Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 27, 2016 FBO #5360
SOURCES SOUGHT

43 -- Laboratory, Measuring, Observing and Testing Equipment

Notice Date
7/25/2016
 
Notice Type
Sources Sought
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
Department of Energy, SLAC National Accelerator Lab, SLAC National Accelerator Lab, 2575 Sand Hill Road, Menlo Park, California, 94303, United States
 
ZIP Code
94303
 
Solicitation Number
SLAC267542
 
Archive Date
8/1/2016
 
Point of Contact
Stefan Lavaire Wilson, Phone: 6509263549
 
E-Mail Address
stefanw@slac.stanford.edu
(stefanw@slac.stanford.edu)
 
Small Business Set-Aside
N/A
 
Description
SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions Sources Sought for the following: #21283 Vacuum probe XS22.112H-140 Technical Data Vacuum Probe Inbuilt length 140...300 mm Diameter 6 mm, with protection tube 16 mm Mass 1,5 kg Dimension clamp head 150 x 63 x 35 mm Protection degree IP54 Flange KF40, others on request Max. temperature at flange 60 °C Power supply 24 V DC +/- 10 % Current consumption 1,2 A Heating power 30 W Pressure range 1,5 x 105...1 x 10-5 Pa Sensor voltage range 0...400 mV oder 0...1200 mV (range changing on curcuit board) Range (oxygen partial pressure) 1 x 105...1 x 10-21 Pa Output signal 0-20 mA Accuracy < 5 % rel. error Sensor working temperature 700 °C (electronically controlled) Offset (with protection sleeve) -15...-20 mV Helium leak rate < 10-8 mbar l/s Gas flow max. 10 m/s Reference gas surrounding air Reference gas flow 5...10 l/h (by internal pump) With Electronic unit E2010.B0 manual Signal input cell und thermal voltage probes Range 0...20.64 Vol.-% O2 (up to 100 Vol.-% on request) Accuracy rel. error < 5 % Reference gas supply via internal pump (flow monitored) Plain text display LCD dot-matrix Keypad 6 membrane keys Digital interface RS232 Output 2 potential free current outputs 0/4...20 mA, adjustable (alternative: voltage output 0...5/10 V) 2 programmable limit values (relay output) alarm message (relay output) Power supply 110-230 V, 50-60 Hz Dimensions 300 x 300 x 120 mm3 Weight approx. 4 kg Protection degree IP65 Working temperature 0...+50 °C, 0...95 % rel. humidity Storage temperature -20...+60 °C, 0...95 % rel. humidity Reply to FBO posting only. SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/SLAC/STAN/SLAC267542/listing.html)
 
Place of Performance
Address: SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, Menlo Park, California, 94025, United States
Zip Code: 94025
 
Record
SN04194462-W 20160727/160725235335-f69a69417c47105590fef4f7e9649f73 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.