Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 30, 2015 FBO #5059
SOLICITATION NOTICE

Z -- Statue of Liberty National Monument and Ellis Island Repair Damage to Multiple Park Buildings and Landscapes - J&A

Notice Date
9/28/2015
 
Notice Type
Justification and Approval (J&A)
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Interior, National Park Service, NPS - All Offices, 12795 West Alameda Parkway, Post Office Box 25287, Denver, Colorado, 80225-0287
 
ZIP Code
80225-0287
 
Solicitation Number
P14PD00557
 
Archive Date
10/28/2015
 
Point of Contact
Victoria Nosal, Phone: (303) 969-2203
 
E-Mail Address
victoria_nosal@nps.gov
(victoria_nosal@nps.gov)
 
Small Business Set-Aside
N/A
 
Award Number
P14PD00557
 
Award Date
3/20/2014
 
Description
Justification & Approval for other than full and open competition This is an in-scope construction contract modification under an open construction contract task order P14PD00557 (expires December 3, 2015) awarded under a now expired Base IDIQ contract F09PC60441 (expired June 9, 2015). RFP 40, Relocate Fire Alarm Control Panels was needed because the existing fire alarm control room was repurposed to be one of the new Main Immigration Building electrical rooms. The fire alarm controls needed to be relocated in order to provide adequate space for the new electrical equipment. Item 2: RFP 57 - Provide Concessions Equipment The Statue of Liberty/Ellis Island National Monument is contractually obligated to provide the concessionaire with a walk in freezer, refrigerator and cooler. The existing equipment was destroyed in flooding caused by Hurricane Sandy. This modification is to replace the equipment lost in the flood. Item 3: RFP 59 - Provide Floor Drain in Fire Pump Room Because of post Hurricane Sandy, new equipment constructed at Ellis Island is required to be located two feet above the design flood level established by FEMA. Therefore, one of the fire pumps that serve Ellis Island was relocated from the first floor to the second floor of the Bakery and Carpentry Building. Because code requires that a fire pump room must have a floor drain and because the new space did not have a floor drain, the contract must be modified to add one in this space.   Item 4: RFP 60 - Provide Fire Dampers in MIB Basement Electrical Rooms The two new electrical rooms located in the Main Immigration Building basement are required to be fire rated because of their use. Because they are fire rated, code requires that air supply ducts leaving the rooms have fire dampers. Dampers were not indicated in the construction drawings. This modification will be to install dampers in new ducts and ensure that existing dampers are operable.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOI/NPS/APC-IS/P14PD00557/listing.html)
 
Place of Performance
Address: Statue of Liberty Park and Ellis Island, New York, New York, 10004, United States
Zip Code: 10004
 
Record
SN03906387-W 20150930/150928235355-766f582671fa4bfc72bd041000c116a6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |