Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 28, 2016 FBO #5423
DOCUMENT

J -- Generator Maint 678-17-1-620-0013 - Attachment

Notice Date
9/26/2016
 
Notice Type
Attachment
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
Department of Veterans Affairs;VISN/18PHX;777 E. Missouri, Suite 300;Phoenix AZ 85014
 
ZIP Code
85014
 
Solicitation Number
VA25816Q1020
 
Response Due
9/28/2016
 
Archive Date
11/27/2016
 
Point of Contact
Gary.Smith4@va.gov
 
E-Mail Address
GARY.SMITH4@VA.GOV
(GARY.SMITH4@VA.GOV)
 
Small Business Set-Aside
Total Small Business
 
Description
D.1 SPECIAL CONTRACT REQUIREMENTS 1. SCOPE. Contractor shall maintain in good operating condition the listed equipment in the Contract, SECTION B, SUPPLIES AND SERVICES/PRICES. The equipment is located at the Southern Arizona VA Health Care System (SAVAHCS) 3601 S. 6th Ave Tucson, AZ 85723 and the Phoenix VA Health Care System (PVAHCS) 650 E. Indian School Road 85012. The contractor will provide comprehensive Annual and Quarterly Scheduled Maintenance and Testing for station emergency and standby generators (diesel fueled). This maintenance will include Operational Inspection Services (OIS), Load Bank Testing - Level I Annual Two-Hour and Load Bank Testing - Level I Triennial Four-Hour and repair services (at an additional cost to the facility), for the equipment listed in 2.15, Equipment listing for this contract. All testing is to be performed in accordance with The Joint Commission standards, as applicable. 2. DESCRIPTION OF SERVICES. 2.1. COMPLIANCE. The Contractor shall be fully responsible for compliance with all VA, local, state, and Federal environmental/occupational safety laws, rules and regulations. The Contractor shall follow life and safety codes, and take necessary actions to avoid conditions that may be hazardous to the health and safety of hospital personnel and patients. The Contractor is responsible for meeting all applicable OSHA and VA guidelines for safe working processes; example: lockout/tag-out. All work for the duration of the contract shall be performed by certified trained technicians. 2.2. WORKING HOURS. Preventive maintenance work shall be performed on weekdays, excluding Federal holidays, during the hospital's regular weekday working hours of 8:00 a.m. - 5:00 p.m. Federal holidays observed may be exchanged for Contractor observed day, only on a one-for-one basis, requested by the Contractor and subject to approval by the Contracting Officer. 2.3 SERVICE CALLS; NOTIFICATION AND RESPONSE TIME. The Contractor must provide an emergency telephone number for purposes of accepting service calls, available 24 hours a day, 7 days a week. Maintenance & Operations at (520) 792-1450 ext. 6640 will notify the Contractor of equipment malfunction, the nature of the malfunction, and the availability of the equipment. VA is responsible to make the equipment available. In an emergency, Maintenance & Operation will inform the Contractor of the delay and schedule a new availability time. The Contractor must acknowledge receipt of notification by calling Maintenance & Operation within two hours of the originating call. The Contractor shall be on-site to make repairs within two (2) hours of the originating call. The Contractor shall restore the equipment to full performance within 24 hours of the originating call and/or have the capability to provide a portable emergency generator of equal capacity. Charges to the VA for generator rental shall originate only upon prior approval being granted by the Chief Engineer or his designee. 2.4. PARTS. This Contract, and the applicable firm-fixed prices listed in the Contract, SECTION B, SUPPLIES OR SERVICES AND PRICES, includes all necessary replacement parts. Full performance is defined as; all defective parts have been replaced with parts equivalent to or better than the original parts and meets or exceeds the manufacturer's original performance specifications. The Contractor is responsible to have in-stock or have the ability to provide all necessary parts, components, assemblies, modules and equipment to restore any malfunctioning equipment to full performance within 24 hours of the originating call or provide a rental portable emergency generator of equal capacity to stand by until the above conditions are met. The Contractor shall supply all preventative maintenance parts, (oil, oil filters, air filters, fuel filters and antifreeze), at no additional cost to the facility, cleaning supplies and tools required for preventive maintenance and, as a result of normal wear and tear, restore equipment to full performance. NOTE: Parts, considered to be the manufacturer's recommended parts, are to be replaced at the facilities expense in the course of a recommended preventive maintenance inspection. All parts shall meet the original manufacturer's design specification. Lubricants shall meet manufacturer's specifications and have prior VA approval for use. Contractor shall turn over to the VA all non-repairable parts. Any reconditioned components utilized to make repairs must meet manufacturer's specifications, be noted on the service slip and have a 90 day warranty. Use of a reconditioned part may only be used with the concurrence and approval of the VA. Each facility shall have the option of replacing recommended parts at their expense utilizing their maintenance staff. 2.5. CONFIRMATION OF REPAIR WORK. All completed repairs must be confirmed and approved by VA Maintenance & Operation during regular hospital working hours, 8:00 A.M. - 5:00 P.M., Monday through Friday excluding Federal Holidays. After regular working hours, weekends, and holidays, Maintenance & Operation may approve equipment available for use after repairs have been made. The COTR will confirm and approve all after-hour emergency repairs during the next normal working day. 2.6. MAINTENANCE, INSPECTIONS, AND TESTS. Inspections will be scheduled during the timeframe of the Contract year. Prior to scheduled month of service, the Contractor will provide Maintenance & Operations a schedule of the weekdays this service is to be performed, for this approval. Maintenance & Operations shall have the authority to reschedule this service within twenty-four (24) hours of scheduled time due to emergency and/or prior weather situations. Contractor shall inspect, adjust, lubricate, clean, repair and test to ensure safe reliable service within all tolerances as required by Manufacturer's Specifications. All parts used shall be of the original manufacturer's design and specification or equal thereto. All malfunctioning parts shall be replaced at the facilities expense and approval immediately to prevent undue down time and to ensure safe operation. NOTE: Upon discovery of malfunctioning part, Maintenance & Operations staff shall be immediately notified for approval of repairs 2.7. PREVENTIVE MAINTENANCE SERVICE. Preventive maintenance inspections shall be performed as necessary to meet manufacturer/factory specifications. Oil, oil filters, air filters, fuel filters and antifreeze shall be supplied by the Contractor at no additional charge to the facility. 2.8. PERFORMANCE AND TESTING. After completion of maintenance, the system shall be operated by the Contractor to ensure all components meet required standards as outlined in manufacturer's specifications. All components and controls shall be checked and adjusted if necessary or applicable. 2.9. DOCUMENTATION OF SERVICES PERFORMED. At the conclusion of the inspection period, the Contractor shall submit electronically within 10 working days a report to Maintenance & Operations indicating the elements of the inspection performed, findings, and recommendations if applicable. This report shall be submitted in the form of a checklist or manufacturer performance service ticket, provided all requested information is supplied. All repair work shall be documented when service is completed. The repairman must indicate on his repair ticket the specific action taken, all parts replaced, hours of labor required, and travel time. The equipment serviced must be identified clearly by name and location. Upon completion of service, Maintenance & Operations will sign the service ticket. 2.10. CLEANUP. The Contractor shall be responsible for cleaning the work area and equipment upon completion of work. All accumulated rubbish shall be removed. 2.11. SPECIAL TOOLS. The Contractor shall provide all tools, testing equipment for disassembly, assembly, adjustment, calibrating and other work as required for the performance of this Contract. 2.12. OVER AND ABOVE REPAIR. Upon discovery of a malfunctioning part the Contractor shall immediately notify Maintenance & Operations staff. The repair job shall not be initiated until approval is obtained from the Contracting Officer and appropriate Maintenance & Operations staff. Charges for repair, labor and parts shall originate only when required and upon prior approval being granted by the Contracting Officer. At the VA's option the Contractor may be requested to provide a price quotation for the repair job. The VA has sole discretion to select the Contractor who will provide these repair services and they will be ordered as a separate action (not as a part of this contract). 2.13. CONTRACTOR EMPLOYEES. Contractor personnel shall present a neat appearance and be easily recognized as Contractor employees. Example: wearing of distinctive clothing such as uniform, badges, patches, etc. 2.14. ESCORT AND SAVAHCS CHECK-IN. All Contractor personnel working on-site at the SAVAHCS facility shall check in and out at the Maintenance & Operations Administrative area located in Building 2 Room OB26A-2. Check-in procedures require receiving a temporary badge and completing the necessary information on the vendor sign-in sheet. Access to work areas and performance monitoring will be provided by VA Maintenance & Operations personnel. After-hours response will be monitored by VA Utilities Systems Repairer/Operator (USRO) ext. 6684 or the VA Police ext. 6513. 2.15. Equipment Listing for this Contract: Southern Arizona VA Health Care System, Tucson, Arizona 1.Cummins Onan 750DFJA S/N D930505096 (B40, Gen40-1) 2.Cummins Onan 1250 KW DFLC-5588132 S/N B030466913 (B40, Gen40-2) 3.Generac 500KW 2798020100 S/N 2070779 (B80) 4.Kohler 135KW CUMMIN135RE0ZJZ S/N2094237 (B17) 5.Cummins 450KW DFEC5703566 S/N B597477 (B60) 6.Cummins MDL 80KW DSFAE-5937495 S/NJ070121222 (B90) 7.Cummins MDL 350KW DFEG-5788041 S/N D070049179 (B78) 8.Cummins MDL 1250KW DQGAA-5773152 S/N C070032091 (B40. Gen40-3) 9.Cummins MDL 200KW ASGAE-1338693 S/N J130577454 (B5) 10.MQ Power Corp. Portable Generator Trailer 25 KVA DCA25SS1U3 S/N8600457 11.MQ Power Corp. Portable Generator Trailer 45 KVA DCA45US12 S/N8202360 12.MQ Power Corp. Portable Generator Trailer 45 KVA DCA45US12 S/N8600361 13.MQ Power Corp. Portable Generator Trailer 85 KVA DCA85USJ2 S/N8401258 14.MQ Power Corp. Portable Generator Trailer 85 KVA DCA85USJ2 S/N8401261 15.MQ Power Corp. Portable Generator Trailer 150 KVA DCA150USJ2 S/N8600467 Phoenix VA Health Care System (PVAHCS) 650 E. Indian School Road 85012 1.DMT750kW DMT750D97-205050-1 Bldg. 13 2.DMT750kW DMT750D97-205050-2 Bldg. 13 3.Caterpillar350kW D3406 9DR049 Bldg. 13 4.Kohler350kW 350REOZV2066327 Bldg. 2 5.Cummins 100kW 6BTA5-G446716166 Bldg. 20 6.Cummins 100kW QSB5-65NR346959456 Bldg. 20 7.Caterpillar1000kW SR5 G1EO1373 Bldg. 21 8.Kohler1500kW 1500REOZDC2248136 Bldg. 13 9.John Deere275kW 6081HF070RG6081H294304 Bldg. 20 10.Kohler1500kW 1500REOZDG 3029689 Bldg. 13 11.Paramac 100kW GRW120PEE2537072 Bldg. 20
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PhVAMC/HMC/VA25816Q1020/listing.html)
 
Document(s)
Attachment
 
File Name: VA258-16-Q-1020 VA258-16-Q-1020.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3027369&FileName=VA258-16-Q-1020-002.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3027369&FileName=VA258-16-Q-1020-002.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04287167-W 20160928/160926234219-24148b00cb26a4775ad5826ba9852dfb (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.