SOURCES SOUGHT
J -- ALCO Engine Model 251-C Repair
- Notice Date
- 10/26/2015
- Notice Type
- Sources Sought
- NAICS
- 811310
— Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Contracting Office
- Department of the Army, U.S. Army Corps of Engineers, USACE District, Philadelphia, 100 Penn Square East, Wanamaker Bldg (RM 643), Philadelphia, Pennsylvania, 19107-3390, United States
- ZIP Code
- 19107-3390
- Solicitation Number
- ConnectingRods0001
- Archive Date
- 11/13/2015
- Point of Contact
- Bruce E Hayes, Phone: 2156566771
- E-Mail Address
-
Bruce.E.Hayes@usace.army.mil
(Bruce.E.Hayes@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- It is the Government's intention to have a total of eighty-two (82) ALCO model 251-C marine engine connecting rods (ALCO P/N 2170017-1) inspected and certified for use. The Contractor will provide all labor, parts, materials, equipment and services required to inspect and certify the con rods in accordance with all ALCO specifications, including MI-11015C. It is the contractor's responsibility to obtain the publications from FM/ALCO to assure they are using the most current information for the job. The Contractor shall perform the following to each connecting rod assembly, making sure each cap is maintained with the same con rod and in the same orientation: (1) Completely mechanically/chemically clean the con rod assembly. Shot blast as required, (2) Visually inspect for excessive wear, overheating, gouges, nicks, etc (3) Inspect con rod and cap mating surfaces for proper fit and contact, (4) Perform a penetrant dye or magnaflux for cracks, (5) Ensure all oil holes are clear of any obstruction, (6) Perform a dimensional inspection of the crankpin and piston pin bores for diameter, taper and ovality after proper torque as specified by ALCO, (7) Inspect the parallelism between the crankpin and piston pin bore, both horizontally and vertically, (8) Inspect for straightness, bending and twisting, (9) Connecting rod bolts shall be visually inspected and crack tested, also by magnetic particle testing with special attention given to the root thread area. Bolts shall be straight to within 0.010 inches (0.254 mm) total indicator runout, and be free of thread galling, distortion or handling damage. The mating nut shall turn on freely by hand. (10) Torque bolts and verify con rod bolt elongation These requirements are to be completed in conjunction with the information provided by ALCO inspection and rebuilding specifications, requirements, and service manuals. The Government will furnish to the Contractor, the used connecting rods strapped onto pallets. All shipping and transportation fees will be at the Contractor's expense and will be shipped to the contractor C.O.D., or they can be picked up by the Contractor or his representative at Fort Mifflin Distribution Center in Philadelphia, PA. The contractor shall offer, with his quote, a warranty for parts, craftsmanship and workmanship for each connecting rod. This warranty shall be retained on file in case there is a need to undertake some warranty related repairs, at a later date. The warranty shall be set up for the number of operational hours rather than days.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA61/ConnectingRods0001/listing.html)
- Place of Performance
- Address: Fort Mifflin, 6400 Hog Island Rd., Philadelphia, Pennsylvania, 19153-5098, United States
- Zip Code: 19153-5098
- Zip Code: 19153-5098
- Record
- SN03930512-W 20151028/151026234313-2f5612ab34b57c64c5d5516238442b00 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |