H -- Inspection & Calibration for two (2) Tescom Fire Valve Test Stands model

Notice Date
11/18/2015
 
Notice Type
Presolicitation
 
NAICS
811219 — Other Electronic and Precision Equipment Repair and Maintenance
 
Contracting Office
Department of the Army, Army Contracting Command, ACC - Warren (ACC-WRN)(RRAD), 100 MAIN DRIVE BUILDING 431, TEXARKANA, Texas, 75507-5000, United States
 
ZIP Code
75507-5000
 
Solicitation Number
W911RQ16T0006
 
Point of Contact
SANDRA JEANLOUIS, Phone: 9033344283
 
E-Mail Address
sandra.jeanlouis.mil@mail.mil
(sandra.jeanlouis.mil@mail.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Scope of Work: 1) The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items to perform yearly inspection & calibration of the two (2) each Tescom Valve Test Stands model NA-134. All Tests shall be in OEM (Kidde) standards are fully operational and capable of testing (750psi) and newer(900psi), and Calibrate equipment for all functions the OEM originally designed the equipment to perform. 2) The contractor shall provide qualified and experienced personnel in the inspection, testing and calibrate of the two (2) each Tescom Valve Test Stands model NA-134; at Red River Army Depot, Texarkana, Texas. 3) Provide all Labor and Materials necessary to inspect two (2) each Tescom Fire Valve test stands model # NA-134 to insure test stands are fully operational and capable of testing (750psi) and newer (900psi). Calibrate equipment for all functions the OEM originally designed the equipment to perform. 4) The unit will be inspected & calibrated to insure that all specifications and tolerances will be In accordance with OEM (Kidde) standards Document # 12308790 which stated: Continuity test;.87 +/-.24Ohms, 1500psig (1800psig for newer valve) proof test: 5 minutes and observe pressure loss, check tank full switch (newer valves), electrical fire test (fire less than 10 milliseconds, pull test, initial leakage test (monitor pressure release for 1 minute). Period of Performance: One Base Year of 12 months and three (3) 12-months option years, for a total of 4 years. Deliverables: Contractor upon completion of inspection and calibration of the Tescom NA-134 equipment will provide a letter of calibration valid for one year (12 months) from the date of inspection and calibration.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/319753018a9713cc40aa616bdd380648)
 
Place of Performance
Address: RED RIVE ARMY DEPOT, TEXARKANA, Texas, 75507, United States
Zip Code: 75507
 
Record
SN03948884-W 20151120/151118234238-319753018a9713cc40aa616bdd380648 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.