SOLICITATION NOTICE

J -- Compressed Air/Vacuum Maintenance - Solicitation

Notice Date
6/16/2016
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
Department of the Army, Army Contracting Command, MICC, MICC - West Point, 681 Hardee Place, West Point, New York, 10996-1514, United States
 
ZIP Code
10996-1514
 
Solicitation Number
W911SD-16-T-0255
 
Archive Date
7/10/2016
 
Point of Contact
Robert L. Pizzano, Phone: 8459384761
 
E-Mail Address
robert.l.pizzano.civ@mail.mil
(robert.l.pizzano.civ@mail.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Solicitation Documents House Air/Vacuum Performance Work Statement USMA Bartlett Hall Science Center has compressed air and vacuum distributed throughout building. These services emanate from two central facilities. One is in the subbasement; the other is on the roof. Preventive maintenance is required on both systems. The equipment in the subbasement consists of:  Quadraplex Hitachi model 110U-8.5CG2H air compressors with Weg 15HP motors and two dual-tower dryers (Trident Dryspell with DS 31-200 controllers).  Triplex Busch model RC0400.B033.1037 vacuum pumps with Baldor 15HP motors.  Both have control systems integrated by Amico Air and Vacuum Systems. The equipment on the roof consists of:  Triplex Powerex OBS150700E air compressors with Baldor motors and a single dual tower dryer.  Duplex Busch model RC0400.B033.1035 vacuum pumps with Baldor 15HP motors.  Both have control systems integrated by Engineered Medical Systems and Equipment. The preventive maintenance being sought will be performed quarterly and annually. A service report will be supplied after each maintenance visit Quarterly Maintenance - Compressed Air  Inspect drive belts - adjust as necessary  Inspect safety relief valves for proper operation  Inspect and clean intake air filters  Test function of automatic tank drain  Inspect unloader solenoids  Check for leaks  Inspect motors - perform amperage draw test  Inspect air dryers  Inspect air treatment filters  Inspect pressure regulators  Inspect dew point monitors - verify proper operation  Test lead / lag function  Inspect all electrical controls for proper operation - tighten connections if required  Verify function of all local alarms  Inspect for loose hardware - tighten if required  Check hour meters and record readings  Clean all equipment and surrounding areas Quarterly Maintenance - Vacuum  Change oil and oil filters  Inspect condition of separator elements as per readings on gauges  Inspect inlet filter elements - clean if required  Test check valves for proper operation  Check for oil leaks  Check all electrical components for proper operation - tighten connections if required  Check hour meters and record readings  Inspect condition of drive couplings  Clean all equipment and surrounding areas Annual Maintenance - Compressed Air  All elements comprising quarterly maintenance service.  Change inlet filters in medical air compressors.  Change air treatment filter elements.  Lubricate motor bearings. Annual Maintenance - Vacuum  All elements comprising quarterly maintenance service.  Replace inlet filters.  Replace exhaust separators.  Lubricate motor bearings. All oil and parts and other consumables required to perform all of the above mentioned services shall be provided by the contractor and included in the cost of this service agreement. Oil and parts will be compliant with manufactures specifications. All used oil, filters, etc. will be removed from the facility and disposed of properly. If any deficiencies or materials not covered under the service agreement are found to be required, a written estimate will be provided and no work shall be performed without prior consent.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/046e55788fc119ccb2dff31c3bf51821)
 
Place of Performance
Address: United States Military Academy @ West Point, NY, West Point, New York, 10996, United States
Zip Code: 10996
 
Record
SN04153083-W 20160618/160616235427-046e55788fc119ccb2dff31c3bf51821 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.