Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF NOVEMBER 15, 2015 FBO #5105
SOURCES SOUGHT

36 -- Cooling Water Strainers

Notice Date
11/13/2015
 
Notice Type
Sources Sought
 
NAICS
333999 — All Other Miscellaneous General Purpose Machinery Manufacturing
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Walla Walla, Attn: CENWW-CT, 201 North 3rd Avenue, Walla Walla, Washington, 99362-1876, United States
 
ZIP Code
99362-1876
 
Solicitation Number
W912EF16RSS14
 
Archive Date
2/15/2016
 
Point of Contact
Ruth A. Johnson, Phone: 5095277222
 
E-Mail Address
ruth.a.johnson@usace.army.mil
(ruth.a.johnson@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Contracting Office: US Army Corps of Engineers, Walla Walla District, 201 North Third Avenue, Walla Walla WA 99362. Subject: Sources Sought for the Manufacturing and Delivery of six Cooling Water Strainers for Ice Harbor Lock and Dam located at 2763 Monument Dr., Burbank, WA 99323. Point of Contact: Ruth Johnson, Purchasing Agent, 509-527-7222, ruth.a.johnson@usace.army.mil The NAICS code for this requirement is 333999, All Other Miscellaneous General Purpose Machinery Manufacturing, with a size category of 500 employees. DESCRIPTION OF THE REQUIREMENT: Contractor shall manufacture and deliver NEW Cooling Water Strainers as described below. RAW COOLING WATER DUPLEX STRAINERS OPERATING CONDITIONS: Must be capable of performing during the following normal operating conditions: i. Fluid: Water ii. Flow Rate: 1320 GPM, continuous flow iii. Operating Pressure: 60 PSIG iv. Empty Basket Differential Pressure NTE: 2 PSI v. Operating Temperature: -10° C (14° F) to 90° C (194° F) 2.2. STRAINER HOUSING DESCRIPTION: The duplex raw water strainers shall be Tate Andale Type AL, or equal, with the following salient characteristics: i. Type: Duplex ii. Construction: ASME certified iii. Material: Carbon steel or cast iron with painted exterior and approved equivalent interior corrosion protection iv. Minimum Operational Pressure Rating: 100 PSIG v. Flow Capacity: No less than 1500 GPM vi. Type of Connection: 10 inch, ANSI Class 150 Flange vii. Clogging Indicator: Differential pressure gauge viii. Overall Assembled Dimensions NTE: a. Height: 56 inches b. Width: 38 inches c. Depth: 56 inches ix. Centerline of inlet and outlet flange shall be located at elevation 342.75, or at a minimum, the inlet and outlet flange must be at equal elevations. x. Crossover Valve Assembly: a. Sliding gate valve with hand wheel and LH/RH hand wheel interlocking ability, i.e. chain connection b. Valve position indicator c. Stainless steel or cast iron with ring type valve seal d. Valve Seal: Natural rubber, EPDM rubber, or approved equivalent xi. Weight: NTE 2700 LBS xii. Additional Equipment: a. vent and drain valve b. lifting davit(s) c. pressure equalizing line and two (2) ball valves 2.3. STRAINER FILTER ELEMENT DESCRIPTION: The strainer filter elements shall be the accompanying filter elements of the Tate Andale Type AL strainer, or equal, with the following salient characteristics: i. Type: Removable filter basket with handle ii. Material: Wedgewire of slotted tube style iii. Filtration Rating: 2000 - 4000 microns iv. Maximum Allowable Differential Pressure: 56 PSI v. Basket Open Filtration Area: No less than 314 This is not a solicitation. This information is for planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. Interested parties that respond to this sources sought announcement should submit the following information: (1) Your intent to submit a quote for this project when it is formally advertised (2) Name of firm with address, phone and point of contact. (3) CAGE Code and DUNS number or a copy of your System for Award Management (SAM) information (4) The category of small business, such as 8(a), HUBZONE, or SDVOSB etc. (5) Statement of Capability (SOC) stating your skills, experience, knowledge, and equipment required to perform the specified type of work. This should include documentation of past specialized experience and technical competence in similar work for which your firm was the prime contractor. Interested parties should submit their responses to Ruth Johnson, Purchasing Agent, via email to ruth.a.johnson@usace.army.mil. Your response to this notice must be received by 2:00 PM PST, December 14, 2015.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA68/W912EF16RSS14/listing.html)
 
Place of Performance
Address: Ice Harbor Lock and Dam, 2763 Monument Dr, Burbank, Washington, 99323-8662, United States
Zip Code: 99323-8662
 
Record
SN03945559-W 20151115/151113234306-b49636a0775b366f5dba0cfa3bcbca97 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.