Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 01, 2016 FBO #5396
SOURCES SOUGHT

66 -- Laser Capture Microdissection System

Notice Date
8/30/2016
 
Notice Type
Sources Sought
 
NAICS
333314 — Optical Instrument and Lens Manufacturing
 
Contracting Office
Department of Health and Human Services, National Institutes of Health, National Institute on Drug Abuse, 6001 Executive Boulevard, Room 3155, MSC 9593, Bethesda, Maryland, 20892, United States
 
ZIP Code
20892
 
Solicitation Number
HHS-NIH-NIDA-SSSA-SS-2016-564
 
Archive Date
9/20/2016
 
Point of Contact
Stacey M Polk,
 
E-Mail Address
spolk@nida.nih.gov
(spolk@nida.nih.gov)
 
Small Business Set-Aside
N/A
 
Description
This is a Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. This notice is issued to help determine the availability of qualified companies technically capable of meeting the Government requirement and to determine the method of acquisition. It is not to be construed as a commitment by the Government to issue a solicitation or ultimately award a contract. Responses will not be considered as proposals or quotes. No award will be made as a result of this notice. The Government will NOT be responsible for any costs incurred by the respondents to this notice. This notice is strictly for research and information purposes only. Background: The mission of The National Center for Advancing Translational Sciences (NCATS) is to apply the tools of small molecule screening and discovery to the development of chemical probe research tools, for use in the study of protein and cell functions, and biological processes relevant to physiology and disease. This request will enable NCATS and the Bioprinting group to optimize Tissue Engineering techniques by providing a means to evaluate cell morphology in engineered tissues. This will ultimately increase the capability to optimize biochemical, cellular and model organism-based assays submitted by the biomedical research community; and perform automated high-throughput screening (HTS) and high-content screening (HCS). The Probe Development group is part of The National Center for Advancing Translational Sciences (NCATS). The Probe Development group utilizes 3D bioprinting techniques. This approach can provide data more relevant to the whole body response than traditional studies which use two dimensional cell cultures. Initial research is being performed to advance fabrication techniques and protocols. Purpose and Objectives: The purpose of this acquisition is to purchase a Laser Capture Microdissection System to generate tissues which will be used to perform studies into causes and treatments of various diseases. Scope of Work Brand Name OR Equal Leica LMD6 Laser Capture Microdissection System The following parts are required: 100 LMD6 (LED, mot.Z) No : 11888868 200 CTR6 LED No : 11888873 300 Top LMD6/7, 5­fold, Fluo, 7xM25, mot. No : 11888887 400 External light source EL 6000 No : 11504115 500 Lightguide coupler 1" No : 11504117 600 Liquid Light Guide for EL6000, 2m No : 11504116 700 Filter system LMD­BGR No : 11513911 800 Condenser DIC for LMD No : 11888830 900 LMD Scanning stage No : 11888449 1000 Advanced XYZ­module LX No : 11888425 1100 Smart Move for DM/DMI Series No : 11505180 1200 LCC Module LMD No : 11505285 1300 Obj. UVI 5x/0.12 Microdissection No : 11518146 1400 Obj. UVI 10x/0.25 Microdissection No : 11518147 1500 Obj. HC PL FL L 20x/0.40 CORR No : 11506242 1600 Obj. HCX PL FLUOTAR L 40x/0.60 CORR XT No : 11506208 1700 Obj. HC PL FLUOTAR L 63x/0.70 CORR XT No : 11506222 1800 ICT­condenser prism K3 No : 11555017 1900 ICT condenser prism K6 No : 11521521 2000 ICT condenser prism K7 No : 11521522 2100 IC­Prism A for objective No : 11555006 2200 IC­Prism C for objective No : 11555009 2300 Filter system analyzer size 'k' No : 11513900 2400 Wacom Cintiq 22HD Pen Display No : 8102847 2500 17" Monitor No : 8014894 2600 Keyboard US USB Hub No : 11600220 2700 LMD CC7000 camera No : 11501478 2800 C­Mount HC 0.55x No : 11541544 2900 Tube adapter incl. 1 docu. port No : 11505161 3000 Mag.Changer, 2x, in fluo cube size k, No : 11501467 3100 PEN Membrane Slide(4µm),glass,50 slides No : 11600288 3200 Petri dishes w PEN­membrane sterile 20pc No : 11505172 Minimum Requirements: 1.The system must be capable of laser microdissection of tissue sections to isolate and harvest single cells or entire areas of tissue. 2.The system must use a gravity based specimen collection to minimize cross contamination, and to enable sample collection from multiple tissue sites into one tube and to enable the sample to fall directly into lysis buffer or preservation solution to preserve the desiccate. 3.The system must use standard pcr tubes as capture devices. 4.The system must implement the following features: a.actively cut the sample, in real-time, based on direct digital pen input drawn onto the monitor b.automatically batch cut samples based on regions of interest drawn by the operator c.use high-precision optics to steer the laser beam along the desired cut line on the tissue with prisms for extremely precise and fast laser control and cutting (accuracy of laser movement down to at least 0.007 um); and provide best view for convenient movie documentation. d.fully adjustable laser settings, including adjustable pulse rate and laser width e.ability to continuously cut in X-Y while moving the sample in Z to allow very thick tissue to be dissected and cut accurately f.software module that allows for automatic Z movement of the objective so that it doesn't interfere with the high sides of a petri dish g.UV offset for laser beam to be automatically saved with each objective; microscope should adjust laser focus based on individual objective compensation value h.high UV throughput LMD objectives for easy laser transmission i.encoded stage for highly precise sample movement to preserve any drawn regions of interest by eliminating any stage hysteresis k.5x objective w/ minimum 0.12 NA, 10x objective w/ minimum 0.3 NA, 20x objective w/ minimum 0.4 NA and 6.9mm of working distance, 40x objective with minimum 0.6 NA and between 1.9 and 3.3 mm working distance, and 63x objective with minimum 0.7 NA and between 1.6 and 2.8 mm working distance l.objectives must use DIC m.microscope must be fluorescence capable and allow cutting in real-time during fluorescence visualization n.microscope stage must come with adapters that interface with petri dishes that allow for dissection of live cells in solution o.camera with 1.2 megapixels of resolution that works over high-speed, real time GigE connection p.355nm wavelength laser with a pulse frequency of 80 Hz, pulse length of less than 4 ns, and max pulse energy of 70 uJ Installation:The Contractor shall install the entire system/equipment. The Contractor shall provide qualified personnel to perform the installation, supervise the installation, and perform all activities necessary to ensure the system/equipment are 100% functional and meets original manufactures specifications. Capability statement /information sought. Contractors that believe they possess the ability to provide the requirement should submit documentation of their ability to meet each of the project requirements to the Contract Specialist. The response should directly and specifically state in the, capabilities statement, which project requirements you can supply. Contractors must also provide their Company Name, DUNS Number, Physical Address, Point of Contact, and Size and Type of Business (e.g., 8(a), HubZone, etc.) pursuant to the applicable NAICS code and any other information that may be helpful in developing or finalizing the acquisition requirements. The information submitted must be must be in an outline format that addresses each of the elements of the project requirement and in the capability statement /information sought paragraphs stated herein. The response must include the respondents' technical and administrative points of contact, including names, titles, addresses, telephone and fax numbers, and e-mail addresses. All responses (capability statements) sent in response to this Sources Sought Notice must be submitted electronically (via e-mail) to the Contract Specialist. Facsimile responses are NOT accepted. The response must be submitted to Stacey Polk, Contract Specialist at spolk@nida.nih.gov. The response must be received on or before September 5, 2016, 2016, 2 pm Eastern Standard Time. "Disclaimer and Important Notes: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality: No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s)."
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/NIH/NIDA-01/HHS-NIH-NIDA-SSSA-SS-2016-564/listing.html)
 
Place of Performance
Address: National Institutes of Health, 9800 Medical Center Drive, Bethesda, Maryland, 20850, United States
Zip Code: 20850
 
Record
SN04247800-W 20160901/160831000055-23b5e56dc589f7d6ddafa284e71f176f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.