DOCUMENT
65 -- (C)(660) Vigilance II Monitors - Attachment
- Notice Date
- 9/15/2016
- Notice Type
- Attachment
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office;NCO 19;4100 E. Mississippi Avenue, Suite 900;Glendale CO 80246
- ZIP Code
- 80246
- Solicitation Number
- VA25916Q0573
- Response Due
- 9/20/2016
- Archive Date
- 10/5/2016
- Point of Contact
- Brooke Barker
- Small Business Set-Aside
- N/A
- Description
- This is a SOURCES SOUGHT request only. This is NOT a solicitation for proposals, proposal abstracts, or quotations. This notice is published for market research purposes only. This notice is open to qualified business sources of all sizes. Information is sought regarding: 1.The availability and capability of all qualified business sources; 2.Whether qualified business sources are small businesses, service-disabled small businesses, veteran-owned small businesses, women-owned small businesses, small disadvantaged businesses or large businesses; 3.If the items are available via VA NAC, GSA Advantage, and/or open market; 4.Size classification relative to the North American Industry Classification System (NAICS) code 334510 for the proposed acquisition. Requests for a solicitation will not receive a response. The purpose of this sources sought synopsis is to gain knowledge of potential qualified sources. The Government is seeking potential sources for Vigilance II Cardiac Patient Monitor or equal products. The equal item(s) shall meet or exceed the required item(s). Equal item(s): submit detailed documentation stating how the product(s) is/are compatible/interfaces with the current Swan-Ganz Pulmonary Artery Catheters and Edwards Advanced Technology Catheters (both stated catheters are currently in use) and how the item(s) meet or exceed each brand name item. All items shall be in a new, never used condition. Required items: 1.VIG2 - Vigilance II Monitor (2 each) a.Hemodynamic monitoring system with continuous CO, SvO2, EDV, RVEF, SVR, and SV output b.Continuous SvO2 with use of PreSep oximetry catheter c.Interface with bedside monitor for the display of additional measured and derived parameters such as continuous SVR, DO2, DO2I, VO2, VO2I, O2ER, and VQI d.Can be used with Swan-Ganz Pulmonary Artery Catheters e.Can be used with Edwards Advanced Technology Catheters 2.OM2 - Oximetry Optical Module (2 each) 3.70CC2 - Cable CCO Catheter Interface (2 each) 4.VIG2AP - Vigilance II Adapter Plate (2 each) 5.VIG2S - VIG2 Roll Stand (2 each)
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/VA25916Q0573/listing.html)
- Document(s)
- Attachment
- File Name: VA259-16-Q-0573 VA259-16-Q-0573.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3005408&FileName=VA259-16-Q-0573-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3005408&FileName=VA259-16-Q-0573-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA259-16-Q-0573 VA259-16-Q-0573.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3005408&FileName=VA259-16-Q-0573-000.docx)
- Place of Performance
- Address: Department of Veterans Affairs;Salt Lake VA Medical Center;500 Foothill Drive;warehouse;Salt Lake City, UT 84148
- Zip Code: 84148
- Zip Code: 84148
- Record
- SN04274490-W 20160917/160916000651-8ae4c505c7f5c37b97c799e57db9686d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |