J -- Preventative and Emergency Maintenance Service for Uninterruptible Power Systems (UPS)

Notice Date
4/7/2016
 
Notice Type
Sources Sought
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B130, Gaithersburg, Maryland, 20899-1410, United States
 
ZIP Code
20899-1410
 
Solicitation Number
NB193000-16-00753ss
 
Archive Date
5/5/2016
 
Point of Contact
Michelle L. Dacanay, Phone: 3019753682, Sandra Smith, Phone: 3019756646
 
E-Mail Address
michelle.dacanay@nist.gov, sandra.smith@nist.gov
(michelle.dacanay@nist.gov, sandra.smith@nist.gov)
 
Small Business Set-Aside
N/A
 
Description
Notice Number: NB193000-16-00753ss Title: Preventative and Emergency Maintenance Service for Uninterruptible Power Systems (UPS) NAICS Code: 238210 National Institute of Standards and Technology(NIST) is issuing this sources sought notice as a means of conducting market research, pursuant to FAR Part 10 Market Research, to identify potential parties capable of performing Preventative and Emergency Maintenance Service on ANY or ALL Uninterruptible Power Supply (UPS) Systems identified in the sources sought. This is a SOURCES SOUGHT ONLY, not a Request for Proposals (RFP) and does not commit the Government to award a contract now or in the future. The purpose of this sources sought is to identify organizations with the capabilities to provide the services stated herein. Submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. WOSB, HUBZone, and VOSB and SDVOSB are encouraged to respond to this notice. BACKGROUND NIST has several small to medium size UPS systems installed in various locations on campus that supply uninterrupted clean power to critical loads on campus. The purpose of these systems is to provide power long enough to permit a controlled shut down in the unlikely event of a total loss of utility power. The UPS systems requires a preventative and emergency maintenance service plan. The service plans shall be Original Equipment Manufacturer (OEM) and the work performed on the equipment shall be performed by OEM factory trained personnel. LIST OF UPS SYSTEMS Manufacturer Models APC SILCON 10KW EATON 9315-100-160 EATON 9390-40-80 EATON 9390-40-80 EATON 9390-40-80 LIEBERT NRA40CCSAFAOS70 MGE EPS 225 KVA MGE EPS 300 KVA MGE EPS 375 KVA MGE EPS 6000 WRAP AROUND CAB MGE GALAXY 3000 MGE GALAXY 5000 MGE GALAXY PW 150 KVA TOSHIBA 100 KVA Interested, capable vendors (parties) shall submit a Capability Statement in response to this Sources Sought Notice, with the following: 1. Contact information: Company, Address, Point of Contact, Phone Number, Fax Numbers, Email Address 2. Type of business (small, large, etc.) with a brief summary of the company, of no more than 3 paragraphs. 3. Evidence that the interested party is fully capable of providing the required service and supplies for ANY or ALL UPS Systems and as such may contain any information that the interested party feels is relevant. 4. Please address any concerns that you have pertaining to this notice that should be clarified by the Government prior to the issuance of a solicitation. NOTE: The total number of pages to reply to this source sought shall not exceed 10 pages double-sided and shall be submitted via https://www.FBO.gov. No other capability statements will be accepted. NOTE: All vendors need to be registered in SAM for contract award. www.sam.gov A SOLICITATION IS NOT CURRENTLY AVAILABLE. The Government is not obligated and will not pay for any information received from potential sources as a result of this sources sought. If and when a solicitation is issued it will be posted on GSA e-Buy or https://www.fbo.gov/. It is the respondent's responsibility to monitor this site for the release of any synopsis or solicitation. Vendors are not required to respond to this notice to be considered for award. No phone calls will be accepted for this notice. All questions may be addressed to Michelle Dacanay at michelle.dacanay@nist.gov with the subject line that reads "Sources Sought Notice: UPS Systems".
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/NB193000-16-00753ss/listing.html)
 
Place of Performance
Address: National Institute of Standards and Technology, 100 Bureau Drive, Bldg. 301, Gaithersburg, MD 20899, Gaithersburg, Maryland, 20899, United States
Zip Code: 20899
 
Record
SN04076876-W 20160409/160407234958-0eaf47dfc78302ab815d56a707995a22 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.