Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 18, 2016 FBO #5290
SOLICITATION NOTICE

45 -- BURNERS - Solicitation Sole Source

Notice Date
5/16/2016
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333414 — Heating Equipment (except Warm Air Furnaces) Manufacturing
 
Contracting Office
Department of the Army, Army Contracting Command, ACC - RI (W90WL5) Tooele Contracting Office, PO BOX 839, Tooele, Utah, 84074-5000, United States
 
ZIP Code
84074-5000
 
Solicitation Number
W90WL5-16-T-0013
 
Archive Date
6/2/2016
 
Point of Contact
Farrel E. DeLeeuw, Phone: 4358332327
 
E-Mail Address
farrel.e.deleeuw.civ@mail.mil
(farrel.e.deleeuw.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
Burners Solicitations - Sole Source J & A Complete natural gas burner assembly as described below. The burner fuel and air inlets shall be pre-plumbed assemblies with necessary fittings for operation. Associated fuel trains and blowers will be included for each burner assembly, as well as local control panels. A calibration of the burners will be provided by the vendor after the government has completed install. ThermJet 0750 Model Burner (After Burner System PRJ101029536 Eclipse - no substitution) •7,500,000 Btu/hr •Ambient temperature, no preheat •High velocity outlet•Alloy tube combustor•Natural gas fuel•UV scanner adapter Each burner will have an associated compatible blower and air manifold assembly included. •Blowers will include associated silencer/filter •Pre-piped air manifold assembly includes: properly sized nipple flange; modulating butterfly valve with 4-20mA I/O; and associated purge switch, combustion switch, pressure gauge, and cock valve. Each burner above will have its own skidded fuel/valve train. •1.5 in NPT Main•NEMA 4•Siemens SSOVs•Pressure Switches•Junction Box •Skid orientation to be confirmed with Government•Blowers will have associated silencer/filters Each burner will have a gas burner manifold assembly to include the associated: •Ratio Regulator•Limiting Gas Valve•Flex Nipple/Union Provide NEMA Type 4 control panel for each burner. Does not require a PID controller, as that will be handled through PLC. Items included for each burner assembly: •UV Scanner •Terminal Transformer •Ignition Transformer • Wire, 16 AWG Ignition, High Temp •4-20 mA outputs on controls, to connect to the site's PLC Calibration: A calibration of the burners will take place at MCAAP, Oklahoma after government install.Complete natural gas burner assembly as described below. The burner fuel and air inlets shall be pre-plumbed assemblies with necessary fittings for operation. Associated fuel trains and blowers will be included for each burner assembly, as well as local control panels. A calibration of the burners will be provided by the vendor after the government has completed install. ThermJet 0500 Model Burner (Retort Burner System PRJ101029534 Eclipse - no substitution) •5,000,000 Btu/hr •Ambient temperature, no preheat •High velocity outlet•Alloy tube combustor•Natural gas fuel•UV scanner adapter Each burner will have an associated compatible blower and air manifold assembly included. •Blowers will include associated silencer/filter •Pre-piped air manifold assembly includes: properly sized nipple flange; modulating butterfly valve with 4-20mA I/O; and associated purge switch, combustion switch, pressure gauge, and cock valve. Each burner above will have its own skidded fuel/valve train. •1.5 in NPT Main•NEMA 4•Siemens SSOVs•Pressure Switches•Junction Box •Skid orientation to be confirmed with Government•Blowers will have associated silencer/filters Each burner will have a gas burner manifold assembly to include the associated: •Ratio Regulator•Limiting Gas Valve•Flex Nipple/Union Provide NEMA Type 4 control panel for each burner. Does not require a PID controller, as that will be handled through PLC. Items included for each burner assembly: •UV Scanner •Terminal Transformer •Ignition Transformer • Wire, 16 AWG Ignition, High Temp •4-20 mA outputs on controls, to connect to the site's PLC Calibration: A calibration of the burners will take place at MCAAP, Oklahoma after government install.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/994e09901db913f624c567f0c878d292)
 
Place of Performance
Address: McAlister, Oklahoma, United States
 
Record
SN04118314-W 20160518/160516234730-994e09901db913f624c567f0c878d292 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.