Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 30, 2016 FBO #5241
MODIFICATION

Z -- Repair Outdoor Swimming Pool

Notice Date
3/28/2016
 
Notice Type
Modification/Amendment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Air Force, Air Force Global Strike Command, 7 CONS, 381 Third Street, Dyess AFB, Texas, 79607-1581, United States
 
ZIP Code
79607-1581
 
Solicitation Number
FA4661-16-R-0008
 
Point of Contact
Lydia K. Simpkins, Phone: 3256963863, Benjamin M. Brown, Phone: 3256962288
 
E-Mail Address
lydia.simpkins@us.af.mil, benjamin.brown.16@us.af.mil
(lydia.simpkins@us.af.mil, benjamin.brown.16@us.af.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Questions & Answers: 1.)What is the approved epoxy, and is it required or can we use a multi-flex paint? Which is an elastic water sealer that will seep in and seal the cracks. Any epoxy that is used for structural concrete repairs. No, a paint is not going to be used to seal a crack. 2.)Is the kiddie pool part of the contract? No. 3.)Why was the pool half full at time of walk through? Because CE drained the pool halfway. 4.)Are there any known leaking issues? Yes. 5.)When was the pool last fully functioning? It functioned throughout last year's pool season. 6.)When was it last re-plastered? CE states that it was 2009. 7.)Are filter pumps fully functioning and can you verify they are? They are fully functional. 8.)Is there a pool maintenance log we can see? Any past history of pool performance would be beneficial. There is not. CE states that the pool was built in 2004, plastered 2009, and I believe all equipment is original. 9.)Do all lights work and can you verify they do? No light replacement was mentioned in SOW. Lights will not be in the contract. 10.)Are there any known plumbing issues? Not that we know of. 11.)Can we spray our bond-kote on instead of rolling? We have rolled it on before and it's not rough enough, it should be sprayed on to allow a better adhesion with the new plaster. Apply to manufacturer specifications. 12.)Does it need to be sealed around the Lights and Drains? A few lights had water in them. No. 13.)At walk through it was stated that the chlorinator supply line saddle would stay as is, and pipe was to be replaced above existing saddle eliminating any concrete demo to remove piping is this correct? All piping will be replaced, new saddle tap will have to be installed. 14.)SOW only refers to the pool itself with pumps and equipment. The surrounding decking and pool appurtenances are not part of this SOW? Correct. 15.)There were broken Depth Number Tiles do they need to be replaced? If so can we get pics and/or a total count on tiles to be replaced? No. 16.)Depth number stickers were torn/damaged. Do these need to be replaced? No. 17.)Existing Grates for Pool Gutter had a coating that was flaking. Do these get replaced? No.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/df1fc6f434f9974d43991e4f6f0a6772)
 
Place of Performance
Address: 381 Third Street, Dyess AFB, Texas, 79607, United States
Zip Code: 79607
 
Record
SN04064136-W 20160330/160328234204-df1fc6f434f9974d43991e4f6f0a6772 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.