SOLICITATION NOTICE

Y -- Electrical and Data Wire Install - Solicitation

Notice Date
9/25/2015
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, St. Paul, Attn: CEMVP-CT, 180 East Fifth Street, St. Paul, Minnesota, 55101-1678, United States
 
ZIP Code
55101-1678
 
Solicitation Number
W912ES-15-T-0176
 
Archive Date
10/17/2015
 
Point of Contact
Jesse Onkka, Phone: 6512905444, Shamron J. Richardson, Phone: 6512905415
 
E-Mail Address
Jesse.L.Onkka@usace.army.mil, shamron.j.richardson@usace.army.mil
(Jesse.L.Onkka@usace.army.mil, shamron.j.richardson@usace.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Solicitation Scope of Work for Installation of Electrical & Data For Ace It Cubicle 7E19A The following describes the services to be performed for US Army Corps of Engineers District located at 180 Fifth Street East Suite700 St. Paul, MN 55101. All work shall comply with Federal State and Local building codes. Data The Horizontal Cabling Subsystem should be constructed as follows: -Contractor will provide and install one (1) dual port furniture outlet. -The contractor shall run new Category 6A Shielded Plenum Rated - data cable from each port on the outlet to the patch closet. -At same time of running data cables for cubicle outlets the contractor shall run two additional data cables which will be coiled up above ceiling tile leaving 12 feel of extra length for future usage -The cables will be installed from the outlet jack, through contractor provided stub out, along the plenum ceiling area using contractor provided conduit sleeves when needed to the IT Closet 7NE. A horizontal run of approximately 175 feet. - Contractor will follow existing cable trays pathways when present and support the cable with hangers, structural support and cable ties when needed. The Work Location Cabling Subsystem will be constructed as follows: -Contractor will terminate the data cables on Category 6A jacks at the workstation. -Patch cords for the terminals are not included in this proposal. The Equipment Room and Telecommunications Closet Subsystem will be constructed as follows: -The data cable will terminate on the existing RJ45 port patch panel hardware in the IT Closet. Contractor will provide Testing of all wiring and connectors include testing for: -Attenuation, Continuity, Polarity, Reversals, Shorts and Grounds Electrical -Contractor will install electrical service to two existing outlets in furniture system raceway off a current ceiling feed panel located above cubicle 7E19A -Contractor needs to provide copy of driver's license and social security number of personnel conducting the work four business days prior to arrival onsite. Identification information shall be provided Duane Isle 651-290-5226 -For Utilization of building freight elevators, loading dock, and alley access please coordinate 72 hours in advance with Facilities Specialist Duane Isle 651-290-5226
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA37/W912ES-15-T-0176/listing.html)
 
Record
SN03903892-W 20150927/150925235134-b9dda9e63f588a5db5c36f80fc085cc2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.