Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 10, 2016 FBO #5313
MODIFICATION

Y -- Construct New Squadroon Operations Facility

Notice Date
6/8/2016
 
Notice Type
Modification/Amendment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Army, National Guard Bureau, USPFO for Alabama, PO Box 3715, Montgomery, Alabama, 36109-0715, United States
 
ZIP Code
36109-0715
 
Solicitation Number
W912JA-16-R-0007
 
Point of Contact
Ronald W Danford, Phone: 3342717358, Stephen Shanks, Phone: 3343947529
 
E-Mail Address
ronald.w.danford.mil@mail.mil, stephen.a.shanks2.mil@mail.mil
(ronald.w.danford.mil@mail.mil, stephen.a.shanks2.mil@mail.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
NOTICE OF "ON HOLD " STATUS. This modification gives notice that the solicitation is 'on hold" until futher notice. Amendment of the solicitation and Attachment to specifications is required and pending completion. The scheduled site visit for 17 June 2016 is cancelled and will be rescheduled once all required action is completed and status change is announced on this site through modification announcement. This is a pre-solicitation notice synopsizing an upcoming RFP solicitation to satisfy the requirements of FAR 5.201 and 5.203. The Contracting Officer (KO) will not be able to answer any questions pertaining to this notice. Questions will only be answered that are received by Request for Information (RFI) after the solicitation and drawings have been posted to Federal Business Opportunities Website. The KO will not maintain a bidder's mailing list. All interested parties should register via www.fbo.gov interested vendors list. Do not contact the KO for General Contractor Information. It is the responsibility of the bidder to monitor and download amendments from FBO which may be issued to this solicitation. On or about 25 MAY 2016. the United States Property and Fiscal Office for Alabama, on behalf of the 187th Fighter Wing, Alabama Air National Guard, Montgomery Alabama intends to issue a Request for Proposal for construction contractor services for construction of new Squadron Operations Facility Project FAKZ 059173 for award of a single, firm-fixed-price contract for services, non-personal, to provide all plant, labor, transportation, materials, facilities, tools, equipment, appliances and supervision necessary to perform and complete the Squadron Operations Facility at 187th Fighter Wing, Montgomery Regional Airport, Montgomery, Alabama. Magnitude of the project is between $5,000,000 and $10,000,000. Construction/contract completion time is anticipated to take approximately 470 calendar days after notice to proceed to include inspection and punch list. The North American Industry Classification System (NAICS) code for this work is 236220. The small business size standard is $36.5 million average annual revenue for the previous three years. This action is being procured on a 100% Small Business Set Aside. Owner intends to occupy the Project upon Substantial Completion. The work of this project shall be completed in one phase. The project site is located adjacent to an existing aircraft tarmac which prohibits building structures or related construction activities from occurring within a set distance from an existing "red" line painted on the paved surface of the tarmac. Project includes but not limited to site-work, subgrade excavation, building foundations, structural, architectural, plumbing, mechanical, and electrical and relocation of existing utilities and mechanical systems for a new two story Squadron Operations Facility and associated vehicular parking. Contractor's bid shall include rough-ins for plumbing, mechanical, electrical, including installation and final connection of all items indicated on the drawings as owner furnished contractor installed. Work also includes delegated geotechnical investigation, foundation design, and work for relocating an existing three legged, self-supporting, communications tower. The project has been designed to achieve the LEED Certified rating as defined in the LEED Green Building Rating System for New Construction and Major Renovation, 2009 Edition. The technical specifications have been written to incorporate specific product requirements of the attempted LEED credits. However, the contractor shall be familiar with the LEED certification process/ documentation and incorporate any administrative costs required for successful documentation of LEED certification into their bid price. Contractor shall purchase Renewable Energy Certificates on behalf of the Owner. Building Systems Commissioning is required. The following systems, but not limited to, are to be commissioned: Plumbing Systems: 1. Water heaters. 2. Booster pumps. HVAC System, including: 1. Major and minor equipment items. 2. Piping systems and equipment. 3. Ductwork and accessories. 4. Terminal units. 5. Control system. 6. Variable frequency drives. Electrical Systems: 1. Power quality. 2. Emergency power systems. 3. Uninterruptible power systems. 4. Lighting controls other than manual switches. Electronic Safety and Security: 1. Security system, including doors and hardware. 2. Fire and smoke alarms. Communications: 1. Voice and data systems. 2. Public address/paging. The project contains spaces - referred to on drawings as "Secure Areas" - where Sensitive Compartmented Information and Special Access Program Information, is stored, used, processed or discussed. As part of the base bid, the contractor is responsible for engaging Advantor Systems Cooperation (which is a sole source security system) for the procurement and installation of the "Secure Area(s)" Access Controls and Security Systems per Advantor Systems Corporation's "Proposal" (the contractor must confirm owner's written approval of security systems proposal being included in contractor's base bid prior to the project bid date. Other particular items and systems specific to Johnson Controls, Monoco Fire Alarms Transmitters and Stanley Best Access Systems are brand name specific and intended for use on this project. Justifications for determination of use will be provided at later date. In preparation of new building construction, the project site-work includes, but is not limited to, demolition of various types of existing buildings and associated utilities; demolition of various types of existing underground and overhead site utilities; demolition of existing concrete pavement of curb and gutter, vehicular access and sidewalks, asphalt pavement of vehicular driveways and parking; demolition of various types of existing vegetation; and demolition of existing perimeter security fencing. Accepted final project shall be in accordance with final contract documents, applicable plans and specifications. Place of performance is 187th Fighter Wing, Montgomery Regional Airport, Montgomery, Alabama. Options listed below are as follows: Option No. 1 - (Deductive) Demountable Partitions: Option No. 2 (Additive): Expansion to Existing Airplane Apron/Tarmac: Option No. 3 (Additive): Geothermal Piping for Water Source Heat Pumps: Option No.4 (Additive): Fixed Seating and Raised Flooring: Option No.5 (Additive): Hard Tile Floor Patterns and Interior Wood, Hard Tile, Plastic Laminate and Acoustical Wall Treatments: Option No.6 (Additive): Under Slab Vapor Barrier: The following regulations are applicable to this project (including but not limited to the following): 1. All applicable national, state, and local codes. 2. The American Disabilities Act. 3. OSHA. 4. International Building Code (IBC) 2006 Edition 5. United Facilities Code (UFC) 6. All Applicable portions of the US Code of Federal Regulations, 7. Air National Guard ANG ETL 01-1-1 - Air National Guard Design Policy and all applicable technical letters. Other Regulatory agencies: 1. Alabama State Fire Marshall. 2. City of Montgomery - all applicable departments. 3. Dannelly Airfield Fire Department. 4. Department of Justice 5. 28 CFR 35 - Department of Justice accessibility regulations relating to State and local governments; current edition. 6. 28 CFR 36 - Department of Justice accessibility regulations relating to public accommodations; current edition. 7.36 CFR 1191 - Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines; current edition. 8. FED-STD-795 - Uniform Federal Accessibility Standards; 1988. 9. 29 CFR 1910 - Occupational Safety and Health Standards; current edition; as a work place. 10. ICC (IFC) - ICC International Fire Code, 2012. 11. NFPA 101 - Life Safety Code, 2012. 12. ICC (IBC) - ICC International Building Code, 2012. 13. ICC (IPC) - ICC International Plumbing Code, 2012. 14. ICC (IMC) - ICC International Mechanical Code, 2012. 15. ICC (IFGC) - ICC International Fuel Gas Code, 2012. 16. ICC (IEC) - ICC International Electrical Code, 2012. 17 ICC (IECC) - ICC International Energy Conservation Code, 2012. 18. Unified Facilities Criteria (UFC): 1. UFC 1-200-01: General Building Requirements. 2. UFC 3-310-01: Design: Structural Load Data. 3. UFC 4-010-01: DoD Minimum Antiterrorism Standards for Buildings. There will be a pre-bid conference/site investigation held for this project and for all prospective bidders. The tentative date for the pre-bid conference is on-or-about 8 June 2016 10:00 a.m. local time at the 187th Fighter Wing Base Civil Engineer Office. Interested contractors are encouraged to attend and shall be required to register with MSGT Stephen Shanks by 1500 hrs. 3 June 2016 and provide their given name (no nicknames), the project name, name of the company that they represent, and a state driver's license number. Contractors must provide a list with the names of the persons to be attending the site visit on Company Letterhead and email it to MSGT Shanks at stephen.a.shanks2.mil@mail.mil. Attendees will be required to provide a valid driver's license, proof of insurance, and vehicle registration to gain access to the installation. A site location visit will follow the pre-bid conference. Due to Base Security requirements and limited field staff available for construction contractor site visits, this scheduled site visit will be the only one offered. Individual requests for site visits will not be granted. All questions for the pre-bid conference must be submitted by 3 June 2016 via e-mail to ronald.w.danford.mil@mail.mil and stephen.a.shanks2.mil@mail.mil. The solicitation closing date is scheduled for on-or- about date 30 June 2016 Actual dates and times will be identified in the solicitation. The source selection process will be conducted in accordance with FAR 15.3 and DFARS Part 215.3, source selection procedures. The evaluation factors are Technical Capability, Past/Present Performance and Price. Government intends to award without discussions. The solicitation, associated information, and the plans/specifications will only be available from the Federal Business Opportunities (FedBizOps) website on-line at https://www.fbo.gov FedBizOps is a web-based dissemination tool designed to safeguard acquisition-related information for all Federal agencies. Interested bidders/offeror must register with FedBizOps before accessing the system. FedBizOps registration requires the following information: 1) System for Award Management (SAM), 2) DUNS Number and CAGE Code, 3) Telephone Number, 4) Email address. Registration instructions can be found on the FedBizOps website at https://www.fbo.gov/downloads/FBO_Vendor_Guide.pdf. NOTE: Contractors who do not already have a MPIN are advised that the normal processing is 7 to 15 business days to obtain a MPIN password that will give them access to the plans and specifications, which are located in the controlled access location on FBO. See video in vendor guide at 3.3 on advanced functions for other information https://www.fbo.gov/demos/vendor-advanced/. Bidders/offeror who have registered with FedBizOps must access the data for this solicitation with their MPIN. Bidders/Offerors cannot log into the FedBizOps home page and search for data. DISCLAIMER: The official plans and specification are located on the official government web page and the Government is not liable for information furnished by any other source. Amendments, if/when issued will be posted to the FedBizOpps page for electronic downloading. This will normally be the only method of distributing amendments prior to closing; therefore, it is the offeror responsibility to check the website periodically for any amendments to the solicitation. Websites are occasionally inaccessible due to various reasons. The Government is not responsible for any loss of Internet connectivity or for an offeror‘s inability to access the documents posted on the referenced web pages. The solicitation will not be a competitive Invitation for Bid (IFB) and there will not be a formal, public opening.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA01/W912JA-16-R-0007/listing.html)
 
Place of Performance
Address: 187th Fighter Wing, 5187 Selma Highway, Montgomery, Alabama, 36109-4824, United States
Zip Code: 36109-4824
 
Record
SN04143440-W 20160610/160608235006-79bdd8deacb2dacc3b0e246ab539bef8 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.