SOURCES SOUGHT

J -- Hitachi SF6 Gas Circuit Breaker (1972) type HVD 145 40 Maintenance Service

Notice Date
8/26/2015
 
Notice Type
Sources Sought
 
NAICS
335313 — Switchgear and Switchboard Apparatus Manufacturing
 
Contracting Office
Bureau of Reclamation Pacific Northwest Region Snake River Area Office East 470 22nd Street Heyburn ID 83336 US
 
ZIP Code
00000
 
Solicitation Number
R15PS01709
 
Response Due
8/28/2015
 
Archive Date
9/12/2015
 
Point of Contact
Moffett, Michael
 
Small Business Set-Aside
Total Small Business
 
Description
This notice is being issued to help determine the availability of qualified businesses technically capable of meeting the Government requirement and to determine the method of acquisition, including whether a small business social-economic set-aside is possible. This notice is not to be construed as a commitment by the Government to issue a solicitation or ultimately award a contract. Responses will not be considered as proposals or quotes. No award will be made as a result of this notice. The Government will not be responsible for any costs incurred by the respondents to this notice. The notice is for research and information purposes only. The Bureau of Reclamation (BOR) has a requirement for a Hitachi SF6 Gas Circuit Breaker (1972) type HVD 145 40KA 2000A to be serviced. Acceptable timing for an open cycle is no more than 33ms. During recent diagnostics testing, timing for an open cycle was approximately 280ms. After operating the breaker several times, the timing was reduced to 106ms. After BOR personnel cleaned components of the operating mechanism, the timing was reduced further to 72ms, however, well above the maximum open cycle time. It appears the pin in the pilot valve is contaminated with dirt and grease preventing the breaker from operating within acceptable time limits. The Bureau of Reclamation requires the breaker to be serviced and restored to the manufacture ¿s operating specifications. Specifically, BOR requires the following tasks to be completed: * Lubricate all linkages * Rebuild oil dashpot * Rebuild air system to include all of the pilot/charging valves * Train BOR electricians to complete the following tasks in accordance with Hitachi Maintenance Manual. * lubricate all linkages * rebuild oil dashpot * rebuild air system including pilot/charging valves. The solicitation number will be R15PS01709. The solicitation, amendments, and any other information will be issued in electronic format only and will be available on or about September 1, 2015 through the Federal Government Electronic Posting System, www.fedbizopps.gov. No additional media (CD-ROM, floppy disk, faxes, email, etc.) will be provided. Paper solicitations will not be available. This notice is being issued to help determine the availability of qualified businesses technically capable of meeting the Government requirement and to determine the method of acquisition, including whether a small business social-economic set-aside is possible. This notice is not to be construed as a commitment by the Government to issue a solicitation or ultimately award a contract. Responses will not be considered as proposals or quotes. No award will be made as a result of this notice. The Government will not be responsible for any costs incurred by the respondents to this notice. The notice is for research and information purposes only. The associated North American Industrial Classification System (NAICS) code for this procurement is 335313 ¿ Switchgear and Switchboard Apparatus Manufacturing with an associated small business size standard of 750 employees. The Product Service Code (PSC) code is J061. All businesses with the capability and availability to perform the requirement under the applicable NAICS code are invited to submit a response to this notice. The information requested is: 1. Company name, address, DUNS number, and point of contact name and email address 2. Business size and small business size classification if applicable (e.g. 8(a), HubZone, Veteran Owned, Woman Owned, etc.) 3. Information that would demonstrate that your business has the capability and resources to meet the specifications of the requirement as described. 4. 30 day delivery is preferred; therefore please indicate whether your company would be able to meet such a deadline 5. Your intent to submit a quote if a solicitation is issued All responses to this Sources Sought notice shall be submitted electronically (via email) to Michael T. Moffett at mmoffett@usbr.gov no later than Monday, August 31, 2015 at 5:00 p.m. EST.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/090f7991561e3c46d737b4800480a8d9)
 
Record
SN03856458-W 20150828/150826235423-090f7991561e3c46d737b4800480a8d9 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.