FBO DAILY - FEDBIZOPPS ISSUE OF JULY 09, 2016 FBO #5342
MODIFICATION

66 -- OPTICAL SPECTRUM ANALYZER

Notice Date
7/7/2016
 
Notice Type
Modification/Amendment
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
53560 Hull Street Bldg A33 Rm 1602W, San Diego CA 92152-5001
 
ZIP Code
92152-5001
 
Solicitation Number
N66001-16-T-8047
 
Response Due
7/12/2016
 
Archive Date
8/11/2016
 
Point of Contact
Point of Contact - Rebeca M Holguin, Contract Specialist, 619-553-0901; Dorothy J Powell, Contracting Officer, 619-553-4455
 
E-Mail Address
Contract Specialist
(rebeca.holguin@navy.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
This is a SSC Pacific combined synopsis/solicitation for commercial items prepared in accordance with Federal Acquisition Regulation (FAR) Part 12, Acquisition of Commercial Items and FAR Part 13, Simplified Acquisition Procedures. This announcement constitutes the only solicitation. Competitive quotes are being requested under N66001-16-T-8047 for Optical Spectrum Analyzer. This requirement is set-aside for small businesses, NAICS code is 334515 and the size standard is 750 Employees. CLIN 0001 OPTICAL SPECTRUM ANALYZER 1 Each See Salient Characteristics attached If a specification cannot be met, please suggest best alternative. Basis for award: The government anticipates awarding a firm-fixed price purchase order and it will be based on the lowest technically acceptable quote. This RFQ closes on July 12, 2016 at 11:00 AM, Pacific Daylight Time (PDT). Quotes must be uploaded on the SPAWAR e-commerce website at https://e- commerce.sscno.nmci.navy.mil under SSC Pacific/Simplified Acquisitions/N66001-16-T-8047 All questions must be uploaded on the SPAWAR e-commerce website at https://e- commerce.sscno.nmci.navy.mil under SSC Pacific/Simplified Acquisitions/ N66001-16-T-8047 PLEASE NOTE: 1. Quotes and questions emailed directly to my email inbox will NOT be considered. 2. If you need assistance with the website you MUST contact the SPAWAR Helpdesk at 858-537-0644 or email at paperless.spawar@navy.mil 3. Please include the following: a. CAGE Code b. DUNS c. Business Size 4. Preferred method of shipment: FOB Destination. (Please include shipping as separate line item if other than FOB Destination) Ship to Address: SPAWAR Systems Center Pacific Receiving Officer 4297 Pacific Highway, Bldg OT7 San Diego, CA 92110-5000 The point of contact for this solicitation is Rebeca Holguin at rebeca.holguin@navy.mil. Please include RFQ N66001-16-T-8047 on all inquiries. All responding vendors must have a completed registration in the System for Award Management (SAM) program prior to award of contract. Information to register in SAM can be found at: https://www.sam.gov/portal/public/SAM/. Complete SAM registration means a registered DUNS and CAGE Code numbers. This solicitation document incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-88 (05/16/2016) and Defense Federal Acquisition Regulation Supplement (DFARS), May 10, 2016. It is the responsibility of the contractor to be familiar with the applicable clauses and provisions. The clauses can be accessed in full text at www.farsite.hill.af.mil. FAR Clauses 52.204-2 Security Requirements 252.204-7000 Disclosure Of Information 252.204-7008 (Dev) Compliance with Safeguarding Covered Defense Information Controls 252.204-7012 Safeguarding Covered Defense Information and Cyber Incident Reporting. FAR Clause at 52.212-1, Instructions to Offerors Commercial, and 52.212-4, Contract Terms and Conditions Commercial Items, incorporated by reference, applies to this acquisition. FAR Clause 52.212-3, Offeror Representations and Certifications -- Commercial Items and DFAR S 252.212-7000 Offeror Representations and Certifications-- Commercial Items applies to this acquisition in e-Commerce. DFARS 252.204-7000, Disclosure of Information; 252.204-7012, Safeguarding of Unclassified Controlled Technical Information; 252.203-7999, Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements; and 252.203-7998, Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements (Deviation 2015-00010) (Feb 2015) FAR 52.211-6, Brand Name or Equal (Aug 1999), 52.222-3, Convict Labor (E.O. 11755), 52.222-19, Child LaborCooperation with Authorities and Remedies (E.O. 13126), 52.222-21, Prohibition of Segregated Facilities (Feb 1999), 52.222-26, Equal Opportunity (E.O. 11246), 52.225-13, Restrictions on Certain Foreign Purchases (E.O.'s, proclamations, and statutes administered by the Office of Foreign Assets Control of the Department of the Treasury), 52.232-33, Payment by Electronic Funds Transfer System for Award Management (31 U.S.C. 3332), FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive OrdersCommercial Items (Deviation 2013- 00019) (July 2014), FAR 52.222-36, Affirmative Action for Workers with Disabilities, 252.209-7998, Representation Regarding Conviction of a Felony Criminal Violation under any Federal or State Law. Electronic and Information Technology (EIT) accessibility Standards developed by the U.S. Access Board (36 CFR Part 1194) and incorporated in the FAR (Part 39.2). The Technical Standards and their reference numbers are as follows: 1194.21 Software applications and operating systems. 1194.22 Web-based intranet and internet information and applications. 1194.23 Telecommunications products. 1194.24 Video and multimedia products. 1194.25 Self-contained, closed products. 1194.26 Desktop and portable computers. SALIENT CHARACTERISTICS Optical spectrum analyzer shall have wavelength range: 600 to 1700nm Optical spectrum analyzer shall have high wavelength accuracy: 0.01nm Optical spectrum analyzer shall have high wavelength resolution: 0.02nm Optical spectrum analyzer shall have wide dynamic range: 78dB typ. Optical spectrum analyzer shall have wide level range: +20 to -90dBm Optical spectrum analyzer shall be capable of fast measurement: 0.2 sec. (100nm span) Optical spectrum analyzer shall be applicable to single-mode and multimode fibers Optical spectrum analyzer shall integrate stray-light suppression capability of 80db. Optical spectrum analyzer shall be capable of sharp filter edge with performance of 58dB. Optical spectrum analyzer shall be capable of wide Level Range: +20DBm to -90dBm Optical spectrum analyzer shall have standard fiber optic inputs /PC and /APC. Optical spectrum analyzer shall be capable of free-space input without physical contact. Optical spectrum analyzer shall integrate level correction function to correct the level offset caused by an insertion loss of angled PC connector. Optical spectrum analyzer shall have software interface with trace Zooming to change display conditions, such as center wavelength and span, by clicking and dragging the mouse and enlarge your area of interest instantly and move it at will. Optical spectrum analyzer shall have mouse & keyboard Operation with Front panel operation proven intuitive and easy to use by our many of users. Even easier with a mouse. The keyboard helps enter labels and file names. Optical spectrum analyzer shall have integrated USB interfaces support large- capacity removable memory and hard disk drives. Optical spectrum analyzer shall have at least 512 MB internal memory for over 20,000 traces where seven traces can be save in one file at once. Optical spectrum analyzer shall have data logging function to record analysis results such as WDM analysis (OSNR, optical signal/noise ratio), distributed feedback laser diode (DFB-LD) analysis, and multi-peak measurements at up to 10,000 points per channel with time stamps. Recorded data can be displayed in table and graphical forms. This function is useful for the long-term stability testing and temperature cycle testing of systems and devices. The optical spectrum of each measurement can also be stored for reviewing and troubleshooting. Optical spectrum analyzer shall have Advanced Marker function adds markers to obtain the power density and the integrated power of a designated spectrum. This new feature makes it easy to get an OSNR value of the signal, whether modulated or not, directly from its spectrum. Optical spectrum analyzer shall have Gate Sampling function facilitates the recirculating loop testing of optical transmission systems. Using an external gate signal, the AQ6370D obtains the optical spectrum of the signal which is passing through a certain loop. The advantage of this approach is its speed compared with the conventional External Trigger or Sweep Enable function. Optical spectrum analyzer shall have Resolution Calibration function is used to calibrate the noise equivalent bandwidth with an external light source. With this new feature, the measurements of power density of a broad spectrum light source will be more accurate Optical spectrum analyzer shall have capability for simultaneous multi-trace display with Calculation between traces (subtraction between traces) and Max/Min hold modes. Optical spectrum analyzer shall have built-in spectral Analysis Functions for popular applications, such as: Spectral width analysis, WDM (OSNR) analysis, WDM- NF (EDFA) analysis, DFB-LD analysis, FP-LD analysis, LED analysis, SMSR analysis, Various filter analysis, With the macro programming, multiple analyses can be combined and executed automatically. Optical spectrum analyzer shall be capable of interfacing to build a simple auto-measurement system without an external controller and easy to create test program by recording the user's actual key strokes and parameter selections. Optical spectrum analyzer shall have integrated remote interfaces including GP-IB, RS-232, and Ethernet (10/100Base-T) interfaces Optical spectrum analyzer shall be capable of SCPI compatible commands and AQ6317 Emulation Mode with the LabVIEW Driver available Optical spectrum analyzer shall capability to detect for ambient condition change due to vibration and shock to maintain high optical performance within a couple of minutes so that you can quickly start a measurement. Optical spectrum analyzer shall have Built-in wavelength reference source for the wavelength calibration and optical alignment. Optical spectrum analyzer shall have integrated Wavelength calibration function that automatically calibrates with the built-in wavelength reference or an external light source, to ensure the wavelength accuracy. Optical spectrum analyzer shall have Optical alignment function that automatically aligns the optical path in the monochromator using the built-in source to maintain high performance.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/f9a25c4a63a751dcffa67bc1c0fd6c11)
 
Record
SN04174289-W 20160709/160707235313-f9a25c4a63a751dcffa67bc1c0fd6c11 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers