Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF DECEMBER 18, 2015 FBO #5138
MODIFICATION

Y -- DB Precision Guided Missile Maintenance Facility - Sources Sought, Revised

Notice Date
12/16/2015
 
Notice Type
Modification/Amendment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Sacramento, 1325 J. Street, Sacramento, California, 95814, United States
 
ZIP Code
95814
 
Solicitation Number
W91238-16-S-3110
 
Point of Contact
Daniel E. Czech, Phone: 9165577012
 
E-Mail Address
Daniel.E.Czech@usace.army.mil
(Daniel.E.Czech@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Sources Sought, Revised W91238-16-S-3110 This is a SOURCES SOUGHT NOTICE for Market Research ONLY to determine the availability of small business firms for a potential small business category type set-aside. NO AWARD will be made from this Sources Sought. NO SOLICITATION, SPECIFICATIONS, OR DRAWINGS ARE AVAILABLE AT THIS TIME; therefore, do NOT request a copy of a solicitation. Potential offerors having the skill, capabilities and bonding necessary to perform the described project are invited to provide feedback via email to DANIEL CZECH at Daniel.E.Czech@usace.army.mil. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition. Particularly, the purpose of this NOTICE is to gain knowledge of potential small business sources to include small business in the following categories: Small Business, Certified 8a, Certified HUB Zone, and Service-Disabled Veteran-Owned Small Business (SDVOSB), for design-build construction of a Precision Guided Missile Maintenance Facility at Hill AFB, UT. The capabilities will be evaluated solely for the purpose of determining to Set-Aside for the Small Business Community or to conduct as an Other Than Small Business Procurement. Other than small businesses may respond to this NOTICE to indicate their interest in the project; however, preference will be given to the SB categories listed above. The government must ensure there is adequate competition among the potential pool of available contractors. This project is planned for advertising during August 2016. In accordance with FAR 36.204(g), the estimated value of the resulting contract is expected to be between $5M and $10M. It is estimated to have a duration of less than 550 days. The resulting contract type is expected to be a Firm-Fixed Price. The NAICS Code is 236220, the size standard is $36.5 million, and the Federal Supply Code is Y1BF, Construction of Missile System Facilities. Under Federal Acquisition Regulation (FAR) guidelines 52.219-14, any 8(a) concern will perform at least 15% of the cost of the contract, not including the cost of materials, with its own employees for specialty general construction. Under FAR 52.236-1, any other-than-small business concern shall perform on the site, and with its own organization, work equivalent to at least 20 percent of the total amount of work to be performed under the contract. PROJECT DESCRIPTION Construct a single story, multi-bay Precision Guided Missile (PGM) maintenance facility composed of reinforced concrete footings, foundation, and elevated floor slab to accommodate a reinforced concrete loading dock at the work bays. Facility will be designed as a permanent construction in accordance with UFC 1-200-01. Provide 12 inch thick reinforced interior concrete dividing walls between work bays with minimum strength of 3500 psi and a 12 inch thick reinforced concrete exterior walls and insulated standing seam metal roof. Include an administrative support core with standard metal stud partition walls to form private offices, men's and women's restrooms, tool room, general storage, mechanical room, electrical room, communications room, vault, and break room. Each work bay to be equipped with 400 Hz/3 phase power, explosion proof lighting, high pressure air, and an 18 foot wide by 20 foot high overhead door. Provide overall catenary lightning protection, surge protection, intrusion detection, fire detection and suppression, grounding, and exterior lighting as required. Project includes all supporting utilities, site improvements, communication infrastructure, and pavements; including a reinforced concrete approach apron in front of a raised loading dock. Loading dock to be of reinforced concrete construction and to be equipped with one dock leveler mechanism in from of each work bay door. The project will comply with DOD Antiterrorism protection requirements per UFC 4-010-01. Sustainable principles, to include Life Cycle cost effective practices, will be integrated into the design, development, and construction of this project in accordance with UFC 1-200-02. CAPABILITY STATEMENT The following requests are designed to apprise the US Army Corps of Engineers, Sacramento District, of any prospective construction contractors' project execution capabilities. Please provide your response to the following. The submission is limited to 10 pages. 1) Offeror's name, DUNS#, address, point of contact, phone number, and e-mail address. 2) Offeror's interest in bidding on the solicitation when it is issued. 3) Offeror's capability to perform contracts of this magnitude and complexity and comparable work performed within the past 5 years - Describe your self-performed effort, brief description of the project, customer name, timeliness of performance, customer satisfaction, and dollar value of the project) - provide at least 3 examples. 4) Offeror's socioeconomic type and business size (Small Business, HUBZone, Service Disabled Veteran Owned and/or Small Business, 8(a), WOSB, etc.). 5) Offeror's Joint Venture information if applicable - existing and potential. 6) Offeror's Bonding Capability in the form of a letter from Surety. The Capabilities Statement for this sources sought is not expected to be a Request for Proposal or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach, but rather short statements regarding the company's ability to demonstrate existing-or-developed expertise and experience in relation to the areas specified herein. Any commercial brochures or currently existing marketing material may also be submitted with the Capabilities statement. Please ensure that all information is submitted as one (1) document. Submission of Capabilities statement is not a prerequisite to any potential future offerings, but participation will assist the Corps of Engineers in tailoring requirements to be consistent with industry capabilities. This synopsis is for information and planning purposes only and is neither to be construed as a commitment by the Government nor will the Government pay for information solicited. Respondents will not be notified of the results of the evaluation. After completing its analysis, the Government will determine whether to limit competition among 8(a), Service Disabled Veteran, HubZone, etc., or all Small Business firms or proceed with full and open competition as Other Than Small Business. Offers that do not meet all requirements or submit within the allotted time may not be considered. Please notify this office in writing by email by 2:30 PM Pacific Time on Jan 15, 2016. Submit response and information through email to: Daniel.E.Czech@usace.army.milPlease include the Sources Sought No. W91238-16-S-3110 in the subject line.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA05/W91238-16-S-3110/listing.html)
 
Place of Performance
Address: Hill AFB, Utah, United States
 
Record
SN03971486-W 20151218/151216234809-15070624b9129ff078e9ca9c6d1d47b9 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.