Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 04, 2015 FBO #5033
SOURCES SOUGHT

49 -- Intent to Award Sole Source - Blast Room

Notice Date
9/2/2015
 
Notice Type
Sources Sought
 
NAICS
332999 — All Other Miscellaneous Fabricated Metal Product Manufacturing
 
Contracting Office
Department of the Air Force, Air Education and Training Command, Maxwell AFB Contracting Squadron, 50 LeMay Plaza South, Bldg 804, Maxwell AFB, Alabama, 36112-6334
 
ZIP Code
36112-6334
 
Solicitation Number
Bailey-F2XTB95238AW02
 
Archive Date
9/22/2015
 
Point of Contact
Joshua K. Bailey, Phone: 334-953-5861
 
E-Mail Address
joshua.bailey@us.af.mil
(joshua.bailey@us.af.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
This notice of intent is not a request for quotes and no solicitation is available. A determination not to compete the proposed procurement based upon responses to this notice is solely within the discretion of the Government. The 42nd Contracting Squadron at Maxwell AFB, AL hereby gives notice of intent to award a sole source contract to Pauli Systems, Inc., 1820 Walters Court, Fairfield, CA, 94533-2759. The North American Industry Classification System (NAICS) Code is, 332999 and the small business size is, 750 employees. As implemented by the Federal Acquisition Regulation (FAR) 13.501(a)(1), acquisitions conducted under simplified acquisition procedures are exempt from the requirements in Part 6. Capability statements received by the response date of this announcement may be considered by the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. Pauli Systems, Inc. will provide a Pauli Systems Turn Key Standard Plastic Media Blast Room. This blast room will be utilized to clean, strip and remove paint from aircraft components and support equipment for inspection, repair and refurbishment to ensure sustainability of critical assets. The existing Pauli Systems Standard Blast Room Cartridge Filter Dust Collector was replaced in September 2013, under contract number FA3300-13-P-0094. This dust collector is designed to run with other Pauli Systems blast room components. Pauli Systems holds proprietary rights for all of their products, and explained that any attempt to connect the dust collector to another manufacturer's blast room will nullify the manufacturer's s well as increase the risk of potential system failure, to include developing leaks of hazardous material. Along with the increased safety risks, Pauli Systems construed that attempting to use their product with another manufacturer's system would degrade system performance and cause premature wear on all components, as their design incorporates a much higher rate of airflow than found in other blast room systems. This requirement will include but is not limited to: •A. Standard Blast Room •1. Blast enclosure, 15'Wx10'Hx18'L, 12 gauge walls, 14 gauge ceilings. •2. Lighting for approximately 100 ft.-candles @ 36" from floor, light bulbs will be accessible from the exterior of the blast booth. •3. One (1) set of swing type equipment doors and two metal personnel doors with view windows and safety interlocks. •4. External Work Station. •5. One (1) RAM 22 (Single operator) Blast/Reclaim system and clean media storage hopper each with: •a. Cyclone Separator. •b. 16 cubic foot Storage Hopper. •c. Media Recovery Blower. •d. RAM 11 Blast Machine. •e. 1/2" bore Nozzle. •f. Lightweight hose systems consisting of 50 feet of 1-1/4" ID x 1-7/8" OD media hose and 16 feet of 3/4" ID x 1-1/2" OD "whip" hose for operator ease and maneuverability. •g. RC150P Feather Touch Remote Control System with Lo-Profile control handle and automatic safety. •h. 6-cubic foot Pressure Vessel with 60 degree conical bottom for total media discharge. •i. Fluidized Section at pressure vessel discharge for smooth, even, repeatable media flow. •j. M70 Media Metering Valve with straight through design, featuring horizontal stainless steel metering discs for precise & repeatable media flow, and thread less cleanout port for fast access to the top of the valve. •k. Air Inlet Control Assembly with moisture separator, air pressure regulator, and gauge. •l. Pop-up Filler Valve for automatic refill on every exhaust cycle. •6. High volume 1-1/4" internal and external piping with 1-1/2" inlet valve. •7. One (1) AccuFlow Precision Media Control Valve. •8. Above grade, clog free, full floor pneumatic recovery system. •a. One (1) fully automatic and programmable rotary selector for consentient and efficient media recovery. •b. Ramp and Skirt Kit for equipment entry and a "clean look" finish. •c. Personnel door entry platform for safety and ease of entry. •9. Associated equipment including hoses, CO monitor with visual alarm and horn. •10. Control Panels with disconnect switches, motor starters, and safety interlocks. •11. One (1) Operator Safety Packages with, breathing air hose, helmet, gloves and apron. •12. Two (2) breathing and process air connection points on booth. •13. Hoses and other hardware as required. •14. One (1) Pauli Systems FBN-8 Fan Blast Nozzle, with Autoloc feather touch control. •15. One (1) Pauli Systems FBN-6 Fan Blast Nozzle, with Autoloc feather touch control for use with the external work station. •B. Equipment Installation, Setup, Start-Up, and Training •1. System start-up, testing, and appropriate adjustments. Operator training of the strip process, equipment operation, equipment servicing to increase product life, troubleshooting, and equipment maintenance to be conducted immediately following equipment installation. •2. Provide all labor, material, supervision, and transportation to satisfy the requirement. •C. Dismantling •1. Dismantling of all parts and equipment (excluding the dust collector) associated with the current blast room from Maxwell AFB, AL. Delivery: All items for this requirement are estimated to be delivered within 120 days after the award of the contact. Firms responding to this synopsis are asked to provide the following information in their initial response: company's full name, business size, address, point of contact, and a clear indication as to whether or not they can provide the item the government is seeking. Final responses to this notice will be due on 12:00pm, Central Standard Time (CST), on 7 Sept 2015. As industry may expect to see portions of submitted information in future solicitations, portions of the response containing proprietary information should be clearly marked as such. Information submitted will not be returned to the respective respondents. Oral submissions of information are not acceptable and will not be accepted in response to this notice. Points of contact for this synopsis are as follows: SSgt. Joshua Bailey, joshua.bailey.5@us.af.mil Contract Specialist, Phone: (334)-953-1549; Fax (334) 953-3543 and Marcus Abram, marcus.abram@us.af.mil, Team Lead, Phone: 334-953-3526. Please use this contact information for any questions.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AETC/MaxAFBCS/Bailey-F2XTB95238AW02/listing.html)
 
Place of Performance
Address: 50 Lemay Plaza S., Maxwell AFB, Alabama, 36112, United States
Zip Code: 36112
 
Record
SN03867541-W 20150904/150902235410-55c898190b779ad50db3a7da5bd79f34 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.