SOLICITATION NOTICE
J -- LMO TRANSFORMER REWIND
- Notice Date
- 11/16/2015
- Notice Type
- Presolicitation
- NAICS
- 334416
— Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing
- Contracting Office
- Department of the Army, U.S. Army Corps of Engineers, USACE District, Walla Walla, Attn: CENWW-CT, 201 North 3rd Avenue, Walla Walla, Washington, 99362-1876, United States
- ZIP Code
- 99362-1876
- Solicitation Number
- W912EF-16-Q-0012
- Point of Contact
- Patricia Thomas, Phone: 5095277212, Julie Morris, Phone: 5095277227
- E-Mail Address
-
patricia.thomas@usace.army.mil, julie.m.morris@usace.army.mil
(patricia.thomas@usace.army.mil, julie.m.morris@usace.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- SYNOPSIS ~ Lower Monumental Dam transformer rewind all-inclusive quote. The solicitation will follow this synopsis within the next 10 days. This is for information only of an upcoming requirement. This specification covers a non-personal services contract for the rewind and testing of a 1000 KVA dry-type transformer. The name "LSP2" will be used throughout this specification to refer to the transformer. A dry-type transformer, identified as "LSP2" by the Government, was found to have insulation resistance readings of less than 2 mega ohms. The Government attempted to resolve the low readings by cleaning and drying, but was not successful. LSP2 was permanently removed from service as a precaution. The transformer shall receive the full set of routine tests as defined in IEEE C57.12.01 and IEEE C57.12.91 as applicable. These requirements constitute a minimum and do not preclude the manufacturer from performing other standard tests. Additional Tests The following tests shall also be performed: a) Insulation power factor b) Insulation resistance and polarization index (index shall be greater than 1.0) c) Winding resistance d) Turns ratio Test Reports The Contractor shall submit test reports for all required tests. The test reports shall include actual test values and any applicable acceptance criteria. Shipping and Delivery The Contractor shall make all arrangements for shipping at no cost to the Government. Include shipping costs within the total price. The Government will provide crane support to load and unload the transformer at Lower Monumental Lock and Dam. The complete transformer and all accessories shall be delivered FOB Destination to Lower Monumental Lock and Dam. The Contractor shall be responsible for packing and shipping the components in a manner that ensures the undamaged and complete arrival to Lower Monumental Lock and Dam. Deliveries will only be accepted Monday-Thursday 6:30AM-4PM, excluding Federal Holidays
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA68/W912EF-16-Q-0012/listing.html)
- Place of Performance
- Address: LOWER MONUMENTAL DAM, 5520 DEVILS CANYON RD, KAHLOTUS, Washington, 99335, United States
- Zip Code: 99335
- Zip Code: 99335
- Record
- SN03946588-W 20151118/151116234310-43217ffa5e609a1d4c997bd0883649ad (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |