Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 19, 2016 FBO #5230
MODIFICATION

65 -- Oxygen_Masks_and_Nasal_Cannulas - IA FBO Package Worksheet

Notice Date
3/17/2016
 
Notice Type
Modification/Amendment
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
Defense Logistics Agency, DLA Acquisition Locations, DLA Troop Support - Medical, 700 Robbins Avenue, Philadelphia, Pennsylvania, 19111-5096, United States
 
ZIP Code
19111-5096
 
Solicitation Number
IAE-1406-10
 
Point of Contact
Mr. Tom Winkel, Phone: 011-49-6371-9464-4089, Ms. Gabrielle Burns, Phone: 011-49-6371-9464-4933
 
E-Mail Address
thomas.p.winkel.ctr@mail.mil, gabrielle.m.burns2.ctr@mail.mil
(thomas.p.winkel.ctr@mail.mil, gabrielle.m.burns2.ctr@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
Complete pricing offer and vendor information must be submitted in full to the MMESO POCs by the response date of this Sources Sought Notification. Vendors not currently on the QSL for the product line will not be considered for IA. Vendor pricing and packaging MUST match those that were submitted and qualified to the QSL. Use these instructions to complete the IA FBO Package Worksheet. Vendors who are not selected will be notified in writing upon issuance of an IA. The Defense Health Agency (DHA) Medical Logistics (MEDLOG) Division Medical Materiel Enterprise Standardization Office (MMESO) and the Defense Logistics Agency (DLA) Troop Support Medical Prime Vendor (PV) Program announce a Standardization Action (SA) for the standardization of Oxygen Masks and Nasal Cannulas. Only those vendors on the Qualified Suppliers List (QSL) ME-1406-10_Oxygen_Masks_and_Nasal_Cannulas are eligible for participation. The MMESO Europe is the lead MMESO for this project. These Oxygen Masks and Nasal Cannulas products are for purchase by the Military Treatment Facilities (MTFs) of the Military Health System (MHS) and for the operational assemblages of the Army, Navy, Air Force, Marine Corps, and Naval Expeditionary Medical Support Command (NEMSCOM) and managed regionally by MMESOs North, South, West, Pacific and Europe, hereafter referred to as MMESOs. The Incentive Agreement (IA) resulting from this Sources Sought Notification is a supplement to the Prime Vendor (PV) Program and is not a contract. For additional information regarding DLA Troop Support Medical's PV program please access the web site at https://www.medical.dla.mil/. This Sources Sought Notification is intended to solicit pricing quotes from vendors who are on the ME-1406-10_Oxygen_Masks_and_Nasal_Cannulas QSL. The pricing that is provided must be discounted from Distribution and Pricing Agreement (DAPA) prices or proposed DAPA prices. Vendors who are currently qualified for the QSL must meet the requirements below. The resulting IA will be for a base period of two (2) years (24 months) from date of selection, with three (3) 12-month "option" periods not to exceed a total of 5 years. Anticipated selection date is May 2016. Among vendors who are on the ME-1406-10_Oxygen_Masks_and_Nasal_Cannulas QSL, best price will determine selection. It is intended that the selected vendor(s) for this IA will support the enterprise goal of medical materiel standardization that combines operational and institutional requirements. The government is seeking a single vendor selection for an IA. The government reserves the right to standardize or not standardize on Oxygen Masks and Nasal Cannulas. A. Products & Performance Required. The MMESOs are seeking product line items in the category of Oxygen Masks and Nasal Cannulas. The total estimated enterprise-wide annual demand for this product line is approximately $529,186.33 based on Medical Product Data Bank (MedPDB) usage data over a recent 12-month period. The usage data represents requirements for the Army, Navy, and Air Force Institutional MTFs, along with operational assemblages in the Department of Defense (DoD). The specifications for this project are shown in Requirements below. B. Instructions to Vendors Vendors on the ME-1406-10_Oxygen_Masks_and_Nasal_Cannulas QSL who are interested in participating in the Standardization Action for an IA must provide a response to this Sources Sought Notification via e-mail to the MMESO POCs below. In addition to the offered pricing as specified, please include the following information: (1) Company name and address; (2) Company POC (Name and Phone Number, Fax Number, and E-mail address); (3) Commercial and Government Entity (CAGE) Code; and (4) Identification of the Sources Sought notification to which the vendor is responding. Due to the potential for e-mail to be lost in transmission, from network security, etc., vendors are strongly encouraged to confirm with the MMESO Pacific that the submission and quote were received by the MMESO Pacific via e-mail, allowing adequate time for resubmission before the due date and time should a problem occur with the first submission. Vendor must complete and submit the IA FBO Package Worksheet. A vendor who cannot open the IA FBO Package Worksheet may contact either of the MMESO POCs below and a copy will be provided via an alternate method (fax, email or hard copy). Vendors that do not meet the deadline of COB 5:00 PM Hawaii Standard Time (HST) on the date listed for closing, per the FBO Sources Sought notification, will not be eligible for participation in the Standardization Action for an Incentive Agreement. C. Source Selection Procedures Pricing analysis of required items will occur for those vendors who have been previously qualified for the QSL. Price will be evaluated based on unit price multiplied by number of estimated units. Best overall price will be the determining factor in vendor selection for an Incentive Agreement for Standardization. Quotes should contain the vendor's best discounts off of the vendor's DAPA pricing. The Government intends to make a selection based on initial quotes but reserves the right to conduct discussions and request revised quotes, if determined necessary. Vendor Instructions for Pricing Submission The pricing requirements are outlined below. Complete pricing offer and vendor information must be submitted in full to the MMESO POCs by the response date of this Sources Sought Notification. Vendor pricing and packaging MUST match those that were submitted and qualified to the subject QSL FBO. Vendors not currently on the subject QSL will not be considered for an IA. Use these instructions to complete the IA FBO Package Worksheet. Vendors who are not selected will be notified in writing upon issuance of an IA. 1.Vendor must submit the following information via IA FBO Package Worksheet for each QSL required item: Vendor Part Number (PN), Manufacturer PN, Manufacturer Name, Full Item Description, DAPA Number for Item, Unit of Measure (UOM), Quantity (QTY) in UOM, Unit of Inner Packaging (UOP), QTY of UOM in UOP, Unit of Sale (UOS), QTY of UOM in UOS, UOS Base Price, UOS Incentive Price, UOM Base Price and UOM Incentive Price. Item Descriptions /Annual Usage in Units (Individual Wipes) / 1.ADULT NASAL CANNULA WITH 7 FOOT LONG CRUSH RESISTANT TUBING /231,632 / 2.ADULT ELONGATED MEDIUM CONCENTRATION OXYGEN FACE MASK WITH 7 FOOT LONG TUBING AND WITH SAFETY VENT(S) OR REMOVABLE VENT COVER(S) /144,568 / 3.ELONGATED OR SHORT STYLE HIGH CONCENTRATION ADULT REBREATHER OXYGEN MASK WITH 7 FOOT LONG TUBING AND SAFETY VENT(S) OR REMOVABLE VENT COVER(S) /108,700 / 4.ADULT NON-REBREATHER ELONGATED OXYGEN MASK WITH 7 FOOT LONG TUBING AND SAFETY VENT(S) OR REMOVABLE VENT COVER(S) /34,872 / 5.ELONGATED AEROSOL ADULT OXYGEN MASK WITH SAFETY VENT(S) OR REMOVABLE VENT COVER(S) /17,100 / 6.PEDIATRIC NON-REBREATHER OXYGEN MASK WITH 7 FOOT LONG TUBING AND SAFETY VENT(S) OR REMOVABLE VENT COVER(S) /16,685 / 7.ELONGATED PEDIATRIC AEROSOL OXYGEN MASK WITHOUT TUBING AND SAFETY VENT(S) OR REMOVABLE VENT COVER(S) /9,120 / 8.ADULT NON-REBREATHER OXYGEN MASK WITH 7 FOOT LONG TUBING, WITHOUT SAFETY VENT OR WITH COVERED VENT(S) /7,029 / 9.ADULT NASAL CANNULA WITH 13 - 15 FOOT LONG CRUSH RESISTANT TUBING /6,550 / 10.ADULT NASAL CANNULA WITH 20 - 25 FOOT LONG CRUSH RESISTANT TUBING /5,700 / 11.ELONGATED OR SHORT MEDIUM CONCENTRATION PEDIATRIC OXYGEN FACE MASK WITH 7 FOOT LONG TUBING AND SAFETY VENT(S) OR REMOVABLE VENT COVER(S) /2,250 / 12.ADULT NASAL CANNULA WITH 4 - 5 FOOT LONG CRUSH RESISTANT TUBING /100 / 2.Vendor may provide any or all of the additional items listed below, following the same format as for requirement number 1. Pricing for these additional items will not be part of the pricing computation for vendor selection. All additions will be at the discretion of the Government. Item Descriptions / 1.ADULT NASAL CANNULA WITH 7 FOOT LONG CRUSH RESISTANT TUBING WITH ELASTIC HEAD STRAPS / 2.PEDIATRIC AEROSOL OXYGEN MASK WITH 7 FOOT LONG TUBING, AND SAFETY VENT(S) OR REMOVABLE VENT COVER(S) / 3.ADULT NASAL CANNULA WITH 50 FOOT LONG CRUSH RESISTANT TUBING / 4.ADULT ELONGATED OR SHORT STYLE 3-IN-1 OXYGEN MASKS WITH MEDIUM CONCENTRATION AND NON-REBREATHER WITH 7 FOOT LONG TUBING AND WITH SAFETY VENT(S) OR REMOVABLE VENT COVER(S) / 5.ADULT ELONGATED OR SHORT STYLE 3-IN-1 OXYGEN MASKS WITH HIGH CONCENTRATION AND NON-REBREATHER WITH 7 FOOT LONG TUBING AND WITH SAFETY VENT(S) OR REMOVABLE VENT COVER(S) / 6.ADULT HIGH CONCENTRATION REBREATHER OXYGEN MASK WITH SAFETY VENT(S) OR REMOVABLE VENT COVER(S) AND 14 FOOT LONG TUBING / 7.ADULT NASAL CANNULA WITH 1 - 2 FOOT LONG CRUSH RESISTANT TUBING / 8.ADULT NASAL CANNULA WITH 100 FOOT LONG CRUSH RESISTANT TUBING / 9.ADULT NASAL CANNULA WITH 16 FOOT LONG CRUSH RESISTANT TUBING / 10.ADULT NASAL CANNULA WITH 30 - 35 FOOT LONG CRUSH RESISTANT TUBING / 11.ADULT NASAL CANNULA WITH 40 FOOT LONG CRUSH RESISTANT TUBING / 12.ADULT NASAL CANNULA WITH 75 FOOT LONG CRUSH RESISTANT TUBING / 13.ADULT NASAL CANNULA WITH 9 - 12 FOOT LONG CRUSH RESISTANT TUBING / 14.ADULT OPEN DESIGN OXYGEN MASK WITH ADJUSTABLE FIO2 BETWEEN 24%-90% AND 7 FOOT LONG TUBING / 15.ADULT OPEN DESIGN OXYGEN MASK WITH ADJUSTABLE FIO2 BETWEEN 24%-90%, EAR ELASTICS, AND 7 FOOT LONG TUBING / 16.ADULT TRACHEOSTOMY OXYGEN MASK WITH STRAP AND SWIVEL CONNECTOR / 17.ADULT VENTURI OXYGEN MASK WITH 7 FOOT LONG TUBING, 6 DILUTER KIT FOR ADJUSTABLE FIO2 BETWEEN 24%-50% WITH SAFETY VENT(S) OR REMOVABLE VENT COVER(S) / 18.ADULT VENTURI OXYGEN MASK WITH 7 FOOT LONG TUBING, DIAL FOR ADJUSTABLE FIO2 BETWEEN 24%-50% OR ADJUSTABLE FIO2 BETWEEN 24% - 55% WITH SAFETY VENT(S) OR REMOVABLE VENT COVER(S) / 19.EXTRA LARGE ADULT ELONGATED AEROSOL OXYGEN MASK WITH 7 FOOT LONG TUBING AND SAFETY VENT(S) OR REMOVABLE VENT COVER(S) / 20.EXTRA LARGE ADULT ELONGATED MEDIUM CONCENTRATION OXYGEN FACE MASK WITH 7 FOOT LONG TUBING AND SAFETY VENT(S) OR REMOVABLE VENT COVER(S) / 21.INFANT AEROSOL OXYGEN MASK / 22.INFANT NON-REBREATHER OXYGEN MASK WITH 7 FOOT LONG TUBING AND SAFETY VENT(S) OR REMOVABLE VENT COVER(S) / 23.LARGE ADULT OPEN DESIGN OXYGEN MASK WITH ADJUSTABLE FIO2 BETWEEN 24%-90% AND 7 FOOT LONG TUBING / 24.PEDIATRIC NON-REBREATHER OXYGEN MASK WITH 7 FOOT LONG TUBING, WITHOUT SAFETY VENT OR WITH COVERED SAFETY VENT(S) / 25.PEDIATRIC OPEN DESIGN OXYGEN MASK WITH ADJUSTABLE FIO2 BETWEEN 24%-90% AND 7 FOOT LONG TUBING / 26.PEDIATRIC SHORT OR ELONGATED HIGH CONCENTRATION REBREATHER OXYGEN MASK WITH 7 FOOT LONG TUBING AND SAFETY VENT(S) OR REMOVABLE VENT COVER(S) / 27.PEDIATRIC SHORT OR ELONGATED HIGH CONCENTRATION REBREATHER OXYGEN MASK WITH 7 FOOT LONG TUBING WITHOUT SAFETY VENT OR WITH COVERED VENT(S) / 28.PEDIATRIC TRACHEOSTOMY OXYGEN MASK WITH STRAP AND SWIVEL CONNECTOR / 29.PEDIATRIC VENTURI OXYGEN MASK WITH 7 FOOT LONG TUBING, 6 DILUTER KIT FOR ADJUSTABLE FIO2 BETWEEN 24%-50% WITH SAFETY VENT(S) OR REMOVABLE VENT COVER(S) / 30.PEDIATRIC VENTURI OXYGEN MASK WITH 7 FOOT LONG TUBING, DIAL FOR ADJUSTABLE FIO2 BETWEEN 24%-50% WITH SAFETY VENT(S) OR REMOVABLE VENT COVER(S) / 31.TRACHEOSTOMY ENTRAINMENT ADULT OXYGEN MASK WITH 7 FOOT LONG TUBING, 5 DILUTER KIT FOR ADJUSTABLE FIO2 BETWEEN 24% - 40% / 32.TRACHEOSTOMY ENTRAINMENT ADULT OXYGEN MASK WITH 7 FOOT LONG TUBING, 6 DILUTER KIT FOR ADJUSTABLE FIO2 BETWEEN 24% - 50% / 33.PEDIATRIC NASAL CANNULA WITH 7 FOOT LONG CRUSH RESISTANT TUBING / 34.INFANT NASAL CANNULA WITH 7 FOOT LONG CRUSH RESISTANT TUBING / 35.NEONATAL NASAL CANNULA WITH 7 FOOT LONG CRUSH RESISTANT TUBING / 3.Vendor will be required to submit discounts off of DAPA for all products included in this standardization initiative. Where lower base uncommitted government prices are available, such as Federal Supply Schedule (FSS) prices, incentive tier is expected to be lower than such prices. This is because DAPAs, unlike other government prices, are base uncommitted. A vendor shall not quote base uncommitted prices such as FSS prices as the discounted tier price for purposes of this standardization initiative. Vendor must provide quotes on items provided in response to the technical/company requirements. Based on the good faith volume estimates provided, vendor agrees to give all designated MTFs and Operational Units incentive pricing throughout the life of this agreement in exchange for 80% commitment of purchases for the MHS in this product line. A vendor who does not provide discounts off DAPA in response to the IA FBO will not be considered for continued participation. Points of Contact (POCs): Mr. Tom Winkel, MMESO Europe Team Leader, thomas.p.winkel.ctr@mail.mil, 011-49-6371-9464-4089; and Ms. Gabrielle Burns, RN, BSN, MMESO Europe Clinical Analyst, Gabrielle.m.burns2.ctr@mail.mil, 011-49-6371-9464-4933. DLA Troop Support Medical Contracting Officer: Ms. Tara J. Perrien, tara.perrien@dla.mil (215) 737-8307.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DLA/J3/DSCP-M/IAE-1406-10/listing.html)
 
Place of Performance
Address: Medical Materiel Enterprise Standardization Office (MMESO) Europe, ERMC HQ, CMR 402 box 219, Dept G4, Bldg 3739, Rm 222, Landstuhl, Rhineland-Palatinate, Non-U.S. APO 09180-0003, Germany
 
Record
SN04053587-W 20160319/160317234634-1341e4503fbcfa76bc433a97a1050897 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.