Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 10, 2016 FBO #5252
SOLICITATION NOTICE

66 -- Laboratory Equipment for Alaska

Notice Date
4/8/2016
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333249 — Other Industrial Machinery Manufacturing
 
Contracting Office
Defense Logistics Agency, DLA Acquisition Locations, DLA Energy, 8725 John J. Kingman Road, Fort Belvoir, Virginia, 22060-6222, United States
 
ZIP Code
22060-6222
 
Solicitation Number
SP0600-16-Q-0244
 
Point of Contact
Zulma L. Irizarry, Phone: 7037678210, DLA Energy PEC, Fax: 703-767-8506
 
E-Mail Address
zulma.irizarry@dla.mil, DLAEnergyPEC@dla.mil
(zulma.irizarry@dla.mil, DLAEnergyPEC@dla.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6 of the Federal Acquisition Regulations (FAR), as supplemented with additional information included in this notice. Offers are being requested and a written solicitation will not be issued. The contract resulting from this procurement will be a firm fixed price contract. The solicitation SP0600-16-Q-0244 is issued as a Request for Quotation (RFQ), under the Simplified Acquisition Procedures (SAP), Part 13, specifically subpart 13.5 Simplified procedures for Certain Commercial items. This document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-87 dated 16 March 2016. DPAS rating for potential award is DO. The clauses and provisions referenced in this solicitation may be reviewed/obtained in full text form at http://farsite.hill.af.mil/vffara.htm. Schedule CLIN 0001 Nomenclature: Existent Gum Bath, Jet Fuel Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D381, Gum Content in Fuels by Jet Evaporation. Must have 6 sample positions or stations - no more, no less. Should be constructed of a machined aluminum block with multiple cartridge heaters. Must have a pressure regulator and an air flowmeter built-in as a single unit. Must be 220-240V, 50/60Hz, Single Phase, and not more than 15A. Dimensions must less than 29"Lx21"Wx17"D to accommodate available space. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Koehler Instruments, Model: K33700 Existent Gum Evaporation Bath CLIN 0002 Nomenclature: Ellipsometer, Jet Fuel Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D3241, Thermal Oxidation Stability of Aviation Turbine Fuels (JFTOT Procedure) for heater tube rating procedure. Must rate the heater tube as pass/fail as well as measure deposits - deposit thickness ranging 0 to 500 nm, deposit volume ranging 0 to 0.5 mm3. Must be 110/115V. Dimensions must less than 12w x 20d to accommodate available space. Height is unrestricted. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Alcor, Model: OptiReader CLIN 0003 Nomenclature: Microseparomter, Automated, Jet Fuel Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D3948, Determining Water Separation Characteristics of Aviation Turbine Fuels by Portable Separometer. Must be available in 115V +/- 10v. Should be portable and contain a rechargeable battery. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Emcee, Model: 1140 Micro-Separometer CLIN 0004 Nomenclature: Bath, Copper Strip Corrosion, Jet and Diesel Fuel Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D130, Corrosiveness to Copper from Petroleum Products by Copper Strip Test. Bath should have digital, temperature controller and some form of circulation of bath media. Must have 8 openings to run 8 individual samples, a Soxhlet reflux condenser, and constant water level viewing tube. Bath must be capable of reaching a minimum of 100C. Must be available in 115V 60Hz, Single Phase, and no more than 8A. Required dimensions not more than 18 "Lx 13"W. Height is not restricted Bath's liquid media must be water or water/antifreeze mixture. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Koehler Instruments, Model: K25320 ASTM D130 Copper Strip Corrosion Test Bomb Bath CLIN 0005 Nomenclature: COLORIMETER, Automated, Jet Fuel Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D156, Saybolt Color of Petroleum Products and D6045, Color of Petroleum Products by the Automatic Tristimulus Method. Must be available in 115V. Required dimensions not more than 22 "W x 10"D and weigh less than 20lbs. Height is not restricted. Interface should have USB, LAN, RS232 and be programed for remote calibration and maintenance via the internet. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG LOVIBOND, Model: PFX195 i /2 Saybolt Color of Jet Fuel CLIN 0006 Nomenclature: Centrifuge, Tabletop, Diesel Fuels Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D2709, Water and Sediment in Middle Distillate Fuels by Centrifuge. Should be a 4 position, tabletop centrifuge. Should contain 4 trunnions, 4 individually heated D model cups, include a built-in tachometer, a hand brake, and designed for Class 1, Group D, Division 2. Height is not restricted however; the unit must fit a 28" x 28" space. Should weigh less than 160 lbs. Must be 115V +/- 10v. Accessories to be included are 100ml Long Cone Tubes(PK of 6), marked in milliliters every 1ml above 10ml. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Milton Lab Model Centrifuge or Benchmark 2000 Lab Model Centrifuge CLIN 0007 Nomenclature: Jet Fuel Thermal Oxidation Tester, Jet Fuel Unit of Issue: EA Quantity: 0001 Description: Shall adhere to ASTM D3241, Thermal Oxidation Stability of Aviation Turbine Fuels (JFTOT Procedure). The Tester should be parts compatible with our current JFTOT III manufactured by Alcor to maximize parts interchangeability and calibration needs. It should be the most current generation model, the JFTOT IV. Should be so automated as to significantly reduce operator interface over previous generations by at least 50%. Must be over 18" X 25". Height is not restricted. Weight must be no more than 140 pound. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Alcor: Model: JFTOT IV, Jet Fuel Thermal Oxidation Tester CLIN 0008 Nomenclature: Flash Point Testing Unit, Automatic, Jet Fuel and Diesel Unit of Issue: EA Quantity: 0002 Description: Shall adhere to ASTM D93 Flash Point by Pensky-Martens Closed Cup Method capable of flash point measurements from 30C to 400C and must be compatible with the PS400 Temperature Probe and the Meriam Manometer for calibration. Must use an Electric Igniter with built-in Fire Extinguisher. Power needs are 115V +/- 10V, 50/60 Hz and no more than 1200W. Size must be less than 11"wide x 21"deep. Height is not restricted. Must include Safety Alarm System that detects, as a minimum, automatic detection of method or safety violations and a Safety Pre-dip. A built-in barometric pressure sensor for automatic correction of flash point. An automatic stirrer capable of 0 to 300 RPMs. This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Hertzog: Model: OptiFlash Pensky-Martens Standard Model Gas Igniter CLIN 0009 Nomenclature: Installation, Calibrate, and onsite demonstration Unit of Issue: EA Quaintly: 0001 Description: Offeror to install and calibrate CLIN 0007, and 0008 requirements at DLA Energy Alaska, Petroleum Laboratory, Building 986 Warehouse St, JBER-Richardson AK 99506 in accordance to MFG specification and to provide a demonstration after install and calibration is complete. Note: If not offering on all listed CLINs please identify specifically what CLINs being offered against to meet this requirement. CLIN 0010 Nomenclature: Shipping (if applicable) Unit of issue: EA Quantity: 0001 Description: Applicable to CLINs 0001, 0002, 0003, 0004, 0005, 0006, 0007 and 0008 Shipping address is : DLA Energy Alaska, Petroleum Laboratory, BLDG 986 Warehouse Street, JBER-Richardson, AK 99506 THIS IS NOT AN ALL OR NONE OPPORTUNITY MULTIPLE AWARDS ANTICIPATED Electronic Funds Transfer as a means of payment will be made upon receipt and acceptance of all products through Wide Area Work Flow (WAWF) Reference FAR 52.232-33 and DFARS 252.232-7003. The following provisions and clauses apply to this acquisition: FAR 52-212-1, Instructions to Offerors Commercial Items; 52.212-2 Evaluation of Commercial Items; the evaluation criteria stated in paragraph (a) of the provision are as follows: The significant evaluation factors, in the relative order of importance are: 1. Price 2. Technical specifications, and 3. Past performance. Evaluation factors are approximately equal. The contract award will be offered to the Lowest Price Technically Acceptable offer made to the Government, considering price, technical and past performance. 52.212-3 Offeror Representations and Certifications Commercial Items; 52.212-4, Contract Terms and Conditions Commercial Items and 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive orders - Commercial Items. In paragraph (b) of 52.212-5, the following apply: FAR 52.203-6 ALT 1, 52.204-18, 52.209-6, 52.209-10, 52.219-6, 52.219-8, 28, 52.222-21, 26, 35,37,50, 52.223-18, 52.225-13, and 52.232-34. FAR 52.203-3, 52.204-18, 52.209-7, DFAR 252.203-7005, 252.204-7003, 252.204-7008, 252.204-7011, 252.204-7012, 252.204-7015, 252.209-7004, 252. 223-7006, 252.225-7001, 252.225-7002, 252.225-7020, 252.225-7031, 252.225-7048, 252.232-7003, 252.232-7006, 252.232-7010, 252.243-7001, 252.244-7000 and 252.247-7023. All responsible offerors respond to Zulma Irizarry (zulma.irizarry@dla.mil) NLT 12:00 pm Fort Belvoir local time (EST) May10, 2016 ; Send questions to the Contracting Specialist, Zulma Irizarry, 703-767-8251, FAX: 703-767-8506, or email: zulma.irizarry@dla.mil and DLAEnergyPEC@dla.mil by RFQ NLT date/time. FAX quotations will be accepted.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DLA/J3/DESC/SP0600-16-Q-0244/listing.html)
 
Place of Performance
Address: Alaska, Alaska, United States
 
Record
SN04078114-W 20160410/160408234214-6481bc9d2f307754672c8c691292eafc (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.