925-3238, United States
- ZIP Code
- 32925-3238
- Solicitation Number
- FA2521-15-Q-B346
- Archive Date
- 9/15/2015
- Point of Contact
- Yolanda A. Butler, Phone: 3214944395, Cheryl T. Witt, Phone: 321-494-4394
- E-Mail Address
-
Yolanda.Butler@US.AF.MIL, cheryl.witt@us.af.mil
(Yolanda.Butler@US.AF.MIL, cheryl.witt@us.af.mil)
- Small Business Set-Aside
- N/A
- Description
- SOURCES SOUGHT: THIS IS NOT A NOTICE OF REQUEST FOR PROPOSAL BUT INFORMATION AND PLANNING PURPOSES ONLY! The Request for Quotation (RFQ) number is FA2521-15-Q-B346 shall be used to reference any written responses to this source sought. Patrick Air Force Base anticipates a requirement that is being considered under a small business set-aside program. The North American Industry Classification Systems (NAICS) Code proposed 333415. The size standard for NAICS is 750 employees. GSA SIN: 246-42-2 The requirement is for a water-cool frequency 180 ton 460/3/60 water cooled Optimus(TM) Adaptive frequency drive chiller/water cooled. Salient Characteristics: Chiller must come with compressors driven by variable frequency speed technology and use R-134a refrigerant. Refrigerant-- R-134a. With Circuit breaker and LON interface Flexible Condenser and Evaporator connections/piping made to order (upon award of contract) Variable frequency compressor 10 year parts/labor/refrigerant warranty Field factory start-up Chiller is UL listed to U.S. and Canadian safety standards Chiller complies with ASME Pressure Vessel Code. Insulate the evaporator and water boxes, suction line, and motor housing. Capacity (tons) 179.70 Unit power (kW) 108.40 Efficiency (kW/ton) 0.603 NPLV (kW/ton) 0.407 A weighted sound pressure (AHRI) (dBA) 83 Refrigerant charge (lb) 490.0 Evap leaving temp (F) 44.00 Evap entering temp (F) 54.00 Evap flow rate (gpm) 429.60 Evap pressure drop (ft H2O) 11.40 Evap fouling factor (hr-sq ft-deg F/Btu) 0.00010 Evap fluid concentration (%) 0.00 Evap fluid freeze point (F) 32.00 Max evap flow rate (gpm) 941.00 Saturated evap temp (F) 41.70 Cond entering temp (F) 85.00 Cond leaving temp (F) 95.00 Cond flow rate (gpm) 506.30 Cond pressure drop (ft H2O) 14.50 Cond fouling factor (hr-sq ft-deg F/Btu) 0.00025 Cond fluid concentration (%) 0.00 Min cond flow rate (gpm) 208.00 Press drop at min cond flow (ft H2O) 2.90 Max cond flow rate (gpm) 850.00 Saturated cond temp (F) 98.20 Run load amps/AFD input amps (A) 184.10 Min circuit ampacity (A) 230.20 Max overcurrent protection (A) 400.00 Length (in) 142.600 Width (in) 64.900 Height (in) 74.400 Rated capacity (AHRI) (tons) 190.70 Rated efficiency (AHRI) (kW/ton) 0.625 IPLV (kW/ton) 0.417 What is the purpose of the item(s): Water cooled chillers and air cooled chillers are refrigeration systems used to cool fluids or dehumidify air in both commercial and industrial facilities. 45 CONS is interested in any size business that is capable of meeting this requirement. The government is also interested in all small businesses including (8(a), Historically Underutilized Business Zone, Service Disabled Veteran Owned Small Businesses (SDVOSB), or, if applicable based on NAICS code, Economically disadvantaged women-owned small business (EDWOSB) Women Owned Small Businesses (WOSB) that are interested in performing this requirement. The government requests interested parties submit a brief description of their company's business size (i.e. annual revenues and employee size), business status (i.e., 8(a), Historically Underutilized Business Zone, or SDVOSB, WOSB, EDWOSB, or small business) anticipated teaming arrangements, and a description of similar services offered to the Government and to commercial customers. Any responses involving teaming agreements should delineate between the work that will be accomplished by the prime and the work accomplished by the teaming partners. The Government will use this information in determining its small business set-aside decision." As stipulated in FAR 15.201, responses to this notice are not considered offers and cannot be accepted by the Government to form a binding contract. No solicitation exists; therefore, do not request a copy of the solicitation. The decision to solicit for a contract shall be solely within the Government's discretion. Any information submitted by respondents to this sources sought synopsis is voluntary. This sources sought notice is not to be construed as a commitment by the Government, nor will the Government reimburse any costs associated with the submission of information in response to this notice. Respondents will not be individually notified of the results of any government assessments. The Government's evaluation of the capability statements received will factor into whether any forthcoming solicitation will be conducted as a full and open competition or as a set-aside for small businesses, or any particular small business designation (e.g. SDVOSB, HUBZone, 8(a), WOSB, VOSB, etc.). All interested firms shall submit a capabilities package that explicitly demonstrates company capabilities-indicating examples of commercial sales-and product specifications related to this effort. Also indicate if you are the manufacturer, or provide the name and size of the manufacturer of the product(s) you will be supplying. Respondents are further requested to indicate their status as a Foreign-owned/foreign-controlled firm and any contemplated us of foreign national employees on this effort. Include in your capabilities package your DUNS, Cage Code, System for Award Management expiration date, GSA contract number and expiration (if applicable), and any related specifications/drawings. Responses may be submitted electronically to the following e-mail address: 45cons.lgcb.e-bids@us.af.mil; by mail to 45 CONS/LGCB, Attn: FA2521-15-Q-B346, 1201 Edward H. White II Street, Bldg. 423, Room N206, Patrick AFB, FL 32925-3238; or by Fax to 321-494-1843. RESPONSES ARE DUE NO LATER THAN 31 AUG 15. It does not constitute a solicitation and/or quote and is not to be construed as a commitment by the Government.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFSC/45CONSb423/FA2521-15-Q-B346/listing.html)
- Place of Performance
- Address: 46 CES/CEOIH, Patrick AFB, FL 32925, Patrick AFB, Florida, 32925, United States
- Zip Code: 32925
- Zip Code: 32925
- Record
- SN03851325-W 20150824/150822233357-89069fa3cfb324ba4fcc82a2e9b7ab49 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |