SOLICITATION NOTICE
Z -- McNary Levee Drainage Pump Stations – Roof and Roof Hatches
- Notice Date
- 6/28/2016
- Notice Type
- Presolicitation
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of the Army, U.S. Army Corps of Engineers, USACE District, Walla Walla, Attn: CENWW-CT, 201 North 3rd Avenue, Walla Walla, Washington, 99362-1876, United States
- ZIP Code
- 99362-1876
- Solicitation Number
- W912EF-16-B-0004
- Archive Date
- 6/28/2017
- Point of Contact
- Cristina A Vega, Phone: 5095277231
- E-Mail Address
-
cristina.a.vega@usace.army.mil
(cristina.a.vega@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- Construction Project: McNary Levee Drainage Pump Stations - Roof and Roof Hatches. This will be a firm-fixed-price construction contract located at several pumping stations on the levee system upstream of McNary Dam (Umatilla County, Oregon). Estimated construction magnitude is between $500,000 and $1,000,000; and 100% performance and payment bonds will be required. Summary Scope of Work: This upgrade project is for 11 of the McNary Levee Drainage Pumping Station plants located in Tri-Cities, Washington. The levee drainage pumping plants are located in Finley, Kennewick, Pasco, and Richland, WA. These drainage pumping plants are used to remove drain and storm water from the culverts and ditches located along these levees. These pumping plants utilize pumps to pump water from their wet wells, received by ditches and ponds, to the Columbia River to avoid pooling up of water and flooding of local businesses and homes in Finley, Kennewick, Pasco, and Richland. This project will include cleaning off the old roof (rocks, dirt), demolishing old roofing material, installing new roofing materials, providing new roof equipment hatches, modifications to the roof structure to allow for roof equipment hatch installation and relocating interior electrical lighting for those plant with new roof hatches. This effort is to make pumps and motors more accessible, and other repairs easier, safer, and more efficient. The following are needed at each station: Drainage Pump Station 2C (Richland, WA) • Replace existing roll-up metal service door • Repair Brick masonry (Fix crack in the building structure and repair deteriorated parapet walls) • Replace existing Built-Up-Roofing (BUR) with new Polymethyl Methacrylate (PMMA) roofing and tapered insulation Drainage Pump Station 4A (Richland, WA) • Structurally modify steel and concrete roof deck to support new roof equipment hatches • Fabricate custom roof equipment hatches with air vents and install above each pump • Replace existing BUR with new PMMA roofing • Replace ceiling electrical lighting to surface-wall mounted conduit and electrical lighting Pumping Station 12-1 (Pasco, WA) • Structurally modify steel and concrete roof deck to support new roof equipment hatches • Fabricate custom roof equipment hatches with air vents and install above each pump • Replace existing BUR with new PMMA roofing • Replace ceiling electrical lighting to surface-wall mounted conduit and electrical lighting Pumping Station 12-1A (Pasco, WA) • Replace existing Fluid-Applied Roofing with new PMMA roofing Pumping Station 12-2 (Pasco, WA) • Replace existing Polyurethane Foam (PUF) Roofing with new PMMA roofing Pumping Station 5D (Kennewick, WA) • Structurally modify steel and concrete roof deck to support new roof equipment hatches • Fabricate custom roof equipment hatches with air vents and install above each pump • Replace existing BUR with new PMMA roofing • Replace ceiling electrical lighting to surface-wall mounted conduit and electrical lighting Pumping Station 6B (Kennewick, WA) • Fabricate custom roof equipment hatches and install above each pump • Replace existing BUR with new PMMA roofing Pumping Station 15-C (Finley, WA) • Structurally modify steel and concrete roof deck to support new roof equipment hatches • Fabricate custom roof equipment hatches with air vents and install above each pump • Replace existing BUR with new PMMA roofing • Replace ceiling electrical lighting to surface-wall mounted conduit and electrical lighting Pumping Station 15-D (Finley, WA) • Replace existing PUF Roofing with new PMMA roofing Pumping Station 15-E (Finley, WA) • Structurally modify steel and concrete roof deck to support new roof equipment hatches • Fabricate custom roof equipment hatches with air vents and install above each pump • Replace existing BUR with new PMMA roofing • Replace ceiling electrical lighting to surface-wall mounted conduit and electrical lighting Pumping Station 15-E1 (Finley, WA) • Replace existing BUR with new PMMA roofing • Fabricate custom roof equipment hatches with air vents and install above each pump Solicitation Number W912EF-16-B-0004 will be posted to the FBO website on or about July 12, 2016. The solicitation is an Invitation for Bids. The bid opening date will be contained in the solicitation. Important Note: The FedBizOpps Response Date listed elsewhere in this synopsis is for FedBizOpps archive purposes only. It does not necessarily reflect the actual proposal closing date. The proposal closing date will be contained in the solicitation and any solicitation amendments that may be issued. A site visit will be offered approximately 2 weeks after the solicitation is made available to bidders. See solicitation for details about the site visit. ACCESS FOR FOREIGN NATIONALS: Security clearance for foreign nationals to attend a site visit requires approximately 4 weeks; therefore, clearance should be requested immediately. To request clearance, please submit the names of all foreign nationals proposed for site visit attendance, along with documentation to verify that he/she was legally admitted into the United States and has authority to work and/or go to school in the US. Such documentation may include a US passport, Certificate of US citizenship (INS Form N-560 or N-561), Certificate of Naturalization (INS Form N-550 or N-570), foreign passport with I-551 stamp or attached INS Form I-94 indicating employment authorization, Alien Registration Receipt Card with photograph (INS Form I-151 or I-551), Temporary Resident Card (INS Form I-688), Employment Authorization Card (INS Form I-688A), Reentry Permit (INS Form I-327), Refugee Travel Document (INS Form I-571), Employment Authorization Document issued by the INS which contains a photograph (INS Form I-688B). Send this information by email to Cristina.a.Vega@usace.army.mil. Foreign nationals must have received clearance prior to being granted access to the project site. Solicitation is unrestricted and open to both large and small business. NAICS code for this project is 236220, and the small business size standard is $36,500,000 average annual receipts. When available, the solicitation documents for this project will be available via FedBizOpps.gov https://www.fbo.gov NO CD's OR HARD COPIES WILL BE AVAILABLE. Bidders are responsible for checking the referenced page for any update(s) to the Notice. The Government is not responsible for any loss of Internet connectivity or for an offeror's inability to access the document posted at the referenced website. To obtain automatic notifications of updates to this solicitation, you MUST log in to FedBizOpps.gov and add the solicitation to your Watchlist. If you would like to list your firm so others can see you are an interested vendor, you must click the "Add Me To Interested Vendors" button in the listing for this solicitation on FedBizOpps.gov.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA68/W912EF-16-B-0004/listing.html)
- Place of Performance
- Address: McNary Dam Levees, Multiple Locations: Kennewick, Finley, Pasco and Richland, Washington, United States
- Record
- SN04164894-W 20160630/160628235152-f41b1a19bef85eb240ddb9d6d6c17450 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |