Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 24, 2016 FBO #5327
SOLICITATION NOTICE

Y -- Albeni Falls Dam 115 kV Transformer Motor Operated Disconnect (MOD) Replacement, Oldtown, Idaho

Notice Date
6/22/2016
 
Notice Type
Presolicitation
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Seattle, Attn: CENWS-CT, PO Box 3755, Seattle, Washington, 98124-3755, United States
 
ZIP Code
98124-3755
 
Solicitation Number
W912DW-16-B-0012
 
Archive Date
8/23/2016
 
Point of Contact
Monique Paano, Phone: 206-764-6084
 
E-Mail Address
monique.a.paano@usace.army.mil
(monique.a.paano@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
POINT-OF-CONTACT: The point-of-contact for administrative or contractual questions is Contract Specialist Monique Paano at email: Monique.A.Paano@usace.army.mil. Please no phone calls. All questions must be submitted in writing to the above point-of-contact. FOR INFORMATION ONLY: This Synopsis/Pre-Solicitation Notice is ONLY A NOTIFICATION that a solicitation is anticipated and forthcoming. All questions regarding this Synopsis/Pre-Solicitation should be submitted in writing via email to Ms. Paano at the email indicated above. Description of Work (physical characteristics): a) Disconnect Switch - The existing 135 kV disconnect switches, including the manually operated 3-pole grounding switches, will be replaced with 170 kV rated switches. The existing steel lattice supporting structure will remain and be re-used. The contractor will be responsible for having the switch manufacturer develop and provide whatever mounting adaptation is required to install the new switch on the existing structure. b) Switch Operators - The existing electric-mechanical line switch operators will be replaced with an electric-mechanical Operator. The operator will feature a manual crank for hand operation in the event of loss of power. The manually operated grounding switch is used to provide a safety ground for personnel performing maintenance on the disconnect switch after the 115 kV line has been de-energized and will be operated independently of the line disconnect. The interlocking of the main line disconnect switches and grounding switches will be accomplished both mechanically and electrically. Position indication of both the disconnect switches and the grounding switch are to be provided locally at the local control panel and remotely to the control room. c) Controls and Power Source - A 125 VDC power source will be provided to match the existing configuration of disconnect switches. It will be provided from the CE Panel Boards. 120 VAC will be provided to power the cabinet heaters. The control cables from the control room to the disconnect switch control panels are to be replaced. The heater power feeders are to be an optional replacement item if needed. The magnitude of construction is estimated to be between $250,000 and $500,000. The resulting contract will be firm-fixed-price. Solicitation number W912DW-16-B-0012 will be posted to the Federal Business Opportunities (FBO) website, www.fbo.gov, on or about 7 July 2016. The solicitation will be an Invitation for Bids. Bids will be due no sooner than 30 calendar days after actual solicitation issuance date. See the solicitation for details about proposal submission. The NAICS code for this procurement is 238210, Electrical Contractors and Other Wiring Installation Contractors, and the associated small business size standard is $15,000,000 in average annual receipts. The solicitation will be issued as Unrestricted. A site visit will be offered within approximately 2 weeks after the solicitation is made available via FBO. Refer to the solicitation for details regarding the site visit. The solicitation documents for this requirement will be issued in electronic format only and will be made available online via the FBO website at www.fbo.gov under the subject solicitation number. NO CD's OR HARD COPIES WILL BE AVAILABLE. Offerors are responsible for checking for any update(s) to the Notice/Solicitation. The Government is not responsible for any loss of Internet connectivity or for an offeror's inability to access the document(s) posted at the referenced website. To obtain automatic notifications of updates to this notice, you must log in to www.fbo.gov and add the solicitation to your Watchlist. If you would like to list your firm so others can see you are an interested vendor, you must click the Add Me To Interested Vendors button in the listing for this solicitation on www.fbo.gov. The FBO Response Date listed elsewhere in this synopsis is for FBO archive purposes only. It may have no relationship to the actual solicitation due date. The solicitation due date and time will be contained in the solicitation and any solicitation amendments that are issued. IMPORTANT NOTICE: All contractors proposing on Department of Defense (DoD) solicitations must be registered in the System for Award Management (SAM) database prior to award of a contract. The purpose of this database is to provide basic business information and capabilities to the Government. The SAM website can be accessed at www.sam.gov. Contractors are encouraged to register as soon as possible. All new contracts can be made ONLY to contractors who are registered in SAM. This requirement applies to all DoD contract awards.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA67/W912DW-16-B-0012/listing.html)
 
Place of Performance
Address: Albeni Falls Dam, 2376 East Highway 2, Oldtown, Idaho, 83822-9243, United States
Zip Code: 83822-9243
 
Record
SN04157657-W 20160624/160622234153-6274136cd9b2a7625bf8f97cb8241d29 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |