Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 15, 2016 FBO #5348
DOCUMENT

59 -- Identify, label and install the NFPA 70E Arc Flash assessment label from the first Over Current Protective Device (OCPD) down to each point of the Building's electrical systems. - Attachment

Notice Date
7/13/2016
 
Notice Type
Attachment
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of Veterans Affairs;NCA Contracting Service;75 Barrett Heights Rd. Suite 309;Stafford VA 22556
 
ZIP Code
22556
 
Solicitation Number
VA78616Q0283
 
Response Due
7/29/2016
 
Archive Date
9/27/2016
 
Point of Contact
Marcellus Jernigan
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Scope of Work Marion National Cemetery VA Medical Center, 1700 East 28th Street, Marion, IN 46952 Arc Flash Hazard Analysis For the entire facility, provide all labor, materials, tools, equipment, transportation and supervision for the following items at the Marion National Cemetery, Marion, IN 1.Identify, label and install the NFPA 70E Arc Flash assessment label from the first Over Current Protective Device (OCPD) down to each point of the Building's electrical systems. 2.Label all equipment including the existing ones: Electrical equipment such as switchboards, panel boards, industrial control panels, meter socket enclosures, and motor control centers that are in other than dwelling units, and are likely to require examination, adjustment, servicing, or maintenance while energized, shall be field marked with a label containing all the following information: 1.All of the following: a.Available incident energy and the corresponding working distance b.Minimum arc rating of clothing c.Site- specific level of PPE d.The arc flash PPE category in Table 130.7( C )(15)(b) or Table 130.7( C )(15)(d) for the equipment. 2.Nominal system voltage 3.Arc flash boundary The method of calculating and data to support the information for the label shall be documented. A preliminary count of 5 electric panels and 7 disconnect switches were made for Marion National Cemetery however; a pre-bid visit by the bidder is required to get an accurate count of the electrical equipment necessitating an Arc Flash Analysis. All work must be done in accordance with applicable federal, state and local codes and regulations. Marion National Cemetery BuildingPanel BoardDisconnect Main Admin. Building 130135 Maint. Bldg/Wash Bay 3004- M11 Building 300210 Irrigation Booster Pump01 Utility pole transformers3
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANCA/VANCA/VA78616Q0283/listing.html)
 
Document(s)
Attachment
 
File Name: VA786-16-Q-0283 VA786-16-Q-0283_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2867103&FileName=VA786-16-Q-0283-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2867103&FileName=VA786-16-Q-0283-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04181867-W 20160715/160713235457-87318b34274eb25c55b57f9822d58f46 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers