SOURCES SOUGHT
J -- The repairs and replacement parts for the Leica TS15 I 1" R1000 Total Station - W912ES-16-SS-0009 Sources Sought
- Notice Date
- 1/15/2016
- Notice Type
- Sources Sought
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- Department of the Army, U.S. Army Corps of Engineers, USACE District, St. Paul, Attn: CEMVP-CT, 180 East Fifth Street, St. Paul, Minnesota, 55101-1678, United States
- ZIP Code
- 55101-1678
- Solicitation Number
- W912ES-16-SS-0009
- Archive Date
- 2/5/2016
- Point of Contact
- Terry Zenker, Phone: 6512905407, Shamron J. Richardson, Phone: 651-290-5415
- E-Mail Address
-
terry.g.zenker@usace.army.mil, shamron.j.richardson@usace.army.mil
(terry.g.zenker@usace.army.mil, shamron.j.richardson@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- The repairs and replacement parts for the Leica TS15 I 1' R1000 Total Station The U.S. Army Corps of Engineers (USACE), St. Paul, Minnesota District is seeking interested sources for providing the repairs and replacement parts for a Leica TS15 I 1" R1000 Total Station. The repairs will be completed at contractors' facility and repaired equipment will be delivered to the Fountain City WI Service base, Fountain City WI. Due to the need to recalibrate to manufacturer's tolerances, the Corps' intent is to award a sole source firm-fixed-price requirements contract to Leica Geosystems, Inc. who manufactured the Leica TS15 I 1" R1000 Total Station. The contractor will replace, repair and recalibrate the following: All supplied parts shall be compatible with the Leica TS15 I 1" R1000 Total Station. General - Housing / Cover / Transport Case damaged Optics / Telescope - Main Objective damaged Optics / Telescope - Optics misaligned Optics / Telescope - Tube run off out of tolerance Display / Keyboard - Display broken (glass cracked) Display / Keyboard - Display/Touch non-functioning EDM - Optics / Diode misaligned Tilting axis / V-Circle - Out of tolerance Standing axis / Hz-Circle - True running of standing axis out of tolerance Recalibrate to manufacturer specifications and tolerances. A diagnostic performed indicated the need to repair or replace the following: 1. Cover Sealing - 2 ea 2. Side Cover Sealing - 2 ea 3. ALHIDADE-Membrane - 1 ea 4. Focusing Knob - 1 ea 5. Keyboard - 2 ea 6. Horizontal tensioned worm wheels - 1 ea 7. Standing axis with horizontal circle for TS15 - 1 ea 8. Support assembly - Pale Green color - 1 ea 9. Tilting axis with vertical circle - 1 ea 10. TS15 Lens cap - 1ea 11. O-Ring - 1 ea 12. Leica preassembled frontframe - 1 ea 13. KDU assembled "Leica" GGF - 1 ea 14. Eagle Backframe - 1 ea 15. SET encoder 3,3V with magnet brake - 1 ea 16. Instrument Label TS15 - 2 ea 17. RH15 radio handle - 1 ea 18. Calibrate Leica TS15 I 1" R1000 Total Station to manufacture's specification The quote submitted shall include all shipping and related costs. The Leica Total Station is currently located at 1500 Boggs Road, Duluth, GA 30096. The Contractor is responsible for arranging shipping from the current location to the Contractor's repair facility and then shipping the repaired Leica TS15 I 1" R1000 Total Station back to the Army Corps of Engineers at the address listed below. SHIPPING: US Army Corps of Engineers, 431 North Shore Dr, Fountain City, WI 54629 No additional repairs are authorized under this contract unless approved in writing by the Contracting Officer.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA37/W912ES-16-SS-0009/listing.html)
- Record
- SN03993903-W 20160117/160115234210-546442ed2c4eb0815e8f44e7ff30480c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |