Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 05, 2016 FBO #5430
DOCUMENT

65 -- FY17 WOUND VAC EQUIPMENT RENTALS V797D-30198 - Attachment

Notice Date
10/3/2016
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 20;5115 NE 82nd Ave, Suite 102;Vancouver WA 98662
 
ZIP Code
98662
 
Solicitation Number
VA26016Q1022
 
Response Due
10/11/2016
 
Archive Date
11/10/2016
 
Point of Contact
Brittany Ronhaar
 
Small Business Set-Aside
N/A
 
Description
Line Item 1 Negative Pressure Wound Vac. Therapy System Manufacturer: Product Number: VAC ULTA (or Equal) Quoting on: Manufacturer:___________________ Brand Name:____________________ Model Number:_________________ Salient Characteristics: Wound Vac's Units We would like equivalent needs for brand name or equal to V.A.C.Ulta Therapy unit by KINETIC CONCEPTS INC, vendor. This pump needs to be designed to provide negative wound therapy which consists of: 1.Continuous or Intermittent negative pressure 2.Creates healing throughout wound 3.Delayed Primary intention 4.Reduces edemas 5.Removes exudate and/or infections material The pump must be able to perform these functions: 1)Integrated wound system that provides therapy 2)Additional therapeutic selections that allow for wound healing customization 3)Offering a flexible approach to wound care 4)Offers three therapies in one easy-to-use unit. 5)Integrated wound therapy provides NPWT with an instillation option. 6)Compatible with all the V.A.C. Dressings that: a.Distributes negative pressure to individual sensing lumens b.Helps reduce tubing blocks and false alarms through enhanced fluid dynamics c.Enhances patient comfort with a low profile design 7)Negative pressure wound therapy system that integrates a wound management system plus additional therapeutic selections that allow for wound healing customization, offering a flexible approach to wound care. ? Specifications needed for negative pressure wound therapy system are as follows: 1)Portable 2)Leak Detector offering instant feedback to help identify leaks. 3)Canisters to collect exudate 4)Dressings specifically designed to: 1)Promote cellular healing actively. 2)Pre-cut perforated design to be easily torn - no scissors needed. 5)Technology that provides continuous feedback for enhanced negative pressure accuracy 6)Weight: 3.35kg (7.4 lbs. with a 500cc empty canister and no solution bag) 7)Dimensions: 217mm x 260mm x 191mm (8.55in x 10.25in X 7.5in) 8)Electrical Data (Power Supply) 9)Voltage 100 - 240 VAC 10)Frequency 50Hz - 60Hz 11)Power 60W 12)IEC Classification 13)Continuous Operation 14)Type BF Applied Part 15)Class II or internally powered equipment 16)IPX1 17)Power Supply 18)Class I Equipment 19)Ordinary Equipment 1)Battery Type: Custom Lithium Battery 2)Battery Life: Approximately 6 hours 3)Battery Recharge: Approximately 4 hours 4)Environmental Conditions: Transport and Storage Temperature Range -20 ºC to +60 ºC (-4 °F to 140 °F) Operational Temperature Range +10 ºC to +30 ºC (50 ºF to 86 °F) Relative Humidity Range l0% to 85% non-condensing Barometric pressure Range 700 hPa to 1060 hPa
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/48c54b10cf75dc57c0f8a1f39fd8ab34)
 
Document(s)
Attachment
 
File Name: VA260-16-Q-1022 VA260-16-Q-1022_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3038434&FileName=VA260-16-Q-1022-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3038434&FileName=VA260-16-Q-1022-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04295928-W 20161005/161003234102-48c54b10cf75dc57c0f8a1f39fd8ab34 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers