DOCUMENT
C -- A/E for NRM Project 580-16-101 Upgrade to Emergency Power System - Attachment
- Notice Date
- 8/4/2016
- Notice Type
- Attachment
- NAICS
- 541330
— Engineering Services
- Contracting Office
- Department of Veterans Affairs;NCO 16;Michael E. DeBakey VA Medical Center;2002 Holcombe BLVD;Houston TX 77030 4298
- Solicitation Number
- VA25616R1174
- Response Due
- 8/25/2016
- Archive Date
- 9/24/2016
- Point of Contact
- Tabitha K Contreras
- E-Mail Address
-
4-7513<br
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- 1.CONTRACT INFORMATION: General. A-E Services are being procured in accordance with the Selection of Architects and Engineers Statute (Public Law 92-582), formerly known as the Brooks Act, and implement in Federal Acquisition Regulation (FAR) 36.6. All submissions will be evaluated in accordance with the evaluation criteria. The three firms deemed most highly rated after initial source selection will be chosen for interviews. The Government will not pay, nor reimburse, any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. Firms will be selected based on demonstrated competence and qualifications for the required work. The NAICS Code for this acquisition is 541330, Engineering Services, and the applicable Small Business Size Standard is $15 million. a. Contract Award Procedure: The proposed A/E services will be obtained by a Negotiated Firm-Fixed Price Contract. Interested parties shall ensure current Licensing and have a current registration in the System for Award Management (SAM) database at https://www.sam.gov/portal and the Vendor Information Pages database at https://www.vip.vetbiz.gov/ as well as have submitted the current cycle VETS-100 Report per the requirements located at http://www.dol/gov/vets/contractor/main.htm. Failure of a proposed SDVOSB to be certified by the CVE at the time the SF 330 is submitted shall result in elimination from consideration as a proposed contractor. b.SDVOSB Requirements: In accordance with VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside, a service disabled veteran-owned small business concern agrees that, in the performance of the contract, at least 50 percent of the cost of personnel for contract performance will be spent for employees of the concern or employees of other service-disabled veteran-owned small business concerns. c.Nature of Work: Provide Architectural/Engineering (A/E) services for site survey and investigation, concept development, design development, preliminary drawings, construction drawings, specifications, cost estimates, and construction period services. The A/E will work with VA Project Management Staff to develop the necessary working drawings, phasing plans, infection control plans, contract specifications, prioritization of items, and cost estimates for full and complete construction of this project. d.Design Costs: All offerors are advised that in accordance with VAAR 836.606-73(a) the total cost of the architect or engineer services contracted for must not exceed 6 percent of the estimated cost of the construction project plus any fees for related services and activities. Additionally, FAR 52.236-22 Design Within Funding Limitations, will be applicable to this procurement action. Design limitation costs will be provided to the most highly rated AE firm selected to complete the design. The magnitude for construction (not design) of this project is between $1 million and $2 million. 2.SELECTION CRITERIA: The selection criteria for this acquisition will be in accordance with FAR 36.602-1 and VAAR 836.602-1 and are listed below in descending order of importance. (1)Professional qualifications necessary for satisfactory performance of required services to include reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness. a.Provide brief resumes of proposed team members who will specifically serve as the Project Managers and Designers of Record (Mechanical, Electrical and Fire Protection Engineer). In addition, provide resumes of other relevant team members or frequent subcontractor such as: Architect, Civil, Structural Engineers, Cost Estimator and team members who will perform technical tasks under this contract including their record of working together. b.The Designers of Record shall perform and direct the design within their respective discipline and shall sign and seal the drawings. All Designers of Record must be professionally registered in their discipline. Each resume shall include a minimum of five (5) and a maximum of seven (7) specific completed projects in the past five (5) years that best illustrate the individual team members experience relevant to this contract scope. (2)Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials and their record of working together as a team. a.Provide a detailed narrative of a minimum of five (5) up to seven (7) maximum relevant projects completed within the last 5 years, which best illustrate overall team experience relevant to this contract scope. List projects that demonstrate the teams experience with projects of similar size and scope to those to be performed under this contract; Specific design areas to be evaluated within this factor are: 1.Experience in designing renovations and upgrades to existing Type 1 Essential Electrical Systems (EES)/ Level 1 Emergency Power Supply Systems (EPSSs) as per NFPA 99 and NFPA 110 2.VA Hospital Experience 3.Phasing Construction Projects 4.Environmental Assessment & Abatement; including, but not limited to, Asbestos and Lead 5.Verification of Exceptional Customer Service; including customer service awards received 6.Building Energy Modeling per ASHRAE 90.1-2010 or 2013 7.Designs that comply with ASHRAE 90.1-2010 or 2013 8.Familiarity with and experience incorporating the requirements of current or recent VA guidance documents related to Sustainable Buildings (3)Capacity to accomplish the work in the required time. a.This factor evaluates ability of the AE firm, given their current projected workload and the availability of their key personnel, to accomplish the possible myriad of design projects in the required time. The general workload and staffing capacity of the design office will be evaluated. 1.List current projects with a design fee of greater than $20,000 being designed in the firm's office in the past five (5) years; 2.Indicate the firms' present workload and the availability of the project team (including sub-consultants) for the specified contract performance period; 3.Describe experience in successfully delivering projects per performance schedule, providing timely construction support and successfully completing multiple projects with similar delivery dates. (4)Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. Record of significant claims against the firm because of improper or incomplete architectural and engineering services. (5)Location in the general geographical area of the project and knowledge of the locality of the project. Provide the address and distance of your office to MEDVAMC. The distance shall be determined using http://maps.google.com (6)Ability to comply with FAR clause 52.219-14. Firms must demonstrate how they will comply with the requirement to meet FAR Clause 52.219-14, at least 50 percent of the cost of contract performance incurred for personnel shall be expended for employees of the concern. 3.SUBMITTAL REQUIREMENT: This project is a 100% set-aside for Service-Disabled Veteran Owned Small Business (SDVOSB) concerns under VAAR 852.219-10, VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside (Dec 2009). All original Standard Form (SF) 330 packages shall be submitted to: Michael E. DeBakey Veterans Affairs Medical Center (90C) Network Contracting Office (NCO 16) Attn: Tabitha Contreras, Room 4B-313 2002 Holcombe Boulevard Houston, TX 77030 (a) All SF 330 submissions shall be clearly marked with the subject line displaying the Solicitation Number VA256-16-R-1174. The SF 330 form may be downloaded from www.gsa.gov/forms. Completed SF 330's shall include the primary firms, subcontractor firms, and any consultants expected to be used on the project. There is no page limit, required margin size, etc. for the submission; it is expected for interested firms to be concise and clear. Questions for this announcement are due by 4PM Central on August 11, 2016. (b) Firms that meet the requirements listed in this announcement are invited to submit three (3) copies of the completed SF 330 including Parts I and II as described herein and one CD-ROM of the SF 330 submittal as a single pdf file, to the above address no later than 11:00 A.M. Central on August 25, 2016. FAX AND/OR E-MAIL SUBMISSIONS WILL NOT BE ACCEPTED. Late proposal rules found in FAR 15.208 will be followed for late submittals. (c) Interested firms shall address each of the six (6) Selection Criteria in their SF 330's and additional documents/submittals. 4.THIS IS NOT A REQUEST FOR PROPOSAL. THERE ARE NO SOLICITATION DOCUMENTS AVAILABLE. This is a request for SF 330's Architect/Engineer Qualifications packages only. Any requests for a solicitation will not receive a response. This requirement is subject to Availability of Funds. 5.PROJECT INFORMATION: A/E Design Scope of Work 1.0 SCOPE 1.1The Architect/Engineer shall furnish all professional and technical expertise to develop Schematics, pre-design preliminaries, design drawings, specifications, cost estimates and construction contract bid documents to include design of the replacing components of the existing emergency power system at the Michael E. DeBakey VA Medical Center to include: -Replacement of the 6000A Zenith paralleling switchgear located in Building 106 with new gear sized appropriately for the fault current. -Replacement of the six 700kW Caterpiller emergency generators -Repair/renovation of areas containing ATS (Automatic Transfer Switches) #1-12 that are subject to moisture intrusion and in need of corrective measures to seal roof penetrations above. -Replacement of approximately 49 ATS units in Building 100. The A/E will prepare equipment layouts for new equipment as required by the equipment's manufacturer specifications and drawings. 1.2The A/E shall provide construction period services including "as built," responses to RFIs, and site visits. 2.0 PROJECT OVERVIEW 2.1The A/E shall develop conceptual plans for VA selection. The selected plan will be developed further to include space programs and related details. All designs must adhere to JCAHO, NFPA, and life safety latest requirements. 2.2The Architect/Engineer shall survey the area and verify existing space, study adequacy of square footage for each function, analyze utility systems and verify as built drawings. Existing drawings may not be complete or fully accurate. The A/E contractor shall make sufficient site investigations to evaluate all existing conditions. The A/E contractor shall obtain additional pertinent information, as needed, from the COR, to ensure the completion of an efficient, comprehensive design. 2.3The completed preliminary plans shall include a detailed construction, equipment, and project cost estimates. The A/E is responsible to design the project within available budget and provide recommendations of deduct items as alternatives. 2.4The A/E shall thoroughly study existing drawings and building design criteria for exact implementation and coordination of all systems and components of the new renovations, and avoidance of construction conflicts. All features and systems shall conforms to the existing design criteria of building 100 which mandates runs of all utility systems such as electrical and mechanical systems, air ducts, piping, conduits, etc. in the interstitial space only. Installations of equipment in the interstitial space are prohibited. 3.0 DESIGN SUBMITTALS 3.1The following contractual periods of performance shall begin from the award date of the contract. 3.2Final submittals shall include two (2) original hard copies and two (2) CD-ROM discs for drawings using AutoCAD version 2011 and Specifications using Microsoft Word latest version. All electronic submittals must adhere to VA requirements. 3.3Room's square footage and dimensions must be indicated on the floor plan. 3.4The A/E will submit 35 percent, 75 percent, 95 percent, and final design bid packages for review and approval. VA shall respond with comments within seven calendar days after the receipt of each submittal. 3.5Each submission will include two complete half-size sets of Drawings, five full-size Architectural Floor Plans, and two CD-ROMs. 4.0 SAFETY 4.1The A/E is responsible to retain services of a licensed Fire Protection Professional Engineer. The FPE is required to conduct a fire protection and life safety review as per VA Directive 2005-007. 4.2Review and seal As-Built drawings prepared by the contractor. 4.3Certification of the fire protection systems will be performed by an independent third party engaged by the VA. Certification of the fire protection systems will not be part of the A/E Services. 4.4The A/E will provide a performance specification for revisions to the existing sprinkler system. 4.5The VA will provide the A/E with the existing facility life safety plan and analysis, including the location of smoke compartments and related partitions and life safety egress. 5.0 SUSTAINABLE DESIGN STANDARDS 5.1The A/E shall be responsible for designing to achieve sustainable design equivalencies and for implementing within the design the following Guiding Principles found in the Federal Leadership on High Performance and Sustainable Buildings Memorandum of Understanding and the VA Sustainable Design and Energy Reduction Manual: Employ Integrated Design Principles (Integrated Design) Optimize Energy Performance (Energy Efficiency, Measurement and Verification) See attached Energy Efficiency Design Standards document. Protect and Conserve Water (Indoor Water, Outdoor Water) Enhance Indoor Environmental Quality (Ventilation, Thermal Comfort, Moisture Control, Day lighting, Low-Emitting Materials, and Protect IAQ during Construction) Reduce Environmental Impact of Materials (Recycled Content, Bio-based Content, Construction Waste, Ozone Depleting Compounds) 5.2Sustainable design features, activities and equivalencies are part of overall Federal policy to limit environmental impact and ensure the environmental compatibility of Federal facilities. It is the intent of the VA to make every reasonable and rational effort to meet these requirements. In the event the A/E concludes that implementation of specific sustainability requirements is not feasible (in that doing so creates major negative impacts on the project, including major overall cost increases, major operational feasibility issues, major technology application issues, etc.), a detailed rationale for limiting the use of the specific sustainability feature in question shall be submitted in writing to the Project Engineer for consideration. Such rationale shall include discussion of the significant negative impacts to the project. Cost comparisons and evaluations used in supporting the non-inclusion of required sustainability features must show an overwhelming life cycle rationale. Such exclusions shall not be implemented unless specifically approved by the Project Engineer. 5.3Commissioning of systems is not included as part of the A/E Services. 6.0 ARCHITECTURAL 6.1One-eighth- (1/8-) inch scale floor plans shall be submitted with the following neatly displayed: "Room names, numbers, square footage, functions, and appropriate activity codes. "Reflected ceiling plans "Net square foot program area of each room with the corresponding designed net square foot area. (Program vs. Actual). "All corridors, electrical closets, telephone closets, equipment rooms, mechanical shafts and spaces vertical circulation spaces (stairs, dumbwaiters, etc.) and automatic conveyances. "All plumbing fixtures, doors and swings "Doors and Finish schedules "Locations of all smoke and fire partitions. 6.2One-eighth inch scale floor plans showing and identifying equipment utilities requirements for each room shall be submitted. Equipment floor plans are required for all medical equipment, offices, consultation rooms, classrooms, conference rooms, and waiting rooms. 6.3A written narrative describing the interior design scheme of existing spaces and how reworked areas will integrate functionally and aesthetically with the remainder of the hospital building shall be submitted. All variations from criteria shall be explained. 7.0STRUCTURAL 7.1The structural integrity of the existing building shall be considered in the renovation and placement of all new equipment. The building structural system (including slabs, girders, beams, and columns) shall be reinforced as necessary to accommodate all new loads. Structural design shall comply with all applicable codes. 7.2Construction drawings shall include at least one plan view showing all structural columns, beams and typical floor plan features. The structural members shall be properly dimensioned, including depth and width of beams. Sufficient elevation views shall also be included on the drawing to show minimum heights from floor to lower surface of beams and/or interstitial purlins and deck. 7.3 AE to use VA provided details to penetrate interstitial space. 8.0HEATING, VENTILATING AND CONDITIONING 8.1Provide preliminary load and sizing calculations for all HVAC systems. 8.2Provide a written description/narrative of the HVAC requirements and how these requirements will be satisfied. Include a description of all new systems (including controls) and how they will interface with existing systems. Investigate design alternatives and justify the selected system(s), highlighting economics, energy conservation, and other pertinent considerations; provide reference sources for all data included. Assure that all systems, at minimum, meet VA standards for type of area served. 8.3Submit duct and piping layouts for the area. 8.4Provide one-eighth inch scale floor plans showing the HVAC and steam distribution equipment. Coordinate the design with other disciplines. 8.5Provide flow and control diagrams for steam, condensate, hot water, chilled water, and condenser water. Provide sequence of operations and controls for all HVAC systems and equipment. 8.6Provide preliminary design for fire and safety systems that are associated with the HVAC systems. Show the fire and safety design on the HVAC dampers, coordinate penetrations of interstitial deck with VA to maintain the custom fire rating of the deck system. 8.7Where existing central refrigeration of HVAC systems are retained and modified to serve new or existing areas, show what steps must be taken for proper functioning of the integrated systems. 8.8For all existing buildings were modifications of existing air, water (hot and chilled), or steam is required, show riser diagrams with points of interface of existing and new work. 8.9Provide demolition drawings showing the extent of removal for exiting systems and equipment. 9.0PLUMBING 9.1The project will replace existing plumbing fixtures and medical gases systems in the interstitial space and floor layout. 9.2One-eighth-inch scale plumbing floor plans shall be submitted. Plumbing fixtures shall be identified; plumbing lines shall be sized. 9.3Floor plans, elevations, and sections shall be developed showing all required equipment. 9.4All calculations supporting the design shall be submitted. 10.0SPRINKLER 10.1The project will modify the sprinkler system in the area as needed to maintain code compliance for which Building 100 was originally designed. 10.2The locations of new smoke and fire partitions and boundaries of smoke, fire, and sprinkler zones shall be displayed. The system shall be properly interfaced with the existing sprinkler system. 10.3Use of quick response sprinkler heads is mandatory. 10.4The A/E will provide a performance specification for the sprinkler system. 11.0ELECTRICAL 11.1The project will replace the entire electrical distribution, including raceways, circuitry, panels, wiring devices, lighting fixtures, equipment, etc. The data and telephone systems will be modified to accommodate the new areas. New electrical feeders shall be provided as required by the new calculated electrical loads. 11.2One-eighth inch scale floor plans shall be submitted. The plans shall indicate room (or area) numbers, titles, and functions. The locations of all lighting fixtures, outlets for power, communication/signal outlets and devices, fire alarm devices, and equipment shall be displayed. The electrical floor plans shall show smoke and fire partitions and zones. 11.3One-quarter inch scale elevations shall be provided to display design details. 11.4Reflected ceiling plans shall show lighting layout, registers, chases, smoke detectors, page speakers, and other overhead equipment. One-line diagrams of the normal and emergency electrical power distribution system shall be submitted. Include low voltage main and secondary power distribution panels. Verify that existing feeders to be reused are adequately sized for the proposed project. Preliminary design data, assumptions, and calculations shall be submitted. 11.5The existing electrical distribution system and electrical panels will be replaced as required. 11.6Low-Voltage Systems: A/E will indicate locations of devices for installation of conduit and back boxes according to information received from the VA. These devices include fire alarm, nurse call, security systems, paging, and CATV. 12.0 CONSTRUCTON COST ESTIMATE 12.1The preliminary cost estimates shall reflect the expected construction cost for all work identified and detailed. "Magnitude" and "square foot" estimates will not be accepted. 12.2The A/E shall develop a detailed preliminary construction cost estimate. The cost estimate shall present labor, material, and equipment costs for work required by the major disciplines, i.e., Architectural, Structural, Mechanical, Plumbing, Sprinkler, Electrical, and Industrial Hygiene. The work grouped under each major discipline shall be placed into the appropriate VA Master Construction Specification Division (CSI format). 12.3The detailed construction cost estimate shall consider contingencies at 7.5% overhead at 10%, profit at 10%, and escalation attributable to inflation, and any other regional industry costs. The contingency amount is established for change orders or other additional work occurring during construction. 12.4The estimate must have sufficient detail and accuracy to reflect the anticipated bid cost upon completion of the contract working drawings and specifications. Cost estimate must include bid deduct(s) that total at least 20% of the construction estimate. 13.0 MEETINGS 13.1Post-award Meeting - A post award meeting will be held within ten (10) calendar days after contract award. 13.2Design Review Meetings - A design review meeting will be held after each design submittal. 13.3 Meeting Minutes - The A/E Contractor shall take minutes of all meetings held relative to this contract with exception to the construction phase. The format must be acceptable to the Contracting Officer (CO). Minutes must include the meeting date and time; agenda; meeting location; list of participants with their affiliations, and telephone numbers; be fully descriptive of issues, problems and decisions made; and action items with names of responsible parties and deadlines. In addition, the minutes must include, as attachments, all exhibits and references distributed as handout materials, unless the materials are part of a formal submission. The A/E Contractor shall provide, via email transmission, complete copies of all minutes to CO and all attendees within 48 hours of the next meeting. All challenges to the minutes will be reflected in a revised version prepared by the A/E Contractor. Copies of updated minutes shall be distributed to the CO and all attendees within 24 hours after change notice. 14.0 QUALITY CONTROL 14.1The contractor shall develop a quality plan. This plan shall be submitted as part of the contractor's cost proposal. The plan should outline the following: "The management and organization of this project. "Intended key technical personnel, such as subcontractors, discipline managers, project manager, etc. "Narrative describing product quality control. 14.2After the award of the contract, the A/E Contractor shall follow minimum standards of quality as follows: "There shall be a consistency of key personnel throughout the project. "All deliverables shall be routed through, reviewed and approved by the A/E contractor project manager. "All mistakes, omissions or errors discovered during the construction process shall be rectified by the A/E contractor. The A/E contractor shall provide the government with additional design drawings, cost estimates and statement of work to make field design corrections, should they become necessary. 15.0 GENERAL INFORMATION: 15.1 The A/E contractor shall submit all request for information in writing to the COR and allow at least three working days for the COR to respond. 15.2 The Contracting Officer must approve all work that is beyond the scope of this statement of work. END OF STATEMENT OF WORK
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/HoVAMC/VAMCCO80220/VA25616R1174/listing.html)
- Document(s)
- Attachment
- File Name: VA256-16-R-1174 VA256-16-R-1174.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2923411&FileName=VA256-16-R-1174-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2923411&FileName=VA256-16-R-1174-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA256-16-R-1174 VA256-16-R-1174.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2923411&FileName=VA256-16-R-1174-000.docx)
- Record
- SN04209203-W 20160806/160804234833-2d70e986e6e27233828c2bf7f8b132de (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |