Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 27, 2016 FBO #5391
SOURCES SOUGHT

66 -- UV/VIS Spectrophotometer- Thermo Scientific Spectronic 200

Notice Date
8/25/2016
 
Notice Type
Sources Sought
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of the Air Force, Direct Reporting Units, USAF Academy - 10 CONS, 8110 Industrial Drive, Suite 200, USAF Academy, Colorado, 80840-2315, United States
 
ZIP Code
80840-2315
 
Solicitation Number
FA7000-16-T-0157
 
Archive Date
9/16/2016
 
Point of Contact
Bradford T Bygness, Phone: 7193334493, Susan Hashemi, Phone: 7193338059
 
E-Mail Address
bradford.bygness@us.af.mil, susan.hashemi@us.af.mil
(bradford.bygness@us.af.mil, susan.hashemi@us.af.mil)
 
Small Business Set-Aside
N/A
 
Description
This announcement serves as a Sources Sought Synopsis issued for the purpose of market research in accordance with Federal Acquisition Regulation (FAR) Part 10 for an upcoming acquisition at the United States Air Force Academy. This sources sought is issued solely for information and planning purposes and does not constitute a solicitation. For the purpose of this acquisition, the North American Industry Classification System Code (NAICS) is 334516 and the size standard in number of employees is 1000. The purpose of this notice is to identify companies capable and qualified to provide 20 new UV/VIS Spectrophotometer with the stated specifications to the U.S. Air Force Academy. All businesses capable of providing the spectrophotometer are invited to respond. Interested small business vendors must reference their 8(a), HUB Zone, Women-owned, or Service Disabled Veteran status, if applicable. This will be a Brand Name or Equal acquisition and a firm fixed price contract is anticipated to be awarded. The UV/VIS 20 Spectrophotometer consists of the following salient characteristics: Item No. 0001 (20 Each) UV/VIS Spectrophotometer- Thermo Scientific Spectronic 200, US Power Cord (Simple and routine application for teaching) Equal to or better than the following characteristics: · Accuracy (Photometric): ±0.01A at 0.3A; ±0.05A at 1.0A (SPECTRONIC standard filters measured at 590nm) · Beam Geometry: Single Beam · Compartments: Removable, washable sample compartment · Connections: USB-B for a connection to a remote computerUSB-A for connection to a printer or USB memory device · Container Type: Single cell holder for square cuvettes and for test tubes · Data Interval: 0.5 nm actual; 1 nm display under local control · Data Interval for Scanning: 1 nm on-board, 0.5 nm under computer control · Depth (English): 11.8 in. · Description: SPECTRONIC 200E, US Power Cord · Detector Type: 2048 element CCD · Display: Color graphical TFT LCD, 3.5 in. diagonal · Display Range: -0.3A - 2.5A; 0 - 125%T · Electrical Requirements: Selected automatically, 100/240V 50/60Hz · Height (English): 3.6 in. · Includes: Two Cuvet Racks; Ten 1cm plastic cuvets · Interface: USB-B; USB-A · Keypad: Sealed tactile rubber · Lamp: Tungsten-halogen (typical lifetime 1000 hrs) · Languages: English, Spanish, French, German, Italian, Chinese, Japanese, Korean, Thai · Measurement Range: -0.3 to 2.0A · Optical Design: Single Beam · Photometric Accuracy Instrument: ±0.01A at 0.3A; ±0.05A at 1.0A(SPECTRONIC standard filters measured at 590 nm) · Photometric Readout: ABS, %T, Concentration (standard or custom units) · Photometric Repeatability: ±0.03A at 0.3A · Printer: External printer support: Epson TM-T88V · Range (Photometric): -0.3 to 2.5Å · Spectral Bandwidth: <4 nm · Stray Light: <0.2%T (with SPECTRONIC standard SRM 400 filter) · Wavelength Accuracy: ±2 nm · Wavelength Range: 340 - 1,000 nm · Wavelength Repeatability: ±1 nm · Weight (English): 9.7 lb. · Width (English): 15.3 in. Item No. 0002 Unique item identifier label IAW DFARS 252.211-7003 Item Unique Identification and Valuation All potential offerors are reminded, in accordance with FAR 52.212-4(t)(4), System for Award Management, lack of registration in the System for Award Management (SAM) will make an offeror ineligible for contract award. Offerors and Contractors may obtain information on registration and annual confirmation requirements via SAM accessed through https://www.acquisition.gov. Any information provided by industry to the Government as a result of this sources sought synopsis is voluntary. The Government will not pay for any information submitted in response to this sources sought synopsis. Delivery is FOB Destination to USAF Academy, CO 80840. The specifications for this requirement are included. Comments and/or suggestions on the specifications are encouraged and can be included in your capabilities package. Interested businesses shall provide the following information: 1. Company name, mailing address, cage code, DUNS number, point of contact, telephone number and email address. 2. Business size status, e.g., 8(a), HUBZone, Woman Owned or Service Disabled Veteran-Owned, small business, large business, etc. 3. Appropriate written information and/or data supporting your capability to provide the stated UV/VIS Spectrophotometer. 4. Answers to the following questions: a. How long have you been in business? b. Have you provided this item in the past? c. Are you a manufacturer or supplier of the item? d. What is your lead-time for delivery? e. Have you ever performed Government contracts? f. What are your payment/discount terms? Do you offer an educational discount to universities? g. If you require different terms and conditions than those normally used by the Government, what are your commercial terms and conditions? Please feel free to provide a copy of your terms and conditions for this type of work. h. Where is the spectrometer manufactured? i. Where are the components manufactured? j. What is your estimated cost for this requirement? You will not be held to this price, it is only for market research purposes. k. Are operating and maintenance manuals, or any other items, included? l. Do you offer warranty coverage? If yes, provide further details. m. Is the product Buy American compliant IAW DFARS 252.225-7001? n. Is the product considered commercially available off-the-shelf IAW FAR 2.101 and FAR 12.103? If not, is the product considered commercial? This notice is designed to locate responsible sources that have an interest, and have the ability to supply the item described herein. If your firm is capable and qualified to provide UV/VIS Spectrophotometer, send the required response in writing to the primary point of contact indicated within this announcement. Responses are due no later than 1 September 2016, 10:00 a.m. Mountain time by e-mail. Questions and responses should be addressed to the primary contact, Brad Bygness, Contracting Specialist, 719-333-4493 or bradford.bygness@us.af.mil or the alternate point of contact, Susan Hashemi, Contracting Officer, 719-333-8059 or Susan.hashemi@us.af.mil.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/DRU/10ABWLGC/FA7000-16-T-0157/listing.html)
 
Place of Performance
Address: USAF Academy, Colorado, 80840, United States
Zip Code: 80840
 
Record
SN04241724-W 20160827/160826000228-040c07c4a265826998915e48db89cf82 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.