DOCUMENT
J -- Install Phenolic Foam Insulation on secondary supply and Return Lines - Attachment
- Notice Date
- 3/8/2016
- Notice Type
- Attachment
- NAICS
- 811310
— Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Contracting Office
- Department of Veterans Affairs;Purchasing and Contracting NCO 16;Michael E. DeBakey VA Medical Center;2002 Holcombe BLVD;Houston TX 77030 4298
- Solicitation Number
- VA25616N0387
- Response Due
- 3/11/2016
- Archive Date
- 3/25/2016
- Point of Contact
- Jarvis D Washington
- E-Mail Address
-
1-7418<br
- Small Business Set-Aside
- N/A
- Description
- DRAFT STATEMENT OF WORK Install Phenolic Foam Insulation I.GENERAL REQUIREMENT Install Phenolic Foam Insulation on supply and Return Lines. Additionally, Install Phenolic Foam Insulation surrounds on primary pumps. The contractor shall provide all labor, materials, supervision transportation, personnel and all other resources required to re-insulate chilled water pump supply and return piping with Phenolic type insulation and wrap in PVC.020 PVC jacketing. Also contractor shalll furnish material and labor as required to remove existing insulation from secondary chilled water pump supplies and return lines from pumps to tank bypass, remove and reinsulate primary pumps with split case surrounds which allows access to pumps. Insulation shall be phenolic foam type insulation. Install.020 PVC Jacketing on secondary lines after phenolic installation Interested companies shall submit statements of capabilities electronically to jarvis.washington@va.gov no later than Friday March 11, 2016 @ 10:00 a.m. CST. Also firms shall provide their business size status in accordance with the small business administration website (www.sba.gov) for the referenced NACIS code that fall within. Please provide the below information within you submissions: Vendor name Address Email and Phone Number Cage Code & DUNS Number Business size FSS Contract Number (if the items are on the GSA Schedule) Capabilities Statement Install Phenolic Foam Insulation - Request for Information (RFI)
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/HoVAMC/VAMCCO80220/VA25616N0387/listing.html)
- Document(s)
- Attachment
- File Name: VA256-16-N-0387 VA256-16-N-0387.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2603567&FileName=VA256-16-N-0387-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2603567&FileName=VA256-16-N-0387-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA256-16-N-0387 VA256-16-N-0387.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2603567&FileName=VA256-16-N-0387-000.docx)
- Place of Performance
- Address: Depaerment of Veteran Affairs;Purchasing and Contracting NCO 16;Michael E. DeBakey VA Medical Center;2002 Holcombe BLVD;Houston TX
- Zip Code: 77030
- Zip Code: 77030
- Record
- SN04043540-W 20160310/160308235604-7fc565e22bbc3eb4e861c5ac59c471a6 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |