Description
HEMODIALYSIS MACHINES Shreveport VAMC is in need of 6 new Fresenius 2008K or equal hemodialysis machines. They should meet all the salient characteristics below. Onsite training and installation is required. Salient characteristics: oOperational performance: "Ability to have Crit-Line monitoring "Heat disinfection: "Temperature: 83 ±8 °C "Flow Rate: 600 ml/min. "Time: Between 10 and 60 minutes (internally selectable) "Chemical Disinfection: "Temperature:37 °C (set point applicable) "Flow Rate:620 ml/min. "Time:Between 10 and 60 minutes (internally selectable) oElectrical: "Power Supply - Main: AC 117V +/-10% 60 Hz "Power Consumption: Does not exceed 1.5 amps "External Connections: Isolated RS3 and Ethernet ports; leakage current isolation per UL 60601-1 between the machine and external computer oWater: "Ingress Rating: IPXI (Vertical drip-proof protection) "Back Flow Prevention: Integral back flow prevention provided by external vet to atmosphere in water inlet circuit "Water Pressure: Min 0 psi; max 105 psi "Water Temperature: Min 10 °C; max S °C "Quality: AAMI Standar, RD6;006 and RD5:004, Dialysate for Hemodialysis "Drain: 3 feet maximum height. Must comply with local codes and must maintain a free fall air gap between drain hose and building drain. "Temperature 37 °C. Flow rate 60 ml/min. Time between 10 and 60 minutes (internally selectable) oDialyzing Fluid: "Dialysate Flow: Dialysate Flow button "Adjustment Range: Accuracy: ±5% "Sequential (0)/100/200/300/400/500/600/700/800 ml/min.,selectable in the Dialysis screen; "Additionally: 1.SX or 2X dialysate flow rate based on the Blood Pump rate (Qb): "Concentrate Pressure:Max suction height 3 feet "Max supplied pressure 2 psi "Acid Adjustment Range: 130 to 155 mEq/L Na+ "Bicarbonate Adjustment Range: 20 to 40 mEq/L Bicarbonate "Range of Display: 10.0 to 17.0 ms/cm.At 25 °C.Alarm limits will not go below 12.5 or above 16.0 mS/cm. "Dialysate Temperature: Selectable from 35 to 39 °C oUltrafiltration Control: "UF Pump Volume Accuracy: ±1% (for Pdi > -500 mbar) where Pdi = dialysate pressure on the inlet side of the dialyzer "Fluid Removal Rate from Patient: 0 - 4000 ml/hr "UF Profiles: Eight UF profiles are available for the removal of fluid from the patient. Four are preset and four may be defined by the user. oBlood Circulation: "Blood Pump "Display of blood flow: 6 -600 ml/min "Internal diameter of rate blood pump segment 2.6, 4.8, 6.4, 8.0 mm "Heparin Pump: "Type of Syringe: 10 -12 ml disposable syringe "Administration Rate: 0 to 9.9 ml/hr "Arterial Pressure Monitor: -300 to +500 mmHg "Venous Pressure Monitor: -80 to +500 mmHg "TMP Monitor: +60 to -520 mmHg "Level detector:Ultrasonic impulses detect fluid level in the drip chamber "Blood Leak Detector: Two color light source transmitter I sensor with a resolution of: ominor > 0.35 ml/min. of blood (hematocrit = 25%) oalarm > 0.45 ml/min. of blood (hematocrit = 25%) oAccess Flow (Qa): Maximum Qa: 2000
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/AlVAMC502/AlVAMC502/VA25616Q0435/listing.html)
 
Document(s)
Attachment
 
File Name: VA256-16-Q-0435 VA256-16-Q-0435_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2625339&FileName=VA256-16-Q-0435-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2625339&FileName=VA256-16-Q-0435-000.docx

 
File Name: VA256-16-Q-0435 VA256-16-Q-0435.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2625340&FileName=VA256-16-Q-0435-001.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2625340&FileName=VA256-16-Q-0435-001.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: DEPARTMENT OF VETERANS AFFAIRS;OVERTON BROOKS VAMC;510 E STONER AVE;SHREVEPORT, LA
Zip Code: 71101
 
Record
SN04055018-W 20160320/160318234720-8f7f0fbb034ddd5966086189d9328cca (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.