Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 13, 2016 FBO #5377
DOCUMENT

H -- Medical Gas Inspection Service to include four (4) Option Periods - Attachment

Notice Date
8/11/2016
 
Notice Type
Attachment
 
NAICS
811219 — Other Electronic and Precision Equipment Repair and Maintenance
 
Contracting Office
Department of Veterans Affairs;VA Healthcare System;Network Contracting Office (NCO) 10;3140 Governor ™s Place Blvd. Suite 210;Kettering OH 45409-1337
 
ZIP Code
45409-1337
 
Solicitation Number
VA25016Q0522
 
Response Due
8/19/2016
 
Archive Date
10/3/2016
 
Point of Contact
Adoniss Gibson
 
E-Mail Address
Network Contracting Office (NCO) 10
(Adoniss.Gibson@va.gov)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Statement of Work - Annual Medical Gas Inspection Annual Evaluation of the piped OXYGEN, NITROUS OXIDE, MEDICAL AIR, DENTAL AIR, MEDICAL VACUUM, DENTAL VACUUM, NITROGEN and EVACUATION/WAGD Systems, in accordance with JCAHO (Joint Commission on Accreditation of Healthcare Organizations) 2016 standards, CGA (Compressed Gas Association) standards, NFPA 99 (National Fire Protection Association) 2015 standards, ASSE (American Society of Sanitary Engineering 6000, 2006), and USP/NF (United States Pharmacopeia Convention) requirements and recommendations. All equipment is located on the Dayton VAMC Campus located at 4100 West 3rd Street, Dayton OH 45428. All work shall be completed by September 30, 2016 and a written report shall be provided within 30 days after on site work. The report shall include all findings, note what was checked and the location, and reference applicable code sections. The report shall also provide a concise listing of discrepancies for inlet/outlets, alarm panels, source equipment, and zone valves (example provided below); this concise listing shall provide location (building and floor), room number, discrepancy, NFPA code that discrepancy applies to, recommended resolution for discrepancy, and any additional notes. Deficiencies noted shall be communicated to the COR within 24 hours of discovery and include a recommendation for remediation. The contractor should provide adequate staff to monitor up to 3 master alarm panels and sources when checking the source alarms (minimum of 4 contractors needed). The contractor may have to work outside the usual hours of 7am-4:30pm due to clinical need in some areas such as surgery, recovery room, GI clinic and emergency department. Work shall be coordinated with Biomedical Engineering. Inspection shall include checking of all source valves. The VA will provide a technician to accompany the contractor when checking source valves. Contractor shall check ALL outlets/inlets, skipping those in use and noting them on the report. All bidders must be certified to inspect medical gas systems and shall include a copy of the certification with their final report. Example of discrepancy listing for report: LocationRoomDiscrepancyNFPA NoteRecommended Resolution Include Building and floorRoom#Description of the discrepancyNFPA code that discrepancy applies toAdditional notesThe recommended resolution for discrepancy Bldg. 330, 3 South3D101Oxygen outlet is leaking while in useNFPA 99 ¦Replace O-rings Systems, approximate outlet count, and equipment to be inspected include: Medical Gas Sources - Bldg. 330, Bldg. 310, Bldg. 320, and Bldg. 315 Oxygen - 2 Bulk Sites Medical Air - 4 Compressor Sets Vacuum - 5 Compressor Sets Nitrous Oxide - 2 Manifolds Nitrogen - 2 Manifold Dental Air Tower - 1 Compressor set Zone Valve Shutoffs Tower Complex - 192 Bldg. 320 - 4 Bldg. 315 - 3 Zone Warning Alarm Panels Tower Complex - 108 Bldg. 315 - 2 Master Alarm Panels Tower Complex - 3 Bldg. 320 - 2 Medical Gas Outlets -Tower Complex (Building 330, 310, 315) Oxygen - 562 Medical Air - 563 Vacuum - 666 EVAC - 2 Nitrous Oxide - 17 Nitrogen - 10 CO - 2 CO2 - 2 Medical Gas Outlets - Bldg. 320 Oxygen - 40 Vacuum - 40 Medical Air - 40 Performance of JCAHO 2016 and NFPA 99 2015 required testing includes but is not limited to the following: *Note - Where states to check for brazing, labeling, hanging, etc. it is not expected for the contractor to lift every ceiling type but to inspect these items where there are no ceiling tiles (such as mechanical rooms). Please note that ceiling tiles will have to be removed to test pressure switches. MEDICAL OXYGEN SYSTEM "Tested area alarms for proper pressure switch location and alarm function. "Tested Oxygen system for concentration and gaseous purity at each outlet. "Tested Oxygen for particulate contamination at least once in each zone. oTested with 0.45 micron filter device. "Tested Oxygen system for pressure at each zone. "Tested each Oxygen outlet for proper function, identification, adaptation and mechanical integrity. oIdentified leaking/malfunctioning outlets oIdentified outlets delivering substandard pressure/flow rates "Tested Oxygen zone shut-off valves for proper function, identification and mechanical integrity. "Checked Oxygen pipeline for proper identification labeling. "Tested each zone for available flow. "Tested operational pressure tests at each station outlet/inlet "Tested each critical care outlet operational pressure test oTested outlet flow rate and pressure drop with high demand at adjacent outlets. "Tested Oxygen system components for leakage. "Checked Oxygen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.) "Checked for crossed lines. MEDICAL AIR SYSTEM "Tested area alarms for proper pressure switch location and alarm function. "Tested Medical Air system gaseous purity. (Oxygen Concentration, Gaseous Hydrocarbons, Liquid Hydrocarbons, Carbon Monoxide, Carbon Dioxide, etc.). oTested at source sample valve. oTested Medical Air for particulate contamination at least once in each zone. oTested with 0.45 micron filter device "Tested source for dew point. "Tested medical Air System for pressure at each zone. "Tested each Medical Air outlet for proper function, identification, adaptation, and mechanical integrity. oIdentified leaking/malfunctioning outlets oIdentified outlets delivering substandard pressure/flow rates "Tested Medical Air zone shut-off valves for proper function, identification, and mechanical integrity. "Checked Medical Air pipeline for proper identification labeling "Tested each zone for available flow. "Tested operational pressure tests at each station outlet/inlet "Tested each critical care outlet operational pressure test. oTested outlet flow rate and pressure drop with high demand at adjacent outlets "Tested Medical Air System components for leakage. "Checked Medical Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.) "Checked for crossed lines. MEDICAL SURGICAL VACUUM SYSTEM "Tested area alarms for proper pressure switch location and alarm function "Tested each Vacuum inlet for available flow rate SCFM "Tested operational pressure tests at each station outlet/inlet oTested each Vacuum inlet for proper function, identification, adaptation, and mechanical integrity. oIdentified leaking/malfunctioning inlets oIdentified inlets delivering substandard vacuum/flow rate "Tested all Vacuum zone valves for proper function, identification, and mechanical integrity "Checked Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). "Checked for crossed lines. NITROGEN SYSTEM "Tested area alarms for proper pressure switch location and alarm function oTested Nitrogen system for particulate contamination. oTested with 0.45 micron filter device "Tested Nitrogen system for pressure at each zone. "Tested Nitrogen system outlets for proper function, identification, adaptation, and mechanical integrity. oIdentified leaking/malfunctioning outlets oIdentified outlets delivering substandard pressure/flow rate "Tested Nitrogen zone shut-off valve for proper function, identification, and mechanical integrity. "Checked Nitrogen pipeline for proper identification labeling. "Tested Nitrogen control panels for leakage and proper operation. "Checked Nitrogen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.) "Checked for crossed lines. "Check flexible connectors. NITROUS OXIDE SYSTEM "Tested area alarms for proper pressure switch location and alarm function "Tested Nitrous Oxide system for concentration oTested Nitrous Oxide system for particulate contamination. oTested with 0.45 micron filter device "Tested Nitrous Oxide system for pressure at each zone. "Tested each Nitrous Oxide outlet for proper function, identification, adaptation, and mechanical integrity. oIdentified leaking/malfunctioning outlets oIdentified outlets delivering substandard pressure/flow rates "Tested Nitrous Oxide zone shut-off valves for proper function, identification, and mechanical integrity. "Checked Nitrous Oxide pipeline for proper identification labeling. "Tested each Nitrous Oxide outlet for available flow. "Tested Nitrous Oxide pipeline components for leakage. "Checked Nitrous Oxide system components for proper installation (i.e.: Brazing, Labeling, - Hanging, etc.) "Checked for crossed lines. "Check flexible connectors. DENTAL AIR SYSTEM "Tested Dental Air system for pressure "Tested Dental Air zone shut-off valves for proper function, identification, and mechanical integrity. "Checked Dental Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). "Checked for crossed lines EVACUATION/WAGD "Tested area alarms for proper pressure switch location and alarm function "Tested inches (of mercury) of E-VAC at each zone "Tested each E-VAC inlet for available flow rate SCFM. oTested pressure at each inlet in all critical care areas. oTested for flow rate and pressure drop with high volume demand on adjacent inlets "Tested each E- V AC inlet for proper function, identification, adaptation, and mechanical integrity. oIdentified leaking/malfunctioning inlets oIdentified inlets delivering substandard vacuum/flow rate "Tested all E-VAC zone valves for proper function, identification, and mechanical integrity "Checked E-VAC system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). "Checked for crossed lines. DENTAL VACUUM SYSTEM "Checked Dental Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). "Checked for crossed lines.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/DaVAMC552/DaVAMC552/VA25016Q0522/listing.html)
 
Document(s)
Attachment
 
File Name: VA250-16-Q-0522 VA250-16-Q-0522_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2936519&FileName=VA250-16-Q-0522-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2936519&FileName=VA250-16-Q-0522-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;Dayton VA Medcial Center;4100 West Third Street;Dayton, Ohio
Zip Code: 45428
 
Record
SN04220323-W 20160813/160811235519-94cda1d8d8242cf4b2d60541095f0e09 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.