Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF DECEMBER 31, 2015 FBO #5151
DOCUMENT

Y -- AITC - Construction Diesel Fuel Control System - Attachment

Notice Date
12/29/2015
 
Notice Type
Attachment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of Veterans Affairs;Central Texas Veterans HCS;1901 S. 1st Street;Temple TX 76504
 
ZIP Code
76504
 
Solicitation Number
VA25716B0356
 
Archive Date
2/27/2016
 
Point of Contact
Patricia L Chandler
 
E-Mail Address
899-6016<br
 
Small Business Set-Aside
N/A
 
Description
VA Austin Information Technology Center (AITC) anticipates awarding a Firm Fixed Price Construction Contract for a turn-key project to engineer, provide and construct a diesel fuel control system for an emergency generator system. Salient characteristics of the various pieces of integrated equipment will be provided in the solicitation. The project number is 200SN3089 and is located at the AITC, 1615 Woodward Street, Austin, TX 78772. The contractor shall be responsible for, but not limited to, furnishing all labor, tools, materials, equipment and supervision. General Scope of Work: Provide all labor, materials, supplies, tools and equipment, supervision and construction services necessary to engineer, provide and construct a diesel fuel control system for an emergency generator system at the AITC, Austin TX, Project 200SN3089. Contract will include, but not limited to, the following: "Provide pumps, valves, and all ancillary equipment needed to deliver fuel to one (1) 750KW, two (2) 900 KW, one (1) 1000 KW and four (4) 2250 KW generators. This will include integration with the two (2) existing 15,000 gallon above-ground storage tanks, one (1) future tank and Veeder Root tank monitoring system. "Control system shall be capable of automatically switching fuel supply from one tank to another, transferring fuel from one fuel tank to another. "Each fuel supply/return line shall have its own manual bypass valve. "Design shall include three (3) skid mounted supply pumps and associated valves and shall be mounted on a concrete pad sized so that only one (1) pump is required to operate while the other two (2) pumps serve as redundant pumps. "Design includes provision for solenoid valves on each supply and return line. "Provide and install an Automatic Transfer Switch to operate from 2 sources (old generator power system and the new generator power system). GE model # Zenith ZTX Series or approved equal. Refer to attached drawings for power sources. "Provide and install a 277/480 volt 3 phase 4 wire 60HZ. Electric panel board. Square D Model #NF or approved equal. "Provide and install a 480 primary voltage to 120/208 secondary voltage transformer. Square D Model #45T3HNV or approved equal. "Provide and install a 277/480 volt 3 phase 4 wire 60HZ. Electric panel board. Square D Model #QO or approved equal. Contractor shall adhere to special security requirements (e.g., stringent background checks, security training, limited access, daily inspections) which will probably result in extra costs and time in accessing the job site. Contractor shall ensure that all personnel under his employment are familiar with and obey all applicable regulations of AITC. Normal business hours are between 7:00 AM and 4:00 PM, Monday through Friday. Work that might disrupt building staff such as loud disruptive work or work causing strong odors, etc. shall be done after normal business hours. The period of performance is 120 calendar days after issuance of Notice to Proceed (NTP). The method of procurement shall be an Invitation for Bid (IFB) in accordance with Parts 14 and 36 of the FAR, with an estimated solicitation release date of on or about January 7, 2016 and a bid due date on or about February 11, 2016. The VA reserves the right to use only Federal Business Opportunities/FedBizOpps (FBO) website - www.fbo.gov via the internet, to provide notification of any amendments to this requirement and to post the subsequent IFB solicitation. It is the contractor's responsibility to view the FBO website daily for any amendments to this requirement and to obtain the IFB, Specifications, and Drawings. This procurement is a competitive offer and the solicitation will be advertised as 100% set-aside for Service Disabled Veterans Owned Small Businesses (SDVOSB), under Public Law 109-461 (38 USC 8127), offers received from other than SDVOSB concerns will not be considered. The NAICS Code is 236220, with a business size standard of $36.5 Million. Probable Cost Range: Between $250,000 and $500,000
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VACTHCS674/VACTHCS674/VA25716B0356/listing.html)
 
Document(s)
Attachment
 
File Name: VA257-16-B-0356 VA257-16-B-0356_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2485780&FileName=VA257-16-B-0356-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2485780&FileName=VA257-16-B-0356-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN03979223-W 20151231/151229233918-2e9ab491d21d8752beb2b45a09d80e36 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.