SOLICITATION NOTICE
Z -- CSC-16703 Security Enhancements FY16 - Attachment #4 - Solicitation - Attachment #5
- Notice Date
- 6/15/2016
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 237310
— Highway, Street, and Bridge Construction
- Contracting Office
- Defense Logistics Agency, DLA Acquisition Locations, DLA Land and Maritime, P O Box 3990, Columbus, Ohio, 43218-3990, United States
- ZIP Code
- 43218-3990
- Solicitation Number
- SP4702-16-R-0015
- Archive Date
- 8/3/2016
- Point of Contact
- Barbara Ann Bocsy, Phone: 6146923650
- E-Mail Address
-
barbara.bocsy@dla.mil
(barbara.bocsy@dla.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- Excavation Permit Solicitation SP470216R0015 Engineering Form 4025 The Defense Logistics Agency, Defense Supply Center has a requirement for Security Enhancements located at the Defense Supply Center Columbus, Ohio. This procurement is issued as a 100% small business set aside. The NAICS for this requirement is 237310. The Small Business size standard for this requirement is $36,500,000.00. The award will be a firm fixed contract. Award will be based on the lowest evaluated price of the technically acceptable proposal meeting all of the solicitation requirements from responsible offerors with acceptable past performance. There will be one award made for this project. Award may be made without discussions. The following summary is for the purpose of general information and is not intended to include or describe every feature or item or to define the scope of work. It is expected that prospective contractors will attend the site visit, review solicitation documents, and thoroughly familiarize themselves with the project prior to submitting a proposal. One preproposal conference/site visit is scheduled for this project and is scheduled for 10:00 AM local time on 28 June 2016. ATTENDANCE AT THE SITE VISIT IS A MANDATORY REQUIREMENT EACH OFFERER SUBMITTING A PROPOSAL SHALL HAVE A REPRESENTATIVE AT THE SITE VISIT. PROPOSALS RECEIVED FROM ANY CONTRACTOR THAT DID NOT ATTEND THE SITE VISIT WILL NOT BE EVALUATED FOR AWARD. All individuals wishing to attend will be required to request Center access no later than 24 hours prior to the site visit date. Those individuals wishing to attend must provide their name and corporate affiliation to barbara.bocsy@dla.mil by email. The Defense Supply Center is a secure facility and individuals who do not preregister will not be granted access. Registered participants can not bring unregistered personnel on center with them. Individuals will need to enter the Center through the Visitor Processing Center at 401 North Yearling Road and valid federal or state issued photo identification will be required. PROJECT INFORMATION: The Request for Proposals will solicit for a single award firm fixed priced contract for work to be performed at the Defense Supply Center Columbus located in Columbus, OH. SCOPE: This section of the specifications covers the general requirements to enhancements of the DSCC Security Systems at Defense Supply Center Columbus, Ohio. The contractor shall furnish all plant, labor, equipment, materials, supplies, testing and supervision required in performing all operations in conjunction with this project in strict accordance with the specifications, contract drawing No. 6-287 (15 sheets), complete and subject to the terms and provisions of this contract. Contractor shall perform the following work to complete this project: Replace Bldgs. 20 & 21 drop off/ pick-up lanes hydraulic & manual bollards with RSS-4000 Electric Retractable Bollards. Provide Wrong Way Detection Systems at the James Road Gate. Correct Drainage Deficiencies at ID Check Canopy and Visitor Control Center (VCC) Bldg. 61. Construct Wind Screen on West Side of ID Check Canopy at Main Gate. Construct Wind Screens to Search Area Canopy at Main Gate. Installation of pipe bollard as vehicle barriers at north of ID Check Booth # 5 at main gate Replace existing electro-mechanical vehicle control drop beam barriers at the following (6) locations by installing RSS-3000 Electric Drop Beams: - 18 th Blvd. at East of Bldg.20 - 16 th Blvd. near A Street - 16 th Blvd. near Roosevelt Lane - Jackson Blvd. near Roosevelt Lane - Jackson Blvd. near Pershing Avenue - 11 th Blvd. near Roosevelt Lane CONTRACTOR QUALIFICATIONS: This project requires the use of specialized contractors capabilities and experienced staffing. The general contractor and all key sub-contractors shall have a minimum three (3) years' experience in all facets of construction projects under the assigned NAICS code. Offerors must provide information regarding their Technical Construction Capabilities and Technical Qualifications of Proposed Staffing, to include the individuals who will be responsible for Project Management, Quality Control, and Safety Compliance. A) Past Performance: Offeror shall provide past procurement contracts and references for projects satisfactorily completed within the last three (3) years of similar size and scope. A minimum of 3and a maximum of 5 past contracts. B) Technical Construction Capability: A written technical construction management plan shall be submitted by the offeror to demonstrate their understanding and capabilities of completing all work in accordance with the Statement of Work and project drawings. The plan must identify all work that can be accomplished with in-house resources and demonstrate that they are capable of obtaining any project requirements that cannot be self-performed. The technical construction management plan must identify how the offeror will directly superintend the work, perform project and quality control management, comply with safety and environmental regulations; any project requirements that cannot be self-performed must be identified (e.g. subcontractors list and manufacturers of key material components for the project) The offeror shall provide this information with their company proposal submission. C) Technical Qualifications of Proposed Staffing: Written qualification statement for the individual who will be responsible for project management of the project. o Qualifications The Project Manager must have a minimum of 5 years experience as a Project Manager or Superintendent on projects of similar size and complexity. • Written qualifications statement for the individual who will be responsible for quality control in accordance with General Requirements Section 01 45 0010 20 Paragraph 1.6.1. o Qualifications  An individual with a minimum of 5 years combined experience as a superintendent, inspector, QC Manager, project manager, or construction manager on similar size and type construction contracts which included the major trades that are part of this contract. The individual must be familiar with the requirements of the EM 385-1-1 and have experience in the areas of hazard identification and safety compliance. o Construction Quality Management Training  In addition to the above experience and education requirements, the QC Manager shall have completed the course Construction Quality Management for Contractors and will have a current certificate. • Written qualifications statement for the individual who will be responsible for safety in accordance with FAR 52.236-13 Accident Prevention (Nov 1991). Accident Prevention includes compliance with the standards issued by the Secretary of Labor at 29 CFR Part 1926 and 29 CFR Part 1910; and compliance with all pertinent provisions of the latest version of U.S. Army Corps of Engineers Safety and Health Requirements Manual, EM 385-1-1, in effect on the date of the solicitation. This individual will be designated as the Site Safety and Health Officer (SSHO). o Qualifications and Training  The SSHO(s), as a minimum, must have completed the 30-hour OSHA Construction safety class or as an equivalent, 30 hours of formal construction safety and health training covering the subjects of the OSHA 30-hour course (see Appendix A, paragraph 4.b) applicable to the work to be performed and given by qualified instructors. > The SSHO is also required to have five (5) years of construction industry safety experience or three (3) years if he possesses a Certified Safety Professional (CSP) or safety and health degree. The written qualifications statement shall be certified and signed by a principle of the offeror. Offerors shall submit a resume of each key individual. This will be evaluated to determine if they have the appropriate technical training, certifications, and previous construction experience to meet the technical requirements of a project of this nature. If any of the submitted individuals will perform more than one of the listed functions, this is acceptable as long as the submitted documentation identifies any and all functions the given individual will be performing Details of workmanship shall be in accordance with the highest standards and best practices of the respective trade as recognized by respective contractor's association. Only qualified tradesmen or mechanics shall be assigned to do the work required by this contract. At no time shall the work be accomplished by apprentices or laborers without the supervision of a journeyman or higher level supervision. Contractor personnel will not require a secret clearance. The contract will be required by law to pay prevailing Service Contract Act wage rates for all work awarded under the contract. The Defense Supply Center Columbus is located in Franklin County, Ohio. PERIOD OF PERFORMANCE: All work associated with the performance of this project must be completed within 270 calendar days after issuance of the Notice to Proceed. Questions concerning this requirement must be submitted no later than 4:00 PM local time on 07 July 2016. The solicitation will close at 1:00 PM (Eastern) on 19 July, 2016.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DLA/J3/DSCC/SP4702-16-R-0015/listing.html)
- Place of Performance
- Address: Defense Supply Center Columbus, 3990 East Broad Street, Columbus, Ohio, 43213, United States
- Zip Code: 43213
- Zip Code: 43213
- Record
- SN04150870-W 20160617/160615234812-97bb94ce4f2654d36e4603ca8d247ac2 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |