Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 06, 2016 FBO #5370
SOURCES SOUGHT

66 -- DATA ACQUISITION SYSTEMS

Notice Date
8/4/2016
 
Notice Type
Sources Sought
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
Department of the Army, Army Contracting Command, ACC - APG (W911QX) Adelphi, 2800 POWDER MILL RD, ADELPHI, Maryland, 20783-1197, United States
 
ZIP Code
20783-1197
 
Solicitation Number
W911QX-16-T-0314
 
Archive Date
8/27/2016
 
Point of Contact
Adrian Barber, Phone: 3013941503
 
E-Mail Address
adrian.t.barber.civ@mail.mil
(adrian.t.barber.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
(11) A. Objective: To find sources that are qualified to meet the supplies/services as listed in section 11B. Note that the specific requirements in section C are subject to change prior to the release of any solicitation. B. REQUIREMENTS: System #1 Qty Part # Description 1 EM-CPU System Processor Module for Echelon IP67 Ruggedized Data Acquisition System. Each Processor Module accepts up to four input modules to support a variety of signal inputs. Standard support for 2 CAN (1 HT Module Dedicated), 16 DI, 4 DO, and 4 Quadratures. Includes AC/DC adapter with DC power cable, 64 GB or larger industrial temperature rated SSD, 2-Port CAN Breakout Cable, 2 Dovetail Endcaps and Aspire Software with single off-line license. 1 EP-BAT Echelon Standard Battery Pack. Provides 80 Wh of continuous based on system configuration. Limits operating temperature to -20 to 70 Deg C. 3 EM-HDO-350 High Density Input Module with Analog Out for Echelon System. Sixteen independent 24-bit, 100 kS/s digitizers, ±10mV to ±4V Input Ranges. On-board support for Full, 1/2 and 1/4 bridges with software selectable excitation for strain measurements. Additional support for accelerometer, thermocouple, higher input range available through external breakout connectors. Includes Analog Out Option. 1 HT-TCS-K IP67 Sealed Sixteen Channel CAN/USB Isolated Type-K Thermocouple Module for PC, Synergy and Echelon Systems. -40 to 80C operating temperature, ADC per channel, 10 S/s sampling rate, 500 V channel-to-channel, channel-to-ground isolation. Requires additional cable for connection to Synergy, PC, or Echelon. 1 EP-UP-S256 Internal Industrial Temperature Rated 256 GB Solid State Drive Upgrade for Echelon System. Option replaces standard 64 GB SSD drive with 256 GB Drive (EA-SSD-256). 3 EC-HDO-BNC Echelon High-Density Input Module Analog Out BNC Breakout Cable. Supports 16 Channels. 1 EC-TC-CN-10 Thermocouple Module to Echelon Chassis CAN Connection Cable. Connects HT-TC to Echelon Chassis. Includes terminator. [10 Meters] 6 EC-HD-FL Echelon High-Density Input Module 8-Channel Flying Lead Breakout Cable. Supports EM-HD and EM-HL Modules. 6 EC-HD-BNC Echelon High-Density Input Module 8-Channel BNC Breakout Cable. Supports EM-HD and EM-HL Modules. 2 EC-HD-IEPE Echelon IEPE Connection Cable. Extends capability of EM-HD and EM-HL to support IEPE type sensors. Cable supports 8 Channels. Adapts 62-pin male connector to individual male BNC input connectors. Individual channel jumpers allow channel by channel switching for DC, AC, or IEPE inputs types. SYSTEM #2 1 EM-CPU System Processor Module for Echelon IP67 Ruggedized Data Acquisition System. Each Processor Module accepts up to four input modules to support a variety of signal inputs. Standard support for 2 CAN (1 HT Module Dedicated), 16 DI, 4 DO, and 4 Quadratures. Includes AC/DC adapter with DC power cable, 64 GB or larger industrial temperature rated SSD, 2-Port CAN Breakout Cable, 2 Dovetail Endcaps and Aspire Software with single off-line license. 1 EP-BAT Echelon Standard Battery Pack. Provides 80 Wh of continuous based on system configuration. Limits operating temperature to -20 to 70 Deg C. 4 EM-HS High-Speed Universal Input Module for Echelon System. Four independent 16-bit, 1 MS/s SAR type digitizers. Universal inputs support channel by channel direct connections for voltage, bridge, accelerometer and thermocouple measurements. 1 EP-UP-S256 Internal Industrial Temperature Rated 256 GB Solid State Drive Upgrade for Echelon System. Option replaces standard 64 GB SSD drive with 256 GB Drive (EA-SSD-256). 4 EC-HD-FL Echelon High-Density Input Module 8-Channel Flying Lead Breakout Cable. Supports EM-HD and EM-HL Modules. 1 TRAINING On-Site Echelon / Aspire Training for one full day, up to 10 Attendees 2 FREIGHT Shipping charges per system C. Responses: All interested parties should notify this office by e-mail within the posted date. Responses shall include: (I) To what extent each of the specifications can be met. (II) Include your type of business (i.e. commercial, academia), whether your organization is classified as a large or small business based on the 750 employee size standard that accompanies NAICS code 334515. If a small business, you must also list any small disadvantaged status you hold [HUBZone, 8(a), Service Disabled Veteran Owned Small Business (SDVOSB), Women Owned Small Business (WOSB), Economically Disadvantaged Women-Owned Small Business (EDWOSB), etc.]. (III) Past experience/ performance through the description of completed projects. (12) Responses to this sources sought synopsis are due no later than 11:59 AM eastern standard time 8/12/2016. Submissions should be emailed to Adrian Barber adrian.t.barber.civ@mail.mil. Questions concerning this sources sought synopsis may be directed to Adrian Barber at adrian.t.barber.civ@mail.mil or 301-394-1503. Please be advised that.zip and.exe files cannot be accepted. (13) Place of Contract Performance: The Army Research Laboratory, Aberdeen Proving Ground (APG), MD 21005-5001. (14) Estimated Delivery Timeframe or Period of Performance: 10 weeks ARO
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/75eb27c27742d780b150bba7db5d4f2d)
 
Place of Performance
Address: The Army Research Laboratory, APG, Maryland, 21005-5001, United States
Zip Code: 21005-5001
 
Record
SN04208849-W 20160806/160804234509-75eb27c27742d780b150bba7db5d4f2d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.