Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF FEBRUARY 13, 2016 FBO #5195
DOCUMENT

65 -- (c) Embolization Coil & Balloon Catheter BPA - Attachment

Notice Date
2/11/2016
 
Notice Type
Attachment
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office;NCO 19;4100 E. Mississippi Avenue, Suite 900;Glendale CO 80246
 
ZIP Code
80246
 
Solicitation Number
VA25916Q0195
 
Response Due
2/17/2016
 
Archive Date
3/3/2016
 
Point of Contact
Brooke Barker
 
Small Business Set-Aside
N/A
 
Description
(i)This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. (ii)The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-83C/84. (iii)The solicitation number is: VA259-16-Q-0195, and it is issued as a request for quotation (RFQ). (iv)The VA is anticipating awarding up to a 5 year open market BPA in accordance with FAR 13.303 in result of this synopsis/solicitation. (v)This solicitation is not set-aside for Small Business. NAICS: 339113. (vi)Contract Line Items: Brand Name or Equal IAW FAR 52.211-6. SPECIFICATIONS: TORNADO Embolization Coil: PART NUMBERRECOMMENDED CATHETER ID AND END HOLE DIAMETER inchEXTENDED EMBOLUS LENGTH cmCOILED EMBOLUS TAPERING DIAMETER mm MWCE-18S-8/4-TORNADO.0189.58 - 4 MWCE-18S-10/4-TORNADO.01814.210 - 4 MWCE-18S-7/3-TORNADO.01897 - 3 MWCE-18S-6/2-TORNADO.01876 - 2 MWCE-18S-3/2-TORNADO.01823 - 2 MWCE-18S-5/2-TORNADO.01855 - 2 MWCE-18S-4/2-TORNADO.01844 - 2 MWCE-35-8/5-TORNADO.0358.28 - 5 MWCE-35-10/5-TORNADO.03512.510 - 5 MWCE-35-6/3-TORNADO.0355.86 - 3 MWCE-35-7/3-TORNADO.03587 - 3 MREYE Embolization Coil: PART NUMBERRECOMMENDED CATHETER ID AND END HOLE DIAMETER inchEXTENDED EMBOLUS LENGTH cmCOILED EMBOLUS TAPERING DIAMETER mmAPPROX. NO. OF LOOPS IMWCE-35-10-5 IMWCE-35-5-3.035535.3 IMWCE-35-5-8.035582.0 IMWCE-35-14-12.03514123.7 NESTER Embolization Coil: PART NUMBERRECOMMENDED CATHETER ID AND END HOLE DIAMETER inchEXTENDED EMBOLUS LENGTH cmCOILED EMBOLUS TAPERING DIAMETER mmAPPROX. NO. OF LOOPS MWCE-18-5-5-NESTER.018553.2 MWCE-18-5-2-NESTER.018528.0 MWCE-18-7-2-NESTER.0187211.1 MWCE-18-7-10-NESTER.0187102.2 MWCE-35-7-3-NESTER.035737.4 MWCE-35-14-10-NESTER.03514104.5 MWCE-35-14-4-NESTER.03514411.1 MWCE-35-14-6-NESTER.0351467.4 MWCE-35-14-8-NESTER.0351485.6 MWCE-35-7-10-NESTER.0357102.2 ADVANCE 18/35 LP Low-Profile PTA Balloon Dilatation Catheter: PART NUMBERACCEPTS WIRE GUIDE DIAMETER inchINFLATED BALLOON DIAMETER inchBALLOON LENGTH cmCOMPATIBLE SHEATH FrRATED BURST PRESSURE atm PTA4-18-150-3-4.018344.014 PTA4-18-150-3-6.018364.014 PTA4-18-150-4-4.018444.014 PTA4-18-150-4-8.018484.014 PTA4-18-80-4-4.018444.014 PTA4-18-80-4-8.018484.014 PTA5-35-80-4-8.0.035485.015 PTA5-35-80-5-12.0.0355125.015 PTA5-35-80-6-10.0.0356105.015 PTA5-35-80-6-14.0.0356176.015 PTA5-35-80-7-10.0.0357106.012 PTA5-35-80-7-17.0.0357176.012 PTA5-35-80-8-10.0.0358106.011 PTA5-35-135-5-12.0.0355125.015 PTA5-35-135-6-14.0.0356145.015 PTA5-35-135-7-4.0.035745.012 PTA5-35-135-7-10.0.0357106.012 PTA5-35-135-7-17.0.0357176.012 PTA5-35-135-12-4.0.0351247.08 Low profile, flexible tip, rapid inflation and fast balloon deflation. (vii)Description of requirements for the items to be acquired: The George E. Wahlen VA Salt Lake City Health Care System is anticipating a single award 5 year BPA for the above items. (1)Description: The supplier shall furnish the required supplies (listed above) if and when requested by the contracting officer (or the authorized representative of the contracting officer) for the duration of the BPA, which is 5 years from the date of award. (2)Extent: The Government is obligated only to the extent of authorized purchases actually made under the BPA. (3)Purchase limitation: The dollar limitation for each individual order: $150,000.00. All orders $3,500.00 and under will be placed via Government Purchase Card (GPC). All orders over $3,500.00 will be issued via a Purchase Order from a warranted Contracting Officer from Network Contract Office 19 (NCO 19). (4)Individuals authorized to purchase under the BPA: The logistics team at the Salt Lake City VA Medical Center is authorized to place orders up to $3,500.00. All orders over $3,500.00 will be issued via a Purchase Order from a warranted Contracting Officer from Network Contract Office 19 (NCO 19). (5)Delivery tickets: All shipments under the agreement shall be accompanied by delivery tickets or sales slips that shall contain the following minimum information: a.Name of supplier. b.BPA number. c.Date of purchase. d.Purchase number. e.Itemized list of supplies furnished. f.Quantity, unit price, and extension of each item, less applicable discounts. g.Date of delivery or shipment. (6)Invoices: When billing procedures provide for an individual invoice for each delivery, these invoices shall be accumulated, provided that - a.A consolidated payment will be made for each specified period; and b.The period of any discounts will commence on the final date of the billing period or on the date of receipt of invoices for all deliveries accepted during the billing period, whichever is later. (viii)Date and place of delivery (FOB Destination): Delivery shall be within 30 days ARO. Salt Lake City VAMC 500 Foothill Drive Salt Lake City, UT 84148-0001 (ix)The provision at 52.212-1, Instructions to Offerors - Commercial, applies to this acquisition. (x)The provision at 52.212-2, Evaluation - Commercial Items, does not apply to this acquisition. Award will be made based on Lowest Price Technically Acceptable (LPTA). (xi)Offerors are advised to include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications - Commercial Items, with the offer. (xii)The clause at 52.212-4, Contract Terms and Conditions - Commercial Items, applies to this acquisition. (xiii)The clause at 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items, applies to this acquisition. (xiv)Any additional contract requirements or terms and conditions: 52.211-6, 52.232-40, 52.247-34, 852.203-70, 852.236-90, 852.232-72. All Contractors MUST be registered in SAM.gov to do business with the federal government and annually ensure the information is current at https://www.sam.gov/ (xv)The Defense Priorities and Allocations System (DPAS) does not apply. (xvi)Date and Time offers are due: 2-17-2016 @1700 Mountain Time. (xvii)Use attached (below) form for pricing. (xviii)Name and telephone number of the individual to contact for information regarding the solicitation: Brooke Barker Contract Specialist Department of Veterans Affairs, NCO-19 307-433-3768 Brooke.barker@va.gov PRICING: LINE ITEMPART NUMBEREST. YEARLY USAGEUNIT PRICE TORNADO Embolization Coil: 0001MWCE-18S-8/4-TORNADO G0921510 0002MWCE-18S-10/4-TORNADO G0921710 0003MWCE-18S-7/3-TORNADO G0921820 0004MWCE-18S-6/2-TORNADO G082596 0005MWCE-18S-3/2-TORNADO G0826117 0006MWCE-18S-5/2-TORNADO G0835611 0007MWCE-18S-4/2-TORNADO G0835711 0008MWCE-35-8/5-TORNADO G1041212 0009MWCE-35-10/5-TORNADO G104139 0010MWCE-35-6/3-TORNADO G1041617 0011MWCE-35-7/3-TORNADO G1041715 LINE ITEMPART NUMBEREST. YEARLY USAGEUNIT PRICE MREYE Embolization Coil: 0012IMWCE-35-10-5 G1995613 0013IMWCE-35-5-3 G4241915 0014IMWCE-35-5-8 G424238 0015IMWCE-35-14-12 G4789013 LINE ITEMPART NUMBEREST. YEARLY USAGEUNIT PRICE NESTER Embolization Coil: 0016MWCE-18-5-5-NESTER G2352017 0017MWCE-18-5-2-NESTER G5273317 0018MWCE-18-7-2-NESTER G5273517 0019MWCE-18-7-10-NESTER G5274116 0020MWCE-35-7-3-NESTERG2352315 0021MWCE-35-14-10-NESTER G269916 0022MWCE-35-14-4-NESTER G269934 0023MWCE-35-14-6-NESTER G269944 0024MWCE-35-14-8-NESTER G2699512 0025MWCE-35-7-10-NESTER G527455 LINE ITEMPART NUMBEREST. YEARLY USAGEUNIT PRICE ADVANCE Low-Profile PTA Balloon Dilatation Catheter: 0026PTA4-18-150-3-4 G343194 0027PTA4-18-150-3-6 G343204 0028PTA4-18-150-4-4 G343244 0029PTA4-18-150-4-8 G343264 0030PTA4-18-80-4-4 G502274 0031PTA4-18-80-4-8 G502314 0032PTA5-35-80-4-8.0 G523334 0033PTA5-35-80-5-12.0 G523424 0034PTA5-35-80-6-10.0 G523484 0035PTA5-35-80-6-14.0 G523504 0036PTA5-35-80-7-10.0 G523554 0037PTA5-35-80-7-17.0 G343664 0038PTA5-35-80-8-10.0 G523624 0039PTA5-35-135-5-12.0 G522624 0040PTA5-35-135-6-14.0 G522704 0041PTA5-35-135-7-4.0 G522726 0042PTA5-35-135-7-10.0 G522754 0043PTA5-35-135-7-17.0 G355394 0044PTA5-35-135-12-4.0 G522996 Quantities are an estimated yearly usage and are not guaranteed. Contractor is only due money for supplies ordered and received throughout the BPA. The VA is requesting pricing for these items for a five year period. JUSTIFICATION FOR SINGLE SOURCE AWARDS IAW FAR 13.106-1 (OVER MICRO-PURCHASE THRESHOLD($3K) BUT NOT EXCEEDING THE SAT ($150K)) IAW FAR13.104, COs must promote competition to the maximum extent practicable to obtain supplies and services from the source whose offer is the most advantageous to the Government, considering the administrative cost of the purchase. When competition is not practicable, IAW FAR13.106-1(b), COs solicit from a single source for purchases not exceeding the simplified acquisition threshold. COs may solicit from one source if the CO determines that the circumstances of the contract action deem only one source reasonably available (e.g., urgency, exclusive licensing agreements, brand-name or industrial mobilization). IAW FAR13.106-3(b)(3),COs are required to include additional statements explaining the absence of competition (see 13.106-1 for brand name purchases) if only one source is solicited and the acquisition does not exceed the simplified acquisition threshold (does not apply to an acquisition of utility services available from only one source) or supporting the award decision if other than price-related factors were considered in selecting the supplier. This template when completed can be used to document single source awards IAW FAR13.106-3(b)(3). Note: Statements such as "only known source" or "only source which can meet the required delivery date" are inadequate to support a sole source purchase. 1. PURCHASE REQUEST OR REQUISITION NUMBER: n/a1A. PROJECT/TASK NUMBER: n/a1B. ESTIMATED AMOUNT: 2. BRIEF DESCRIPTION OF SUPPLIES OR SERVICES REQUIRED AND THE INTENDED USE: The Salt Lake VAMC has a requirement for Tornado, MReye and Nester Embolization Coils and Advance Balloon Catheters. The embolization coils are used in multiple procedures relating to removing malformations and lesions. The Tornado embolization coil is used for embolization of selective vessel supply to arteriovenous malformations and other vascular lesions. Tornado embolization coils are ideally suited for tapering vessel situations. The MReye embolization coil is used in peripheral arterial and venous vessel embolization procedures. The Nester embolization coil is used for arterial and venous vessel embolization. The balloon catheters are used for percutaneous transluminal angioplasty of lesions in peripheral arteries, including the iliac, renal, popliteal, infrapopliteal, femoral and iliofemoral arteries, as well as obstructive lesions of native or synthetic arteriovenous dialysis fistulae. 3. UNIQUE CHARACTERISTICS THAT LIMIT AVAILABILITY TO ONLY ONE SOURCE, WITH THE REASON NO OTHER SUPPLIES OR SERVICES CAN BE USED: The physicians have received additional training on these specific embolization coils and balloon catheters, and have been using them exclusively. Using Cook Medical's embolization coils and balloon catheters removes the need for additional training. The physicians have used other products in the past, but have experienced increased patient safety and reduced recovery time and hospital stay. 4. REASON THAT SUGGESTED SOURCE IS THE ONLY SOURCE, WHICH CAN PROVIDE THE SUPPLIES OR SERVICES: Cook Medical is the sole manufacturer of the Tornado, MReye and Nester embolization coils as well as the Advance balloon catheter. The Salt Lake VAMC already has the equipment to place these items in patients. 5. DESCRIPTION OF MARKET RESEARCH CONDUCTED AND RESULTS OR STATEMENT WHY IT WAS NOT CONDUCTED: A review of national contracts and prime vendors showed that this requirement is not available from a VA NAC contract source. A review of current WSNC BPAs as well as VISN, regional and local IDIQs did not find any vendors able to fulfill this requirement. Other sources including, AbilityOne, Federal Prison Industries (FPI) and excess stock from other agencies returned negative results. An internet search showed that these items are available via open market. 6. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106-1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief. End of document.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/VA25916Q0195/listing.html)
 
Document(s)
Attachment
 
File Name: VA259-16-Q-0195 VA259-16-Q-0195.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2554678&FileName=VA259-16-Q-0195-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2554678&FileName=VA259-16-Q-0195-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;Salt Lake VA Medical Center;500 Foothill Drive;Salt Lake City, UT 84148
Zip Code: 84148
 
Record
SN04018736-W 20160213/160211235214-613006f8a13cfe94ee0dea8e1f930f23 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers