Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 17, 2015 FBO #5076
SOLICITATION NOTICE

13 -- 1,000 EA ARMD Igniter Assemblies

Notice Date
10/15/2015
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
325920 — Explosives Manufacturing
 
Contracting Office
ACC-RSA-LEAD - (SPS), ATTN: AMSAM-LE-KO, 1 Overcash Avenue, Bldg 2, Chambersburg, PA 17201-4152
 
ZIP Code
17201-4152
 
Solicitation Number
W911N2-15-Q-0003
 
Response Due
10/27/2015
 
Archive Date
12/14/2015
 
Point of Contact
Kevin Duffy, 717 267-8938
 
E-Mail Address
ACC-RSA-LEAD - (SPS)
(kevin.duffy4@us.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This is a Request for Quotation (RFQ) W911N2-15-Q-0003 for the purchase of 1,000 EAARMD Igniter Assemblies commensurate with the requirement Purchase Description and ARMD Igniter Drawing, as attached. This solicitation is a 100% Small Business Set Aside. The anticipated award will be a Firm Fixed Price Contract; the award will be made based on the lowest price; technically acceptable. The North American Industry Classification System (NAICS) code is 325920. The SB size standard for this code is 750 Employees. The following are required: CLIN 0001 -one thousand (1000) EA new igniter assemblies that meet the attached Purchase Description and ARMD Igniter Drawing, 5813-330-01 REV 0, also attached. All items shall be delivered to Letterkenny Army Depot, Chambersburg, PA 17201. Provision at FAR 52.212-1, Instruction to Offerors Commercial Items (APE 2014) applies to this acquisition. The following addenda is provided to this provision: Request for Quotation should be submitted and shall contain the following information: Solicitation Number; Time Specified for receipt of offers; Name; Address; Telephone Number of Offeror; Terms of the expressed warranty; Price, Payment terms, Any discount terms, FOB destination, CAGE code, DUNS number, Tax ID number and acknowledgement of all solicitation amendments. Quotes must indicate quantity, unit price and total amount. Offerors that fail to furnish the required information, or reject the terms and conditions of the solicitation may be excluded from consideration. Offerors shall electronically complete FAR 52.212-3 Offeror Representation and Certification- Commercial Items at www.sam.gov. FAR 52.204-7 System for Award Management (JUL 2013) FAR 52.204-13 System for Award Management Maintenance (JUL 2013) FAR 52.204-16 Commercial and Government Entity Code Reporting (NOV 2014) FAR 52.204-17 Ownership of Control of Offeror (NOV 2014) FAR 52.204-18 Commercial and Government Entity Code Maintenance (NOV 2014) FAR 52.204-19 Incorporation by Reference of Representations and Certifications (DEC 2014) FAR 52.212-1 Instructions to Offerors -- Commercial Items (APR 2014); FAR 52.212-3 Offerors Representations and Certifications-Commercial Items (MAR 2015) ALT I; FAR 52.212-4 Contract Terms and Conditions-Commercial Items (MAY 2015); FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items (APR 2015) (DEVIATION) FAR 52.219-6 Notice of Total Small Business Set Aside (NOV 2011) FAR 52.219-28 Post-Award Small Business Program Representation (JUL 2013) FAR 52.222-3 Convict Labor (June 2003); FAR 52.222-19 Child Labor-Cooperation with Authorities and Remedies (JAN 2014); FAR 52.222-21 Prohibition of Segregated Facilities (APR 2015); FAR 52.222-26 Equal Opportunity (APR 2015); FAR 52.222-35 Equal Opportunity for Veterans (JUL 2014) FAR 52.222-36 Affirmative Action for Workers with Disabilities (JUL 2014) FAR 52.222-50 Combating Trafficking in Persons (MAR 2015); FAR 52.223-15 Energy Efficiency in Energy-Consuming Products (DEC 2007) FAR 52.223-18 Contractor Policy to Ban Text Messaging While Driving (AUG 2011); FAR 52.232-33 Payment by Electronic Funds Transfer-System for Award Management (JUL 2013) (31 U.S.C. 3332); FAR 52.233-3 Protest after Award (AUG 1996); FAR 52.233-4 Applicable Law for Breach of Contract Claim (OCT 2004) FAR 52.247-34 F.o.b Destination (NOV 1991); FAR 52.252-1 Solicitation Provisions Incorporated by Reference (FEB 1998); FAR 52.252-2 Clauses Incorporated by Reference (FEB 1998); FAR 52.252-5 Authorized Deviations in Provisions (APR 1984); FAR 52.252-6 Authorized Deviations in Clauses (APR 1984) DFARS 252.203-7000 Requirements Relating to Compensation of Former DoD Officials (SEP 2011) DFARS 252.203-7002 Requirement to Inform Employees of Whistleblower Rights (SEP 2013); DFARS 252.203-7005 Representation Relating to Compensation of Former DoD Officials (NOV 2011); DFARS 252.204-7004 Alternate A, System for Award Management (FEB 2014); DFARS 252.204-7012 Safeguarding of Unclassified Controlled Technical Information (NOV 2013); DFARS 252.225-7001 Buy American and Balance of Payments Program (NOV 2014); DFARS 252.232-7003 Electronic Submission of Payment Requests (JUN 2012); DFARS 252.232-7006 Wide Area Workflow Payment Instructions ( MAY 2013); DFARS 252.243-7001 Pricing Of Contract Modifications (DEC 1991); DFARS 252.247-7023 Transportation of Supplies by Sea (APR 2014) Facsimile and email offers will be accepted. Point of contact for this solicitation is Kevin Duffy, 717-267-8938, FAX: 717-267-9834, e-mail kevin.a.duffy4.civ@mail.mil. IMPORTANT NOTICES: 1) RFQ submission must be in accordance with solicitation; 2) Offerors must be registered in the System for Award Management (SAM) to be eligible for award. 3) All Amendments, if applicable, must be acknowledged; 4) Questions concerning this notice should be submitted in writing to the Point of Contact as indicated in this announcement; 5) Contractors who respond directly to ASFI will not be considered responsive. 6) The closing period for questions is 19 OCT 2015, 10:00 A.M Eastern Standard Time. Questions received after this time and date will be answered at the sole discretion of the Government; 7) Response Time - Request for Quotation will be accepted at Letterkenny Army Depot, Chambersburg, PA 17201 not later than 10:00 A.M. Eastern Daylight Time on 27 OCT 2015. All quotes must be marked with RFQ number and title and accompanied with a signed/dated copy of this combined synopsis/solicitation and all amendments. Email quotes will be accepted. Electronic funds transfer (EFT) is the method of payment. This can be established through Wide Area Work Flow (WAWF). 52.212-2EVALUATION--COMMERCIAL ITEMS (OCT 2014) (a)The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: Lowest Price Technically Acceptable (b)A written notice of award or acceptance of an offer, mailed or otherwise furnished to the successful offeror within the time for acceptance specified in the offer, shall result in a binding contract without further action by either party. Before the offer's specified expiration time, the Government may accept an offer (or part of an offer), whether or not there are negotiations after its receipt, unless a written notice of withdrawal is received before award. (End of provision) ADENDUM TO FAR 52.212-2 Technical acceptability shall be based on compliance with the required technical components identified in Attachment I. Offerors must provide sufficient information and detail to demonstrate the offered new igniter assemblies meet or exceed the specifications listed in Attachment I. All offers that do not clearly establish technical acceptance in compliance with the above will be removed from further consideration. (End of clause) L2. AMC-Level Protest Program If you have complaints about this procurement, it is preferable that you first attempt to resolve those concerns with the responsible contracting officer. However, you can also protest to Headquarters, AMC. The HQ, AMC-Level Protest Program is intended to encourage interested parties to seek resolution of their concerns within AMC as an Alternative Dispute Resolution forum, rather than filing a protest with the General Accounting Office (GAO), or other external forum. Contract award or performance is suspended during the protest to the same extent, and within the same time periods, as if filed at the GAO. The AMC protest decision goal is resolve protests within 20 working days from filing. To be timely, protests must be filed within the periods specified in Federal Acquisition Regulation 33.103. Send protests (other than protests to the contracting officer) to: Protest to HQ, AMC shall be filed at: Headquarters U.S. Army Materiel Command Office of Command Counsel 4400 Martin Road Rm: A6SE040.001 Redstone Arsenal, AL 35898-5000 Fax: (256) 450-8840 Packages sent by FedEx or UPS should be addressed to: Headquarters U.S. Army Materiel Command Office of Command Counsel 4400 Martin Road Rm: A6SE040.001 Redstone Arsenal, AL 35898-5000 Fax: (256) 450-8840 The AMC-level protest procedures are found at: www.amc.army.mil/amc/command_counsel/protestlink.htm If internet access is not available contact the contracting officer or HQ, AMC to obtain the AMC-Level Protest Procedures. L21 PACKING SLIPS All deliveries shall include a packing list that references the contract/order number. This applies to packing slips from 3rd party/drop ship vendors. Failure to include the contract/ order number in the packing list will result in payment delays and the possibility of rejected deliveries. Attachment 1 LETTERKENNY MUNITIONS CENTER PURCHASE DESCRIPTION FOR ARMD IGNITER ASSEMBLY 1.REQUIREMENTS: Letterkenny Munitions Center has the requirement for one thousand (1000) each new igniter assemblies with the following standard features and options: 1.1SPECIFICATIONS: 1.1.1See attached drawing 15813-330-01 REV 0 1.1.2All igniters must be fabricated according to the specifications on the attached drawing. No substitutes or equals may occur. 1.1.3Igniter leads will be fabricated utilizing 20 gauge insulated copper wire with a heavy duty 22 gauge nichrome wire as the heating element and spring lock terminal connectors. The igniter body will be sheathed in 4 mil poly tubing. Igniters will be assembled and packed with an easily removable shorting clip of the manufacturer's choice, installed between the spring lock terminal connectors that will insure a positive shunt to the circuit. 1.1.4Ignition charge will consist of 10.5 grams of high specific impulse composite propellant with exceptional reliability. Functional characteristics include a seven second burn period with a 14 inch flame plume. 1.1.515 year shelf life expectancy as determined by the date of the manufacturer. Igniters are considered Type II shelf-life items that have an assigned shelf-life of 15 years from the date of manufacture. 1.1.6The igniter will function when a 5 to 12 VDC, (8 Amp) current charge is applied across the bridge wire. 1.1.7Hazard classification of 1.4S and a Department of Transportation Special Permit of Authorization for transport will be determined by the Defense Ammunition Center. 1.1.8Packaging will be in accordance with the United Nations (UN) Performance Oriented Packaging for Dangerous Goods, Packing Group II -- 4G/Y certified fiberboard boxes for shipment and handling. Igniters must be individually packaged for shipping, delivery and consumption in an EMR shielded inner package (Method Code GX, Method 41 conforming to MIL-DTL-117). 1.1.9All igniters will be distinguished by utilizing the standard LOT numbering system. A LOT numbering system is an alpha-numeric designator, systematically assigned to each ammunition LOT at the time of manufacture that uniquely identifies the particular ammunition LOT throughout its lifecycle. A LOT is defined as a quantity of homogeneous ammunition items manufactured by one activity under uniform conditions with identical stock materials and designed to function in a uniform manner (See MIL-STD-1168C). LOT numbers will be included on unit pack, intermediate container and over pack, individual igniters do not require marking. 1.1.10A copy of the Material Safety Data Sheet (MSDS) 1.1.11Markings: Shall be accomplished by any means that provides the required degree of legibility and durability. The markings may be applied by tagging, stenciling, machine printing or labeling (using preprinted labels). Lettering/markings shall be in capital letters of equal height, clearly visible and the largest size practical for the package size within the acceptable range. When the marking space permits, stenciled or preprinted markings shall be not less than 3/32 of an inch. The markings shall be located as to allow ease of reading and to ensure that the markings will not be destroyed when the pack or container is opened for inspection or until its contents have been used. If a label is used for the markings then the label shall have a finish suitable for printing and writing on with ink without feathering or spreading, be capable of withstanding normal handling and storage conditions, and remain securely in position. Markings that describe shelf life shall be shown as part of the item identification data on unit packs, intermediate containers and exterior containers (marking is not required for the actual igniter). Markings that describe shelf life shall include the date of manufacture and the re-inspection/test date as appropriate. 2.SPECIAL REQUIREMENTS: Individual packaging must not omit any type of radio frequency signals. Special hazardous material shipment documentation is required. All shipments shall be supported by documentation attesting to the date and the test results obtained from performance packaging testing. The shipper, if not a self-certifier, shall be responsible for assuring that third party sources providing performance testing services are, in fact, registered with the Department of Transportation. The shipper's signed certification that the packaged configuration meets applicable requirements shall be incorporated on the DD Form 250, Material Inspection and Receiving Report, or other related acceptance document if the DD Form 250 is not used. All certificates and reports shall be available for government inspection by authorized government representatives for a period of three years. 3.PRESERVATION, PACKAGING AND DELIVERY: 3.1Department of Defense (DoD) Regulations obligate the utilization of commercial or minimally required packaging protection at the most economical overall cost without compromising established DoD safety standards. If it can be assured the material will not enter the military supply distribution system or be exposed to environments more severe than those normally encountered in the commercial distribution network. These guidelines provide the manufacturer the latitude to determine the most cost effective packaging method to pack and ship the igniters, provided the means of packaging and shipping maintain the integrity of the igniters throughout the designated 15 year life cycle and meet UN/DOT packaging specifications. The contractor shall consistently use Level B Protection, capable of providing protection to meet moderate worldwide shipment, handling and storage conditions. The containers shall be domestically manufactured and of a minimum size to provide a snug fit for the igniters to eliminate the possibility of any free movement during handling and transport. The containers/packaging will be constructed so as not to permit damage to the contents and facilitate subsequent handling. Corrugated containers, will, at a minimum meet the standards of the National Motor Freight Classification (NMFC) item 222. The box will display the manufacturer's certificate that appears on all containers and shall include size and weight limits and strength of fiberboard utilized. When a container that is manufactured to a Government approved drawing or specification has successfully passed all applicable UN recommended performance tests, both the UN performance specification (certification) markings and applicable government approved drawing or container specification marking shall be applied. Although shipping the igniters under a DOT Special Permit (DOT-SP) authorizes deviation from specific requirements of Title 49 CFR, transportation and local requirements such as safety, storage, intra depot movement and the DoD Standardization Program demand more stringent performance oriented packaging specification and has marking requirements. 3.2Inner Pack Marking: Igniters will be packaged (alternate packing materials may be substituted if they achieve a level of safety and protection at least equal to that required by the military specification (MIL-SPEC) and marked as follows: one each igniter, individually (heat) sealed in 4 mil (or greater) antistatic poly tubing, conforming to MIL-PRF-81705D, Type III Commercial equivalent ULINE P/N S-6607 (3 quote mark x 500' roll or as appropriately sized to accept igniter), or anti-static poly bags conforming to MIL-DTL-117, Type II, Class H, Style 2. This heat sealed poly sheath or bag will provide adequate electrostatic discharge protection. 3.3Unit Pack Marking: The unit pack will be marked (stamped or labeled) with the following: P/N 15813-330-01, CAGE code - 3MFD5, Nomenclature quote mark Igniter TTC quote mark, Shelf-life --date of manufacture over inspection/test date - to be established by the manufacturer. ASSEMBLED DATE 10/14, INSP/TEST DATE 10/29, LOT (TBD by manufacturer), ESD caution symbol or mark quote mark ESD Hazard quote mark quote mark Caution quote mark. The contractor shall utilize standard commercial methods for preservation and packaging appropriate for the igniter assembly and the accessory equipment acceptable to commercial carriers. The contractor shall ship the igniters per the proper Department of Transportation (D.O.T.) shipping and hazard classification to include proper UN Performance Oriented Packaging (POP) and appropriate UN POP markings. 3.4Intermediate Pack (inner carton): Packed with an appropriate quantity of igniters (not to exceed 25 each and so packaged that the anti-static poly tubing unit pack acts as cushioning material to maintain igniter separation and prevent friction and impact during transportation). Intermediate packaging will comply with Box, Folding, Style I, seal end, Paragraph 6.1.2.1 of Federal Specification PPP-B-566 or equivalent commercial alternative as determined by the manufacturer. Intermediate packs with less than the established quantity per pack of a specific LOT (end of a production run, etc.) will not be mixed with follow on LOTs. This intermediate pack will be marked with the appropriate actual quantity and prominently marked quote mark LIGT BOX quote mark highlighted with orange paint or ink on the front, back and top of the box. Intermediate packs will be sealed utilizing standard pressure sensitive tape. Inside an intermediate light box empty boxes (filled with fiberboard or similar cushioning) may be utilized as dunnage to support the exterior container and reduce loaded cartons from shifting. The empty boxes will be marked/labeled quote mark EMPTY quote mark and highlighted with orange paint or ink on the front, back and top of the carton. Intermediate Pack Marking (Product Information Label) will be marked (stamped or labeled) with the following: P/N - 15813-330-01, Quantity (determined by the manufacturer), Nomenclature quote mark Igniter TTC quote mark, LOT (TBD by manufacturer/JMC), Weight (TBD by manufacturer), Special Markings of Explosive Label, Class 1.4S (or appropriate HC as assigned by DAC), ESD Caution Label, Shelf-life - date of manufacture over inspection/test date - to be determined by the manufacturer ASSEMBLED DATE 10/14, INPS/TEST DATE 10/29. 3.5Exterior Pack (Exterior or Shipping Container): This container should be packed with an appropriate quantity of intermediate containers (not to exceed 40 pounds gross container weight) and so packaged that the inner carton and the outer packaging form an integral packaging. Once assembled it remains thereafter an integrated single unit; it is filled, stored, shipped and emptied as such. Exterior containers should contain identical quantities of intermediate packs of the same LOTs. If light boxes are packed in exterior packs the container will be appropriately identified with quote mark LIGHT BOX quote mark on the front and the back sides of the container and highlighted with orange paint or ink with a 2 inch wide orange band circumferentially surrounding the top and bottom of the box marked with the appropriate actual quantity. Exterior containers may also include multiple LOTs and will be prominently marked quote mark MIXED LOTS quote mark on the front and back sides of the container and highlighted with yellow paint or ink with a 2 inch wide yellow band circumferentially surrounding the top and bottom of the box marked with the appropriate actual quantity per specified LOTs. When empty boxes (filled with fiberboard or similar cushioning) are utilized as dunnage to prevent loaded boxes from shifting and to square the load, these boxes will be marked quote mark EMPTY quote mark and highlighted with orange paint or ink on front, back and top sides of the carton. All exterior containers will be quote mark UN Certified quote mark as quote mark POP quote mark (performance oriented packaging) and appropriately marked on the lower side of the container that is opposite the product information label. The certification will be prefixed by the UN packing symbol and followed by alpha numeric code as specified in CFR Part 178-3. The proper shipping name will be placed directly below the UN certification. The marking must be stamped, embossed, printed or otherwise permanently marked on a non-removable component of the packaging. Exterior packs will be sealed utilizing standard pressure sensitive tape. If shipping individual exterior containers as quote mark Transport Packages quote mark the container will require a shipping label applied to the individual package adjacent to the product information label (see shipping label below under unitized load marking). Exterior Pack Marking (Product Information Label): The exterior pack will be marked (stamped or labeled) with the following: P/N - 15813-330-01, Cage code - 3MFD5, Nomenclature quote mark Igniter TTC quote mark, Quantity - to be determined by the manufacturer/JMC, WEIGHT - to be determined by the manufacturer, CUBE - to be determined by the manufacturer, Shelf-life - date of manufacture over inspection/test date - to be determined by the manufacturer ASSEMBLED DATE 10/14, INPS/TEST DATE 10/29), Special markings - Explosive label, Class 1.4s, ESD Caution Label, Ground Transport Only, DOT Special Permit - followed by specific exemption number. 3.6Unitized Load (Unit/Pallet Load): The manufacturer has the leeway to determine the most cost effective method to assemble the palletized load for transport. The pallet load will be restrained in such a manner as to eliminate the possibility of the contents of the pallet from movement or shifting during transportation or handling. The materials will be stacked in a method that creates a centered, well balanced and square load. Overhang of containers will be kept to a minimum. A palletized unit load shall never exceed six feet in total height. The load maybe secured by strapping (metal or nylon) or stretch wrap film provided the process maintains the load integrity. If stretch wrap is used it should be secured to all four corners of the pallet. If securing the containers to the pallet by strapping the containers and pallet girth in multiple directions will not be closer than two inches from any edge, then banding will need to encircle the pallet. The corner protectors should be used to protect corrugated fiberboard containers when the tension required to stabilize the load could damage the containers. Palletized unit loads of igniters will have shipping containers facing outward in order to view the product information label. The top layer - right side box (when facing the pallet - on the front and back side of the pallet), will be turned inward to present a blank surface (except UN certification) for application of the shipping label. If the palletized unit load is 10 cubic feet and over, additional identification markings shall be placed on the end of the load adjacent to the shipping label marked side. The required markings shall not be obscured by cleats, strapping or closure tape. When a palletized load is covered with stretch-wrap film, pressure-sensitive labels containing the identification and shipping address markings may be placed on the outmost layer of wrap, on either side of the load. Exterior container identification markings shall be placed on a marking board or panel, securely attached to two adjacent sides of the palletized load, by using a label or by direct stenciling. Palletized loads with smooth, flat surfaces may have identification markings stenciled directly on two surfaces, with markings extending from one container to another. The gross weight for palletized unit loads shall include the weight of the pallet, because palletized loads are often stacked two or three high when shipped or stored, the marking shall be large enough to be read from a distance. The size of the lettering shall be proportionate to the overall size of the unitized load but shall not be less than 0.75 inch in height. The paper labels that are other than pressure sensitive shall be securely affixed with a water resistant label adhesive or a transparent, waterproof, pressure-sensitive tape. Palletized loads of containers of items having different LOTs shall be marked as multipacks. A complete packing list and/or the applicable shipment documentation will be attached in close proximity to the container displaying identification and shipping address markings of each shipment unit. The packing list identifies the contents of a single-piece or multi-piece shipment unit. Water resistant envelopes shall be used for packing lists, material release/receipt documents, MSDSs, etc. and it will be securely affixed or fastened the envelope to the palletized load or container in the most protected location. The use of packing list protectors is recommended. When a DOT-SP (Special Permit) is applicable, the DOT-SP number shall be placed near the shipping name and any other required cautionary markings. The shipper is responsible for the completion of a shipper's declaration for dangerous goods form and MSDS for each and every military shipment. Unitized Load and Transport Container Marking: product information label: P/N - 15813-330-01, Quantity - to be determined by the manufacturer, Nomenclature quote mark Igniter TTC quote mark, Contract number - to be determined after the award, LOT - to be determined by the manufacturer, Shelf-life - date of manufacture over inspection/test date - to be determined ASSEMBLED DATE 10/14, INSP/TEST DATE 10/29, Special Markings - Explosive Label, 1.4S, ESD Caution Label, DOT Special Permit - followed by specific exemption number, Shipping label: Purchase Order or Requisition Number - P/N - 15813-330-01, Ship to Address, Ship from Address, Number of Pieces, Weight (to include pallet), Cube (pallet), Special Markings - Explosive label, Class 1.4S, ESD Caution label, Ground Transportation Only. 3.7As a minimum, all areas susceptible to damage from exposure to the elements shall be preserved and/or packed to prevent damage. The contractor shall be responsible for ensuring the equipment is delivered to Letterkenny Munitions Center, Volez Gate, in good condition, but before this delivery can occur the shipper must utilize Carrier Appointment System (CAS) due to the hazardous shipping schedule restrictions. 4.SECURITY, SAFETY, AND FIRE PREVENTION: The contractor shall comply with LEAD P 385-4, Requirements for Security, Safety, and Fire Prevention for Contractors Performing deliveries to the Letterkenny Munitions Center. 5.FINAL ACCEPTANCE: Final acceptance shall be contingent upon successful completion of all requirements of this purchase description. 6.POINT OF CONTACT: Will be provided at time of award.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/5358e21e2b1d228efc1a753276d75412)
 
Place of Performance
Address: ACC-RSA-LEAD - (SPS) ATTN: CCAM-ALK, 1 Overcash Avenue, Bldg 2 Chambersburg PA
Zip Code: 17201-4152
 
Record
SN03922260-W 20151017/151015234237-5358e21e2b1d228efc1a753276d75412 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.