SOURCES SOUGHT
42 -- 600-675 GAL Water Bucket for Aerial Fire Surpression - Mandatory Company Information Attachment
- Notice Date
- 8/12/2016
- Notice Type
- Sources Sought
- NAICS
- 115310
— Support Activities for Forestry
- Contracting Office
- Department of the Army, National Guard Bureau, USPFO for Pennsylvania, Department of Veteran & Military Affairs, Annville, Pennsylvania, 17003-5003
- ZIP Code
- 17003-5003
- Solicitation Number
- 0010906640
- Archive Date
- 9/3/2016
- Point of Contact
- Raymond C Folweiler, Phone: 7178616872
- E-Mail Address
-
raymond.c.folweiler.mil@mail.mil
(raymond.c.folweiler.mil@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- The Company Information Attachment must be completed by all vendors interested SOURCES SOUGHT The Pennsylvania National Guard (PANG) United States Property Fiscal Office (USPFO) Purchasing and Contracting (P&C) is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in providing Two 600-675 GALLON WATER BUCKETS FOR AERIAL FIRE SURPRESSION. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 115310 Size Standard 17.5Million. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. The Government will not entertain any quotes or proposals The government will evaluate market information to ascertain potential market capacity to provide Two 600-675 GALLON WATER BUCKETS FOR AERIAL FIRE SURPRESSION that are in accordance with the Airworthiness Release (AWR -TTS59156C), published by AMCOM, Director of Aviation Engineering, dated 5 OCT 2015. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES, FURTHER SET-ASIDE UNDER AN SBA SOCIOECONOMIC PROGRAM, OR PROCURED THROUGH FULL AND OPEN COMPETITION. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. Submission Instructions: Interested parties who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice to include the completion of the Company Information attachment: by 1100AM 19AUG16 All responses under this Sources Sought Notice must be emailed to LTC Raymond C Folweiler IV Email: raymond.c.folweiler.mil@mail.mil. If you have any questions concerning this opportunity please contact: LTC Raymond C. Folweiler IV Email: raymond.c.folweiler.mil@mail.mil Scope, Requirements, and Objectives Scope: Water Buckets must have ‘plug-n-play' capabilities to assist helo operations with maximum effective firefighting capability. The bucket design must have the ability to pre-select the desired load which allows efficiency at both the dip site and over targeted site locations or multiple locations by the operator. Must have the capabilities to meet the need of emergency response situations. Crewmembers need to be able to quickly and efficiently use the equipment, as mission dictates. Low maintenance, durable material is a must. Requirements: The sources sought must be capable of providing Water Buckets that are in accordance with the Airworthiness Release (AWR -TTS59156C), published by AMCOM, Director of Aviation Engineering, dated 5 OCT 2015. The Water Buckets must have the following capabilities: 1) Manual load control 2) Valve actuations - unlimited (millisecond open & closure) 3) Load control options - unlimited load sheds (2% of load each) 4) Power fill capability 5) Holding Capacity: 600-675 Gallons 6) Empty weight of bucket: Between 280 lbs to 320 lbs 7) Gross weight at Maximum Load cannot exceed 5800 lbs 8) Overall Length cannot exceed 24'8" fts 9) Low Power Draw - less than 5 amps 10) 3 wire system for power 11) Low maintenance (no more than 4 blots to remove valve) 12) Durable material 13) Compatible with use for foam systems 14) Compatible with external power pack. (Allows for operations of bucket independent of aircraft power supply.) 15) Compatible to be loaded on a mobility cart if required to be ground handled to load site. 16) Color of bucket: Orange / Red 17) Internal fill system or compatible for internal fill system 18) User's manual 19) Collapsible design for storage Objective: Provide two 600-675 GALLON WATER BUCKETS FOR AERIAL FIRE SURPRESSION that are in accordance with the Airworthiness Release (AWR -TTS59156C), published by AMCOM, Director of Aviation Engineering, dated 5 OCT 2015.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA36/0010906640/listing.html)
- Place of Performance
- Address: Fort Indiantown Gap, Annville, Pennsylvania, 17003-5003, United States
- Zip Code: 17003-5003
- Zip Code: 17003-5003
- Record
- SN04222269-W 20160814/160812235210-95894b9a8ed0d66040b4a97bdfbcfdd1 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |