DOCUMENT
65 -- Sources Sought: Multilab Vascular System - Attachment
- Notice Date
- 3/23/2016
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Dayton VA Medical Center;3140 Governor ™s Place Blvd. Suite 210;Kettering OH 45409-1337
- ZIP Code
- 45409-1337
- Solicitation Number
- VA25016Q0187
- Response Due
- 3/28/2016
- Archive Date
- 4/27/2016
- Point of Contact
- John Tschirhart
- Small Business Set-Aside
- Total Small Business
- Description
- This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of Small Businesses, including 8(a), Hub Zone and Service Disabled Veteran-Owned firms relative to the North American Industry Classification Code (NAICS) 339112.The Department of Veteran's Affairs is seeking small business manufacturer or distributors of small business manufacturers, of functionally equivalent equipment to all the following: This system will be used in our Vascular Lab as a Noninvasive Diagnostic tool which will enable us to accurately determine the presence of disease in our veteran population that are vasculopaths. FEATURING UNETIXS' ADVANCED AUTO SEQUENCE SOFTWARE AND TOUCH SCREEN CONTROLS, INCORPORATING: - Dual Channel Calibrated Pneumoplethysmography - Arterial (PVR) - Dual Channel Photo plethysmography - Arterial & Venous, featuring dual auto inflation with selectable auto bleed for pressure studies. - Bi-Directional Stereo Doppler - Tower CPU Featuring Windows 7 OS - 17" Flat Screen Color Touch Monitor - Hospital Isolated Power Module Includes the following Standard System Accessories 1 Trudop - 5 MHz Doppler Probe 1 TruDop - 8 MHz Doppler Probe 1 8' Doppler Cable 2 Unique Miniature PPG Sensors 1 Parallel Serial Cable 1 Windows 7 OS 1 Color Printer 1 Custom Cart includes Storage Drawer, Locking Dual Casters, Integrated Function Keyboard & Compartment for Color Printer and CPU 1 Wireless Remote Control 1 10 Cuff AutoCuff Automated Cuff Selector 1 Bottle Ultrasound Gel 1 A B 6 - SC-10 Blood Pressure Cuff 6 - SC-10 Blood Pressure Cuff 4 - SC-12 Blood Pressure Cuff 2 - CC-17 Blood Pressure Cuff 2 - SC-12L Blood Pressure Cuff Long 2 - TMC-7 Transmetatarsal Cuff 2 - PC-2.5 Digit Pressure Cuff 2 - PC-2.5 Digit Pressure Cuff 1 MultiLab Series 2 LHS Installation Guide 2 MultiLab Series 2 Operator's Manual 2 MultiLab Series 2 Service Manual 1 Vascular Technological Book compatibility with the GE Vivid T8 ultrasound system. THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 339112 (Surgical and Medical Instrument Manufacturing). Responses are to be submitted by e-mail to john.tschirhart@va.gov. No later than 03/28/2016 @ 10 A.M. Email should contain the following information: Name of firm, Socio-Economic category of the firm (SDVOSB, VOSB, 8A, HUBZONE or SMALL BUSINESS), complete address, phone & fax number of contact.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/DaVAMC552/DaVAMC552/VA25016Q0187/listing.html)
- Document(s)
- Attachment
- File Name: VA250-16-Q-0187 VA250-16-Q-0187.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2632516&FileName=VA250-16-Q-0187-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2632516&FileName=VA250-16-Q-0187-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA250-16-Q-0187 VA250-16-Q-0187.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2632516&FileName=VA250-16-Q-0187-000.docx)
- Place of Performance
- Address: Dayton VAMC;4100 West Third Street;Dayton Ohio
- Zip Code: 45428-9000
- Zip Code: 45428-9000
- Record
- SN04059854-W 20160325/160323235232-2b98120c0d243457f50c243945dd43ab (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |