SOURCES SOUGHT
Z -- USCG ACADEMY REPLACE POOL HVAC SYSTEM AT ROLAND HALL
- Notice Date
- 8/12/2016
- Notice Type
- Sources Sought
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Homeland Security, United States Coast Guard (USCG), Commanding Officer, USCG Civil Engineering Unit Providence, 475 Kilvert Street Suite 100, Warwick, Rhode Island, 02886-1379, United States
- ZIP Code
- 02886-1379
- Solicitation Number
- HSCGG1-16-S-ROLANDHVAC
- Archive Date
- 10/7/2016
- Point of Contact
- Jean M Bretz, Phone: (401)736-1765
- E-Mail Address
-
JEAN.M.BRETZ@USCG.MIL
(JEAN.M.BRETZ@USCG.MIL)
- Small Business Set-Aside
- N/A
- Description
- SOURCES SOUGHT: THIS IS ONLY A MARKET SURVEY FOR WRITTEN INFORMATION ONLY. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT WILL BE AWARDED FROM THIS ANNOUCEMENT. No reimbursement will be made for any costs associated with providing information in response to this announcement or any follow-up information requests. In order to protect the procurement integrity of any future procurement that may arise from this announcement, information regarding the technical point of contact will not be given and no appointments for presentations will be made. The U.S. Coast Guard is considering whether or not to set aside an acquisition for HUBZone Small Business concerns, Service-Disabled Veteran-Owned Small Business concerns (SDVOSB), 8(a) certified Small Business concerns, Woman-Owned Small Business concerns or Small Business concerns, or solicit Unrestricted. The applicable North American Industry Classification System (NAICS) code is 238220, with a small business size standard of $15 Million. The estimated value of the procurement is between $1,000,000 and $1,500,000. Performance and Payment bonds will be required. The U.S. Coast Guard is seeking Interested Vendors with successful past performance, current relevant experience, personnel/resources, equipment, and capability to perform the following work: General: Existing pool dehumidification equipment aged 20+ years, and the air distribution system is not adequate to maintain the air quality including proper ventilation during events, humidity and chloramines at pool water surface level. This has occasionally resulted increased health issues. The new HVAC system will improve the air quality with improved and increased equipment capacity, air changes, adequate ventilation during events, pool water surface heavy gas exhaust, lighting and controls improvements. Scope of Work includes the following key improvements: 1. Improved and larger natatorium unit 2. Ductwork and air distribution system 3. Pool hot water piping and pumps 4. Pool dehumidifier space re-heat piping and pumps 5. Existing mechanical room modifications to adopt new natatorium unit and future ease of access 6. Pool gutter piping replacement and new exhaust system 7. Pool deck drain system pipe lining 8. Existing building automation system improvements and re-commissioning 9. Electrical distribution system with new panel in the mechanical room 10. Pool area acoustical ceiling tiles replacement 11. Pool area lighting replacement with LED The anticipated schedule includes dehumidifier and duct work shop drawings being approved in late Jan 2017, with on-site construction beginning in April 2017 and being complete oob 28 July 2017. Award to completion is estimated at approximately 7 months. If your firm is interested in this requirement, and intends to submit an offer on this acquisition, please respond by email to jean.m.bretz@uscg.mil with "Sources Sought for Solicitation HSCGG1-16-S-ROLANDHVAC" in the subject line or by fax to (401) 736-1704. Your response MUST include the following: (a) a positive statement of your intent to submit a proposal for this solicitation as prime contractor; (b) a statement identifying your certified small business designation (if any); and, (c) evidence of prior successful SIMILAR HVAC work to include contract numbers, project titles, dollar amounts, points of contact and telephone numbers. Your response is required no later than 25 August 2016. All of the above must be submitted in sufficient detail for a decision to be made on an applicable set-aside.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/USCGCEUP/HSCGG1-16-S-ROLANDHVAC/listing.html)
- Place of Performance
- Address: USCG Academy, 15 Mohegan Ave., New London, Connecticut, 06320, United States
- Zip Code: 06320
- Zip Code: 06320
- Record
- SN04222055-W 20160814/160812235025-d422873286260a8417dbdb65c542a6df (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |