H -- Hydrostatic Test of Burster Detonation Vessel

Notice Date
8/28/2015
 
Notice Type
Modification/Amendment
 
NAICS
541380 — Testing Laboratories
 
Contracting Office
Department of the Army, Army Contracting Command, ACC-APG-TENANT CONTRACTING DIV, 6001 COMBAT DR, ABER PROV GRD, Maryland, 21005-1846, United States
 
ZIP Code
21005-1846
 
Solicitation Number
W91ZLK-15-T-0291
 
Archive Date
9/30/2015
 
Point of Contact
Amy DuBree, Phone: 4438614743
 
E-Mail Address
amy.c.dubree2.civ@mail.mil
(amy.c.dubree2.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
Hydrostatic Test of Burster Detonantion Vessel, see attachments. Site Visit being held on 9 SEP 2015, must follow instructions attached. Q&A: Questions: Would like to know the diameter of the sphere? Answer: Inner sphere diameter is 47.24 inches. Question: Will the government supply the water for the hydrostatic testing? Answer: Yes Question: Can the testing contractor use 'Process Cooling Water' from within the building? Answer: Not sure what "process cooling water" is but we have water in the building that can be used. Question: Who is responsible for water disposal after the testing is complete? Answer: Government Question: Before the hydro/pressure test would it be possible to evaluate the Vessel in accordance with the Pressure Vessel code (API 510)? Answer: Yes Question: Section 3.0, Requirements Para 3.2 - "Contractor shall provide final written inspection report and certification of the BDV." Q: What is the desired standard or reference that the BDV is to be certified to, at, for, or in accordance with? Answer: The certification is stating the BDV structural integrity meets the hydrostatic testing parameters; however, the final written inspection report shall also state this thereby can delete the certificate. Question: Would the operations manual be available for the Burster Detonation Vessel so we can evaluate what the high pressure fittings are? Answer: Yes, to the awarded contractor. Question: List of Items, Schedule of Requirements, Scope of Work, Terms of Reference, Bill of Materials required. Answer: Refer to Combined Synopsis/Solicition in this posting. Question: Soft Copy of the Tender Document through email. Answer: Refer to Combined Synopsis/Solicitation in this posting. Question: Names of the countries that will be eligible to participate in this tender. Answer: Refer to Trade agreement, http://farsite.hill.af.mil/vffara.htm Question: Information about the Tendering Procedures and Guidelines Answer: Refer to Combined Synopsis/Solicitation in this posting. Question: Estimated Budget for this purchase? Answer: Funding values are for official use only and will not be disclosed. Question: Any Extension of Bidding Deadline? Answer: Not required Question: Any Addendum or Pre Bid meeting minutes? Answer: Not anticipated.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/e9c9d35c4debef83289cb9294c43e62e)
 
Place of Performance
Address: Edgewood Chemical and Biological Center, AberdeenProving Ground, Maryland, 21010, United States
Zip Code: 21010
 
Record
SN03861458-W 20150830/150828235402-e9c9d35c4debef83289cb9294c43e62e (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.