Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 26, 2016 FBO #5390
DOCUMENT

J -- ****RFI**** Respirator Fit Testing respirator fit testing and training in accordance with (OSHA), code of federal regulationsCFR 1910.134 635-17-1-6005-0004, VA256-16-N-1354 - Attachment

Notice Date
8/24/2016
 
Notice Type
Attachment
 
NAICS
621999 — All Other Miscellaneous Ambulatory Health Care Services
 
Contracting Office
Department of Veterans Affairs;ATTN: NCO 16 DIV I SER;1011 Honor Heights Drive;Muskogee OK 74401-1318
 
ZIP Code
74401-1318
 
Solicitation Number
VA25616N1354
 
Response Due
9/1/2016
 
Archive Date
10/31/2016
 
Point of Contact
Eric Tuck
 
E-Mail Address
uck@va.gov<br
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Network Contracting Office 16 is requesting information only, regarding respirator fit testing and training in accordance with the Occupational Safety and Health (OSHA), code of federal regulations CFR 1910.134 at the Oklahoma City VA Medical Center (OKC VAMC) employees are required to be included in a comprehensive respiratory protection program. See Statement of Work for specifics. Please communicate via email to eric.tuck@va.gov by Sept 01, 2016, 11:00 AM CST as to your company's ability to perform service per the attached Statement of Work. IMPORTANT NOTE: This is for Requesting For Information only no award will be made off of this RFI. DISCLAIMER: This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. If you choose not to participate, please respond accordantly. The Veterans Administration thanks you for your time and assistance related to this Request for Information. BRIEF SCOPE OF WORK (This is for information only) SERVICE In accordance with the Occupational Safety and Health (OSHA), code of federal regulations CFR 1910.134 some Oklahoma City VA Medical Center (OKC VAMC) employees are required to be included in a comprehensive respiratory protection program. Project Scope The contractor shall provide instructors for respirator fit testing and training for N95 respirators; and, training for Powered Air Purifying Respirators (PAPRs) for individuals who cannot be fitted with an N95. A minimum of one fit tester will be provided for Monday through Friday from 7am-5pm. The VA has the option of requesting a 2nd fit tester to work from 10am-2pm, or other time up to 4 hours during 7am-5pm, as needed. All work shall be conducted in accordance with Occupational Safety and Health (OSHA) respirator standard 29 CFR 1910.134. The fit testing schedule shall be in accordance with a schedule determined by the contract and based on employee availability. Testing days shall be scheduled for Monday through Friday from 7:00 am - 5:00 pm in order to give both shifts the opportunity to get fit tested. Fit tester shall follow OSHA requirements for fit testing and train each employee on the respirator they will be wearing. The contractor shall insure each employee has been medically cleared to wear a respirator within the past 6 months. Fit test will insure the following documentation: "The name of each employee's to be fit tested. "Service and Department "The date an employee's medical questionnaire was approved by the LHCP. "The type of respirator each employee was fitted with, results, fit tester identification and the date trained on the respirator. "Employee signature and the date of testing The contractor shall complete fit testing notification cards (supplied by the VA COR; this card lists the respirator the employee is to wear and the date fit testing was completed) and provide this card to each employee upon the completion of fit testing. On-site maintenance Location: Oklahoma City VAMC 921 N.E. 13th St., Oklahoma City, Ok 73104 Testing All testing materials will be supplied by the VA COR at the OKC Medical Center. The contractor shall keep the COR informed of level of supplies needed for the week. The contractor shall be required to periodically clean the fit testing equipment to ensure that saccharin is flowing through the nebulizer. IMPORTANTR NOTE: This RFI (Request for Information) is for information only; no award will be made off of this RFI
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/MuVAMC623/MuVAMC623/VA25616N1354/listing.html)
 
Document(s)
Attachment
 
File Name: VA256-16-N-1354 VA256-16-N-1354.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2963115&FileName=VA256-16-N-1354-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2963115&FileName=VA256-16-N-1354-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Oklahoma City VAMC;921 NE 13th Street;Oklahoma City, OK 73104-4208
Zip Code: 73104-4208
 
Record
SN04239982-W 20160826/160825000135-646cda4a320877fc434f349cce832383 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.