Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 13, 2016 FBO #5224
SOURCES SOUGHT

J -- East LINAC Segregation and VV3 Cable Repair

Notice Date
3/11/2016
 
Notice Type
Sources Sought
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of Energy, SLAC National Accelerator Lab, SLAC National Accelerator Lab, 2575 Sand Hill Road, Menlo Park, California, 94303, United States
 
ZIP Code
94303
 
Solicitation Number
SLAC264664_VV3_Cable_Repair
 
Archive Date
3/19/2016
 
Point of Contact
Allan P Lazarus, Phone: 6509262425
 
E-Mail Address
lazarusa@slac.stanford.edu
(lazarusa@slac.stanford.edu)
 
Small Business Set-Aside
N/A
 
Description
SLAC National Accelerator Laboratory is seeking electrical contractor services to perform the following. The project location is the LINAC Klystron gallery, Building 002. A. Subcontractor shall provide segregation of medium voltage cables (12.47kV circuits) for East LINAC sectors 21 through sectors 30. 1. Subcontractor shall replace medium voltage switch mechanism with copper busing at K-Subs K11, K12, K13, and K15. Modify busing at KCT2. 2. Subcontractor shall provide 12.47kV medium voltage cable splicing and new 12.47kV medium voltage cables in manhole CT2. 3. Subcontractor shall provide cable testing of 12.47kV medium voltage cables C1 and C4 cable. B. Subcontractor shall provide testing and repair of medium voltage VV3 cable in manhole 12. 1. Subcontractor shall provide 12.47kV medium voltage cable splicing of VV3 cable and new 12.47kV medium voltage VV3 cables in manhole 12. C. All workers performing work inside manhole shall be trained for confined space work per OSHA standards. D. Subcontractor shall provide medium voltage cable testing of circuits VV3, C1, and C4 per "SLAC-I-708-404-061-00" medium voltage cable diagnostic testing procedure document. 1. Remove cable terminations for testing and re-terminate cables after testing. 2. Ensure all cable terminations are re-torqued and provided with torque-seal. E. Subcontractor shall provide all required manhole accessories to accommodate cable work in manholes, including but not limited to non-metallic cable racks, rack supports, anchorage, ground jumpers to cable shields, and etc. F. Subcontractor shall furnish and install all materials and equipment and provide all labor required and necessary to complete the work shown the drawings, and/or specifications, and other miscellaneous items, not specifically mentioned, but reasonably inferred for a complete installation, including all accessories and appurtenances required for testing the system. It is the intent of the drawings and specifications that all systems be complete and ready for operation. The on-site work is planned to begin on May 17, 2016 and complete by May 24, 2016. This is not a Request for Proposal or solicitation. Prospective subcontractors must possess current California state contractor licenses for the described work. Prospective subcontractors are invited to registed as Interested Vendors for consideration.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/SLAC/STAN/SLAC264664_VV3_Cable_Repair/listing.html)
 
Place of Performance
Address: 2575 Sand Hill Rd, Menlo Park, California, 94025, United States
Zip Code: 94025
 
Record
SN04047552-W 20160313/160311234323-9f3167f7f968a3890563f00d3325d840 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.