Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 04, 2016 FBO #5368
DOCUMENT

65 -- Cryoablation Machine for Radiology Service - Dallas VAMC - Attachment

Notice Date
8/2/2016
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;North Texas Veterans Health Care Center;VISN 17 Network Contracting Activity;4500 S. Lancaster Road;Dallas TX 75216
 
ZIP Code
75216
 
Solicitation Number
VA25716Q1429
 
Response Due
8/5/2016
 
Archive Date
9/4/2016
 
Point of Contact
Matthew A Wendel
 
E-Mail Address
8-0828<br
 
Small Business Set-Aside
N/A
 
Description
Pre-Solicitation Notice - Sources Sought for Veteran Owned Small Businesses The North Texas VA Medical Center located in Dallas, TX intends to issue a solicitation as a 100% small business set-aside for a Cryoablation System as specified below. Prior to issuing this solicitation, NCO 17 is seeking veteran owned small businesses that may be able to offer a response to this solicitation. Interested vendors that are able to provide a response to the below requirements please notify the issuing Contracting Officer via email at matthew.wendel@va.gov prior to 08/05/2016. If we are able to ensure at least two responsive, interested veteran owned small businesses are available, the ensuing solicitation for this requirement will be set aside to veteran owned small businesses. Otherwise, NCO 17 will proceed with issuing this as a 100% small business set-aside. Please note - this initial pre-solicitation notice is for market research and informational purposes. Based on the results, a solicitation will be posted to FBO.Gov for this requirement. Cryoablation System Specifications -26' long gas lines -Argon based system -Built in gas regulators to ensure consistent pressure -Real time gas indicators -Single screen display -Software that plans diagnostics and upcoming maintenance needs -Updatable support software -Single screen for login and setup -Adjustable freeze intensity, with at least 5% increments -Minimum 10 channels for needles with independent control -Up to two needles controllable per channel -Ability to use different needle types during single procedure -Temperature warning settings based on min. temp limit, max. rate of temp. drop
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANTHCS/VANTHCS/VA25716Q1429/listing.html)
 
Document(s)
Attachment
 
File Name: VA257-16-Q-1429 VA257-16-Q-1429.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2916309&FileName=VA257-16-Q-1429-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2916309&FileName=VA257-16-Q-1429-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04205678-W 20160804/160802235736-12650e436b078dddb9069804ec7ace77 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.