MODIFICATION
61 -- Aircraft power unit generators
- Notice Date
- 9/23/2016
- Notice Type
- Modification/Amendment
- NAICS
- 335312
— Motor and Generator Manufacturing
- Contracting Office
- Department of the Army, National Guard Bureau, 129 RQW, BASE CONTRACTING, PO BOX 103/STOP 25, MOFFETT FEDERAL AIRFIELD, California, 94035
- ZIP Code
- 94035
- Solicitation Number
- F8A2HM6195AW01_AircraftPowerUnits
- Archive Date
- 10/11/2016
- Point of Contact
- Bardia Barmaki, Phone: 6506039274
- E-Mail Address
-
bardia.barmaki.mil@mail.mil
(bardia.barmaki.mil@mail.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- THESE ARE CHANGES THAT ARE MADE TO THE DESCRIPTION TO BETTER UNDERSTAND THE REQUIREMENT. Provide two (2) total, aircraft power generation units for installation in Composite Aircraft Maintenance Hangar to support power delivery to one (1) MC-130P and two (2) HH-60G aircraft. Generators must be capable of delivering 3-phase, 400 Hz, 115 VAC and 28 VDC with capacity of 90 kVA. Contractor must deliver and connect units to existing electrical outlets within the hangar. Specific performance specifications for generator's as follows: Generator #1: -90kVA single output 400hz Solid State power unit. -INPUT: 3-phase 60Hz 480 VAC / rated for less than 5% input THD -OUTPUT: 3-phase 400 Hz 115 VAC / with 28VDC E&F control -OUTPUT CABLE : 1x 35-foot 260amp rated banded cable with aircraft plug-end. Generator #2: -90Kva Dual outputs (each output rated for 45kVA) 400hz Power unit -INPUT: 3-phase 60 Hz 480 VAC/ rated for less than 5% input THD -OUTPUTS: TWO (2) - 3-phase 400 Hz 115 VAC, / with 28VDC E&F Control rated at 45kVA each. -OUTPUT CABLES: Two (2) 55-foot 260amp rated banded cable with aircraft plug-end Dimensions NTE 30" deep by 25" wide by 52" height. Solid State is required. There is no requirement for the units to be mobile. Provide two (2) total, aircraft power generation units for installation in Composite Aircraft Maintenance Hangar to support power delivery to one (1) MC-130P and two (2) HH-60G aircraft. Generators must be capable of delivering 3-phase, 400 Hz, 115 VAC and 28 VDC with capacity of 90 kVA. Contractor must deliver and connect units to existing electrical outlets within the hangar. Specific performance specifications for generator's as follows: There is no requirement for the units to be mobile. Installation is not required.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA04-3/F8A2HM6195AW01_AircraftPowerUnits/listing.html)
- Place of Performance
- Address: 129th RQW/MXG, Macon Rd, Moffett Field, California, 94035, United States
- Zip Code: 94035
- Zip Code: 94035
- Record
- SN04285343-W 20160925/160923234327-c3c77efd99422f8174c66a2d56073f05 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |