Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 06, 2016 FBO #5370
SOLICITATION NOTICE

41 -- ENVIRONMENTAL CONTROL UNITS/TEMPERATURE CONTROL OF SHELTERS OR CHAMBERS IN HARSH ENVIRONMENTS - 16T0158_sol - 16T0158_att

Notice Date
8/4/2016
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
Department of the Navy, Naval Sea Systems Command, NSWC Crane Division, 300 Highway 361, Building 3373, Crane, Indiana, 47522-5001, United States
 
ZIP Code
47522-5001
 
Solicitation Number
N0016416T0158
 
Archive Date
9/29/2016
 
Point of Contact
Theresa Jones, Phone: 812-854-4338
 
E-Mail Address
theresa.a.jones2@navy.mil
(theresa.a.jones2@navy.mil)
 
Small Business Set-Aside
N/A
 
Description
16T0158_att 16T0158_sol N00164-16-T-0158 ENVIRONMENTAL CONTROL UNITS/TEMPERATURE CONTROL OF SHELTERS OR CHAMBERS IN HARSH ENVIRONMENTS - FSC - 4120 OCC 31.0 - NAICS - 333415 Issue Date: 04 August 2016 Closing Date: 15August, 2016 Time 3:00 P.M. EDT This solicitation is being posted to both the Federal Business Opportunities (FBO) page located at http://www.fbo.gov/. While it is understood that FBO is the single point of entry for posting of synopsis and solicitations to the internet. Please feel free to use the FBO site to access information posted by NSWC Crane. Naval Surface Warfare Center (NSWC) Crane Division intends to solicit, negotiate, and enter into a Firm Fixed Price Commercial Supply Contract IAW FAR 13, Simplified Acquisition Procedures for the following procurement: CLIN0001 Environmental Control Unit QTY 18 SPECIFICATIONS: 1. Mechanical Dimensions: a. Maximum Height shall not exceed 52.125" (-2.00" / +0.000") b. Maximum Width shall not exceed 18.00" (-2.00" / +0.00") c. Maximum Depth shall not exceed 11.00" (-2.00" / +0.00") d. Hot side air inlet shall be located on the left side of the ECU cabinet. e. Hot side air outlet shall be located on the front side of the ECU cabinet. f. Cold side air inlet and outlet shall be located on the back side and in the upper quadrant of the backside panel, and the cold side inlet shall be located below the cold side outlet. g. Power cord and access to remote control shall be located on the backside. Note: The specifications are provided for reference use only. The ECU height and hot side air inlet and outlet positions, cold side air inlet and outlet positions, power cord location, and remote control interface location are critical to the I1B1 Receiver / Transmitter (R/T) system integration with the I1B1 Fixed Site Shelter. For reference purposes, the ECU "back" shall be the panel which mounts to the R/T pod and through which the conditioned air passes. Left, right, and front sides are defined relative to the back side, accordingly. Positions of conditioned air inlets and outlets are critical to R/T pod and include electronics air flow dynamics. 2. Performance Characteristics: a. Nominal cooling capacity at standard temperature, humidity, and pressure: 8,000 BTU/HR, minimum b. HFC refrigerant (reference Air Force Pamphlet 32-7089 Section A12.3.2 - Alternates to R-22). This pamphlet is provided as Government Furnished Information (GFI). c. Power Source: 120 Vac, Single Phase, 60 Hz d. Maximum Current (including starting current); 15 Amperes e. Heating capacity: 400 Watts (nominal) f. Maintain NEMA 4X environmental protection rating. g. Requires built-in condensate evaporation h. Requires remote (auxiliary) control and display unit. i. Unit shall be designed for sustained high ambient temperature operation. The ECU shall continue to operate at +135° F ambient temperature. j. Based upon the R?T equipment suite heat dissipation requirement, the ECU shall be capable of developing a minimum of 6,400 BTU/HR cooling capacity while maintaining return air at +105° F, against ambient air temperature of +130° F. 3. Reliability and Maintainability Requirements: a. The mean time to perform preventive maintenance shall not exceed 15 minutes. b. The mean time between critical failures shall be greater than or equal to: 50,000 hours. (Critical failures are defined as failure of the compressor, fans, condenser, or controller.) Inspection and Acceptance is to be at destination with deliver F.O.B. Destination: NSWC Crane, IN 47522-5001. To be eligible for award of a Government contract, contractors must be properly registered in the System for Award Management (SAM). The link to the website is https://www.sam.gov All changes to the requirement that occur prior to the closing date will be posted in FedBizOpps. It is the responsibility of interested vendors to monitor the FedBizOpps for amendments that may be issued to this solicitation. For changes made after the closing date, only those offerors that provide a proposal will be provided any changes/amendments and considered for future discussions and/or award. No hard copies of the solicitation will be mailed. Quotes must be submitted in the format specified in the solicitation. It is the responsibility of the offeror to submit offers to the POC at NSWC Crane. The POC is Ms. Theresa Jones, Code 0253, Telephone 812-854-4338. Offers may be emailed to Theresa.a.jones2@navy.mil. All required information must be received on or before 15 August 2016. Time 3:00 P.M.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVSEA/N00164/N0016416T0158/listing.html)
 
Record
SN04209598-W 20160806/160804235138-63b53bcb222d0b0ddaca0b4577160b20 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.