- Description
- Vendor Questions Concerns for: 619-16-1-5243-0006 / VA247-16-R-0356 / ELECTRICAL VOLTAGE TESTING 1) One-line diagrams would be very helpful. In addition, there is a mention of a load study and infrared panels for the CAVHCS in Montgomery. These requirements are not listed for the Tuskegee location but are they required? Load study for Tuskegee no, infrared yes. 2) In addition, what equipment is a load study required for and for what length of time? How many load studies would need to occur simultaneously? The load study is required to determine if all equipment on the emergency circuits exceed the 30% rating for the generator to eliminate annual load bank testing, however a 4 hour load bank of all generators is required to satisfy Joint Commission requirements. 3) With respect to the infrared panels does this mean they want the panelboards to be infrared scanned? Yes 4) What about dry type transformers and other equipment that is typically infrared scanned? All panels and transformers require infrared scanning to determine hotspots 5) Would infrared scans be limited to only the Montgomery location? No. 6) For the pad-mounted switches and transformers, do SF6 gas and oil samples need to be tested and analyzed? Yes 7). Generators. a. What type of test are to be performed on the ten (10) generators at the Tuskegee facility? Minimum of 4 hour load test (dynamic or static) that is at least 30% of the nameplate rating of the generator per Joint Commission EC.02.05.07 EP8 b. Are the generators to be "Load Bank Tested"? Yes 8) High Voltage Switchgear a. Besides the normal testing, "Load test high voltage equipment" is asked for. Can this statement be clarified? The testing should follow the guidance laid out by the National Electrical Testing Association (NETA) as stated in VHA Directive 1028. 9) Will equal certifications to NETA be acceptable such as Professional Engineer and degreed engineer with more than 30 years experience? Section 2 sub paragraph (a) of the SOW states that Contractors shall be certified IAW NETA, if the professional or degreed engineer is NETA certified, then yes, otherwise no. 10) Is VHA Directive 2014-1028 a part of this contract? This directive specifies load bank testing of generators (not listed in the specifications) Section 1 sub para (b)- " Supplies and services: Professional testing and maintenance of electrical systems and equipment. Furnish all labor, equipment and supplies necessary to provide electrical analysis to include specialized testing, inspecting, cleaning, adjusting and appraising of electrical distribution system and apparatus to assure their reliable operation. Testing shall be performed in compliance with manufacturer's recommendations and applicable NEMA, NEC, ANSI, ASTM, ASA, and VA standards." 11) VHA Directive 2014-1028 states that circuit breakers 250 amps and above must be tested. Breakers below 250 amps must be exercised. See response to question 10
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/MoVAMC/VACAHCS/VA24716R0356/listing.html)
- Document(s)
- Attachment
- File Name: VA247-16-R-0356 VA247-16-R-0356_2.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2583246&FileName=VA247-16-R-0356-001.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2583246&FileName=VA247-16-R-0356-001.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA247-16-R-0356 VA247-16-R-0356_2.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2583246&FileName=VA247-16-R-0356-001.docx)
- Place of Performance
- Address: Department of Veterans Affairs;Central Alabama Veterans Health Care;2400 Hospital Road;Tuskegee, AL 36083
- Zip Code: 36084
- Zip Code: 36084
- Record
- SN04032400-W 20160228/160226234242-92bce07d08279518f526ece689ef9191 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |